All categories
Earth-Leakage Circuit Breakers (ELCB)
All categories
Earth-Leakage Circuit Breakers (ELCB)
ABB 2CSF204201R3630 is a Residual Current Circuit Breaker (RCCB) designed with screw-clamp connections and a rated current of 63A. It features a Type A design and is suitable for DIN rail mounting. This RCCB has a net width for 4-poles (4P) and is specified with a control voltage for AC applications. The rated insulation voltage (Ui) is noted as 69 mm, which appears to be an error in the provided data, as voltage is not measured in millimeters. The supply voltage is designed for 400 V applications, and the device is capable of 10000 operations. It includes a number of Normally Closed (NC) circuits and is rated for 20000 operations for its analog outputs. The color specification is listed as 300mA, which seems to be a misplacement of information, as color typically does not have an electrical value.
Quick Quote
ABB 2CSF202201R3400 is a Residual Current Circuit Breaker (RCCB) designed with screw-clamp connections and a rated current of 40A. It features a type A design and is suitable for DIN rail mounting. This RCCB has a rated insulation voltage (Ui) of 69 mm and operates with a control voltage that accommodates 400 V. It is equipped to handle a supply voltage for up to 10,000 operations and has a durability for analog outputs up to 20,000 operations. The device is structured with 2-poles (2P) and has a net width corresponding to the standard 85 mm communication protocol, while the rated impulse voltage (Uimp) stands at 35 mm. The color specification for this model is 300mA, indicating its operational capacity in terms of residual current detection.
Quick Quote
Schneider Electric M9D11620 is a Residual Current Circuit Breaker with Overload protection (RCBO) / Earth Leakage Circuit Breaker (ELCB) from the N40 Vigi sub-range. This 2-pole device has a rated current of 20A and is designed for DIN rail mounting. It features a residual current sensitivity of 30mA / 0.03A and operates at a rated voltage (AC) of 240V phase-to-neutral. The device protects 1 pole and is characterized by a C tripping curve.
Quick Quote
Schneider Electric A9N18594 is an earth leakage add-on block designed for use with miniature circuit breakers, part of the Vigi C120 sub-range. This product features a rated current of 125A and is suitable for DIN rail mounting. It is a 3-pole device with dimensions of 95 mm in height, 73 mm in depth, and 171 mm in width. The A9N18594 operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 30mA or 0.03A. It is designed to protect 3 poles.
Quick Quote
Schneider Electric A9N18557 is an earth leakage add-on block designed for use with M.C.B., part of the Vigi C120 sub-range. It features a rated current of 125A and is suitable for DIN rail mounting. This product has 2 poles, with dimensions of 95 mm in height, 73 mm in depth, and 117 mm in width. It operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 1000mA or 1A. The A9N18557 ensures that both protected poles are effectively monitored for earth leakage.
Quick Quote
Schneider Electric A9R12440 is a Residual Current Circuit Breaker (RCCB) within the iID sub-range, designed for DIN rail mounting. This 4-pole device features a rated impulse voltage (Uimp) of 6 kV, a rated current of 40A, and a residual current sensitivity of 100mA / 0.1A. It has a mechanical durability of 20,000 operations at no load and an electrical durability of 15,000 operations with load. The RCCB has a net height of 91 mm, a net depth of 73.5 mm, and a net width of 72 mm. It is designed with a rated insulation voltage (Ui) of 500 V, a rated operating voltage (Ue) of 415 V, and a rated voltage (AC) phase-to-phase of 415 V, ensuring protection across all 4 poles.
Quick Quote
Schneider Electric A9D32613 is a Residual Current Circuit Breaker with Overload protection (RCBO) / Earth Leakage Circuit Breaker (ELCB) from the iDPN N Vigi sub-range. It features a rated current of 13A and is designed for DIN rail mounting. This 2 Pole device has dimensions of 85 mm in height, 73 mm in depth, and 36 mm in width. It operates at a rated voltage (AC) of 230V phase-to-neutral, with a residual current sensitivity of 30mA / 0.03A. The A9D32613 protects 1 Pole and offers both mechanical and electrical durability of 20,000 operations. It is characterized by a C tripping curve.
