ABB GJH1213003R0225 is a magnetic mini contactor from the KC6 contactors sub-range. It features flat pin / Faston connections and is designed with 4 poles (2NO+2NC). The rated current varies with voltage: 4A for 24-240Vac (AC-15), 3A for 440Vac (AC-15), 2A for 500Vac (AC-15), and 5A for 600Vac under UL/CSA general use rating. The rated insulation voltage is 690 V according to IEC/VDE and 600 V according to UL/CSA. This contactor is designed for mounting on a plate, with dimensions of 57.5 mm in height, 52.5 mm in width, and 46.5 mm in depth. It operates with a control voltage of 220Vdc-240Vdc and consumes 3.5W both in inrush and holding states for the coil. The rated operating voltage (Ue) is 690 V, and it has no Normally Open (NO) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and it also features no Normally Closed (NC) auxiliary contacts. Its operating rate is 600 cycles/hour under DC-13 conditions.
Quick Quote
ABB GJH1213003R0314 is a magnetic mini contactor from the KC6 contactors sub-range. It features flat pin / Faston connections and is designed with 4 poles (3NO+1NC), supporting a rated current of 4A at 24-240Vac (AC-15), 3A at 440Vac (AC-15), 2A at 500Vac (AC-15), and 5A at 600Vac under UL/CSA general use rating. The rated insulation voltage is 690 V according to IEC/VDE and 600 V according to UL/CSA. This contactor is suitable for mounting on a plate, with dimensions of 57.5 mm in height, 52.5 mm in width, and 46.5 mm in depth. It operates with a control voltage of 110Vdc-125Vdc and consumes 3.5W during both inrush and holding phases of the coil. The rated operating voltage (Ue) is 690 V, and it has an impulse withstand voltage (Uimp) of 6 kV. Despite having 4 poles, it does not include any Normally Open (NO) or Normally Closed (NC) auxiliary contacts. It is capable of operating at a rate of 600 cycles/hour under DC-13 conditions.
Quick Quote
ABB GJH1213003R0224 is a magnetic mini contactor from the KC6 contactors sub-range. This 4-pole (4P; 2NO+2NC) contactor is designed for flat pin / Faston connections and supports a rated current of 4A at 24-240Vac (AC-15), 3A at 440Vac (AC-15), 2A at 500Vac (AC-15), and 5A at 600Vac under UL/CSA general use rating. It features a rated insulation voltage of 690 V according to IEC/VDE and 600 V according to UL/CSA. The contactor is suitable for mounting on a plate, with dimensions of 57.5 mm in height, 52.5 mm in width, and 46.5 mm in depth. It operates with a control voltage of 110Vdc-125Vdc and consumes 3.5W during both inrush and holding phases of the coil. The rated operating voltage (Ue) is 690 V, and it has an impulse withstand voltage (Uimp) of 6 kV. This model does not include normally open (NO) or normally closed (NC) auxiliary contacts and is capable of operating at a rate of 600 cycles/hour under DC-13 conditions.
Quick Quote
ABB GJH1213001R0317 is a magnetic mini contactor from the KC6 contactors sub-range, designed with screw-clamp connections and featuring 4-poles (3NO+1NC). It has a rated current of 4A for 24-240Vac (AC-15), 3A for 440Vac (AC-15), 2A for 500Vac (AC-15), and a 5A general use rating for 600Vac (UL/CSA). The rated insulation voltage is 690 V (IEC/VDE) and 600 V (UL/CSA), with a mounting mode on the plate. The dimensions include a net height of 57.5 mm, a net width of 52.5 mm, and a net depth of 46.5 mm. It operates with a control voltage of 12Vdc and a current consumption of 3.5W for both inrush and holding (coil). The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 6 kV. It does not have Normally Open (NO) auxiliary contacts, features 0 NC auxiliary contacts, and has an operating rate of 600 cycles/hour (DC-13).
Quick Quote
ABB GJH1213001R0315 is a magnetic mini contactor from the KC6 contactors sub-range, designed with screw-clamp connections and featuring 4 poles (3NO+1NC). It has a rated current of 4A for 24-240Vac (AC-15), 3A for 440Vac (AC-15), 2A for 500Vac (AC-15), and a 5A general use rating for 600Vac according to UL/CSA standards. The rated insulation voltage is 690 V according to IEC/VDE and 600 V according to UL/CSA, with a mounting mode on the plate. The dimensions include a net height of 57.5 mm, a net width of 52.5 mm, and a net depth of 46.5 mm. It operates with a control voltage of 220Vdc-240Vdc, consuming 3.5W both in inrush and holding states for the coil. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 6 kV. It does not have Normally Open (NO) auxiliary contacts, features 0 Normally Closed (NC) auxiliary contacts, and supports an operating rate of 600 cycles/hour under DC-13 conditions.
Quick Quote
ABB GJH1213001R0221 is a magnetic mini contactor from the KC6 contactors sub-range, designed with screw-clamp connections and featuring 4 poles (2NO+2NC). It has a rated current of 4A for 24-240Vac (AC-15), 3A for 440Vac (AC-15), 2A for 500Vac (AC-15), and a 5A general use rating for 600Vac (UL/CSA). The rated insulation voltage is 690 V according to IEC/VDE standards and 600 V according to UL/CSA standards. This contactor is designed for mounting on a plate, with dimensions of 57.5 mm in height, 52.5 mm in width, and 46.5 mm in depth. It operates with a control voltage of 24Vdc and consumes 3.5W during both inrush and holding phases of the coil. The rated operating voltage (Ue) is 690 V, and it has no Normally Open (NO) or Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and it supports an operating rate of 600 cycles/hour (DC-13).