Quick Quote
Schneider Electric M9D14640 is a Residual Current Circuit Breaker with Overload protection (RCBO) / Earth Leakage Circuit Breaker (ELCB) from the N40 Vigi sub-range. This 2-pole device has a rated current of 40A and is designed for DIN rail mounting. It features a residual current sensitivity of 300mA / 0.3A and operates at a rated voltage (AC) of 240V phase-to-neutral. The device protects 1 pole and utilizes a C tripping curve.
Quick Quote
Schneider Electric A9R12240 is a Residual Current Circuit Breaker (RCCB) within the iID sub-range, designed for DIN rail mounting. This 2-pole RCCB features a rated impulse voltage (Uimp) of 6 kV, a rated current of 40A, and a residual current sensitivity of 100mA / 0.1A. It has a mechanical durability of 20,000 operations at no load and an electrical durability of 15,000 operations with load. The unit's dimensions are 91 mm in height, 73.5 mm in depth, and 36 mm in width. It operates with a rated insulation voltage (Ui) of 500 V, a rated operating voltage (Ue) of 240 V, and a rated voltage (AC) phase-to-neutral of 240 V, ensuring protection on both poles.
Quick Quote
Schneider Electric A9R41440 is a Residual Current Circuit Breaker (RCCB) within the iID sub-range, designed for DIN rail mounting. This 4-pole device features a rated impulse voltage (Uimp) of 6 kV, a rated current of 40A, and a residual current sensitivity of 30mA / 0.03A. It has a mechanical durability of 20,000 operations at no load and an electrical durability of 15,000 operations with load. The RCCB has a net height of 91 mm, a net depth of 73.5 mm, and a net width of 72 mm. It is designed for a rated insulation voltage (Ui) of 500 V and a rated operating voltage (Ue) of 415 V, with all four poles protected and a rated voltage (AC) phase-to-phase of 415 V.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
2CSF204201R3630 ABB 2CSF204201R3630 is a Residual Current Circuit Breaker (RCCB) designed with screw-clamp connections and a rated current of 63A. It features a Type A design and is suitable for DIN rail mounting. This RCCB has a net width for 4-poles (4P) and is specified with a control voltage for AC applications. The rated insulation voltage (Ui) is noted as 69 mm, which appears to be an error in the provided data, as voltage is not measured in millimeters. The supply voltage is designed for 400 V applications, and the device is capable of 10000 operations. It includes a number of Normally Closed (NC) circuits and is rated for 20000 operations for its analog outputs. The color specification is listed as 300mA, which seems to be a misplacement of information, as color typically does not have an electrical value. | ABB Control | Quick Quote | |||
2CSF202201R3400 ABB 2CSF202201R3400 is a Residual Current Circuit Breaker (RCCB) designed with screw-clamp connections and a rated current of 40A. It features a type A design and is suitable for DIN rail mounting. This RCCB has a rated insulation voltage (Ui) of 69 mm and operates with a control voltage that accommodates 400 V. It is equipped to handle a supply voltage for up to 10,000 operations and has a durability for analog outputs up to 20,000 operations. The device is structured with 2-poles (2P) and has a net width corresponding to the standard 85 mm communication protocol, while the rated impulse voltage (Uimp) stands at 35 mm. The color specification for this model is 300mA, indicating its operational capacity in terms of residual current detection. | ABB Control | Quick Quote | |||
M9D11620 Schneider Electric M9D11620 is a Residual Current Circuit Breaker with Overload protection (RCBO) / Earth Leakage Circuit Breaker (ELCB) from the N40 Vigi sub-range. This 2-pole device has a rated current of 20A and is designed for DIN rail mounting. It features a residual current sensitivity of 30mA / 0.03A and operates at a rated voltage (AC) of 240V phase-to-neutral. The device protects 1 pole and is characterized by a C tripping curve. | Schneider Electric | Quick Quote | |||
A9N18594 Schneider Electric A9N18594 is an earth leakage add-on block designed for use with miniature circuit breakers, part of the Vigi C120 sub-range. This product features a rated current of 125A and is suitable for DIN rail mounting. It is a 3-pole device with dimensions of 95 mm in height, 73 mm in depth, and 171 mm in width. The A9N18594 operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 30mA or 0.03A. It is designed to protect 3 poles. | Schneider Electric | Quick Quote | |||
A9N18557 Schneider Electric A9N18557 is an earth leakage add-on block designed for use with M.C.B., part of the Vigi C120 sub-range. It features a rated current of 125A and is suitable for DIN rail mounting. This product has 2 poles, with dimensions of 95 mm in height, 73 mm in depth, and 117 mm in width. It operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 1000mA or 1A. The A9N18557 ensures that both protected poles are effectively monitored for earth leakage. | Schneider Electric | Quick Quote | |||
A9R12440 Schneider Electric A9R12440 is a Residual Current Circuit Breaker (RCCB) within the iID sub-range, designed for DIN rail mounting. This 4-pole device features a rated impulse voltage (Uimp) of 6 kV, a rated current of 40A, and a residual current sensitivity of 100mA / 0.1A. It has a mechanical durability of 20,000 operations at no load and an electrical durability of 15,000 operations with load. The RCCB has a net height of 91 mm, a net depth of 73.5 mm, and a net width of 72 mm. It is designed with a rated insulation voltage (Ui) of 500 V, a rated operating voltage (Ue) of 415 V, and a rated voltage (AC) phase-to-phase of 415 V, ensuring protection across all 4 poles. | Schneider Electric | Quick Quote | |||
A9D32613 Schneider Electric A9D32613 is a Residual Current Circuit Breaker with Overload protection (RCBO) / Earth Leakage Circuit Breaker (ELCB) from the iDPN N Vigi sub-range. It features a rated current of 13A and is designed for DIN rail mounting. This 2 Pole device has dimensions of 85 mm in height, 73 mm in depth, and 36 mm in width. It operates at a rated voltage (AC) of 230V phase-to-neutral, with a residual current sensitivity of 30mA / 0.03A. The A9D32613 protects 1 Pole and offers both mechanical and electrical durability of 20,000 operations. It is characterized by a C tripping curve. | Schneider Electric | Quick Quote | |||
M9D14640 Schneider Electric M9D14640 is a Residual Current Circuit Breaker with Overload protection (RCBO) / Earth Leakage Circuit Breaker (ELCB) from the N40 Vigi sub-range. This 2-pole device has a rated current of 40A and is designed for DIN rail mounting. It features a residual current sensitivity of 300mA / 0.3A and operates at a rated voltage (AC) of 240V phase-to-neutral. The device protects 1 pole and utilizes a C tripping curve. | Schneider Electric | Quick Quote | |||
A9R12240 Schneider Electric A9R12240 is a Residual Current Circuit Breaker (RCCB) within the iID sub-range, designed for DIN rail mounting. This 2-pole RCCB features a rated impulse voltage (Uimp) of 6 kV, a rated current of 40A, and a residual current sensitivity of 100mA / 0.1A. It has a mechanical durability of 20,000 operations at no load and an electrical durability of 15,000 operations with load. The unit's dimensions are 91 mm in height, 73.5 mm in depth, and 36 mm in width. It operates with a rated insulation voltage (Ui) of 500 V, a rated operating voltage (Ue) of 240 V, and a rated voltage (AC) phase-to-neutral of 240 V, ensuring protection on both poles. | Schneider Electric | Quick Quote | |||
A9R41440 Schneider Electric A9R41440 is a Residual Current Circuit Breaker (RCCB) within the iID sub-range, designed for DIN rail mounting. This 4-pole device features a rated impulse voltage (Uimp) of 6 kV, a rated current of 40A, and a residual current sensitivity of 30mA / 0.03A. It has a mechanical durability of 20,000 operations at no load and an electrical durability of 15,000 operations with load. The RCCB has a net height of 91 mm, a net depth of 73.5 mm, and a net width of 72 mm. It is designed for a rated insulation voltage (Ui) of 500 V and a rated operating voltage (Ue) of 415 V, with all four poles protected and a rated voltage (AC) phase-to-phase of 415 V. | Schneider Electric | Quick Quote |