Quick Quote
ABB GJH1213001R0224 is a magnetic mini contactor from the KC6 contactors sub-range. It features screw-clamp connections and is designed with 4 poles (2NO+2NC). The rated current varies by voltage: 4A for 24-240Vac (AC-15), 3A for 440Vac (AC-15), 2A for 500Vac (AC-15), and 5A for 600Vac under UL/CSA general use rating. The rated insulation voltage is 690 V according to IEC/VDE standards and 600 V according to UL/CSA standards. This contactor is designed for mounting on a plate, with dimensions of 57.5 mm in height, 52.5 mm in width, and 46.5 mm in depth. It operates with a control voltage of 110Vdc-125Vdc and consumes 3.5W both in inrush and holding states for the coil. The rated operating voltage (Ue) is 690 V, and it has no normally open (NO) or normally closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and it supports an operating rate of 600 cycles/hour under DC-13 conditions.
Quick Quote
ABB GJH1211009R8400 is a magnetic mini contactor from the K6 contactors sub-range designed for soldering P.C.B. pin connections. It features 4 poles (4NO) and offers a variety of rated currents: 4A for 24-240Vac (AC-15), 3A for 440Vac (AC-15), 2A for 500Vac (AC-15), and 5A for 600Vac under UL/CSA general use rating. The rated insulation voltage is 690 V according to IEC/VDE and 600 V according to UL/CSA, with a mounting mode on P.C.B. The dimensions include a net height of 45.5 mm, width of 47.5 mm, and depth of 51.5 mm. It consumes 3.5VA for both inrush and holding (coil) with a control voltage (AC) of 220Vac-240Vac (230Vac) across a frequency range of 40Hz-450Hz. The rated operating voltage (Ue) is 690 V, and it has no normally open (NO) or normally closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and it can operate at a rate of 600 cycles/hour (DC-13).
Quick Quote
ABB GJH1211009R0401 is a magnetic mini contactor from the K6 contactors sub-range, designed for soldering P.C.B. pin connections. This 4-pole (4P; 4NO) contactor supports a rated current of 4A at 24-240Vac (AC-15), 3A at 440Vac (AC-15), 2A at 500Vac (AC-15), and 5A at 600Vac (UL/CSA general use rating). It features a rated insulation voltage of 690 V (IEC/VDE) and 600 V (UL/CSA), with a mounting mode on P.C.B. The dimensions include a net height of 45.5 mm, width of 47.5 mm, and depth of 51.5 mm. The current consumption is 3.5VA for both inrush and holding (coil), with a control voltage (AC) of 24Vac (40Hz-450Hz). The rated operating voltage (Ue) is 690 V, and it has no normally open (NO) or normally closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and it operates at a rate of 600 cycles/hour (DC-13).
Quick Quote
ABB GJH1211003R8400 is a magnetic mini contactor from the K6 contactors sub-range, designed with flat pin / Faston connections and equipped with 4 poles (4P; 4NO). It has a rated current of 4A for 24-240Vac (AC-15), 3A for 440Vac (AC-15), 2A for 500Vac (AC-15), and a 5A UL/CSA general use rating for 600Vac. The rated insulation voltage is 690 V according to IEC/VDE and 600 V according to UL/CSA, with a mounting mode on the plate. The dimensions include a net height of 57.5 mm, a net width of 52.5 mm, and a net depth of 46.5 mm. It consumes 3.5VA during both inrush and holding phases of the coil, operates with a control voltage of 220Vac-240Vac (230Vac) across a frequency range of 40Hz-450Hz, and has a rated operating voltage (Ue) of 690 V. This contactor does not include normally open (NO) or normally closed (NC) auxiliary contacts, has a rated impulse voltage (Uimp) of 6 kV, and supports an operating rate of 600 cycles/hour under DC-13 conditions.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
GJH1213003R0225 ABB GJH1213003R0225 is a magnetic mini contactor from the KC6 contactors sub-range. It features flat pin / Faston connections and is designed with 4 poles (2NO+2NC). The rated current varies with voltage: 4A for 24-240Vac (AC-15), 3A for 440Vac (AC-15), 2A for 500Vac (AC-15), and 5A for 600Vac under UL/CSA general use rating. The rated insulation voltage is 690 V according to IEC/VDE and 600 V according to UL/CSA. This contactor is designed for mounting on a plate, with dimensions of 57.5 mm in height, 52.5 mm in width, and 46.5 mm in depth. It operates with a control voltage of 220Vdc-240Vdc and consumes 3.5W both in inrush and holding states for the coil. The rated operating voltage (Ue) is 690 V, and it has no Normally Open (NO) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and it also features no Normally Closed (NC) auxiliary contacts. Its operating rate is 600 cycles/hour under DC-13 conditions. | ABB Control | Quick Quote | |||
GJH1213003R0314 ABB GJH1213003R0314 is a magnetic mini contactor from the KC6 contactors sub-range. It features flat pin / Faston connections and is designed with 4 poles (3NO+1NC), supporting a rated current of 4A at 24-240Vac (AC-15), 3A at 440Vac (AC-15), 2A at 500Vac (AC-15), and 5A at 600Vac under UL/CSA general use rating. The rated insulation voltage is 690 V according to IEC/VDE and 600 V according to UL/CSA. This contactor is suitable for mounting on a plate, with dimensions of 57.5 mm in height, 52.5 mm in width, and 46.5 mm in depth. It operates with a control voltage of 110Vdc-125Vdc and consumes 3.5W during both inrush and holding phases of the coil. The rated operating voltage (Ue) is 690 V, and it has an impulse withstand voltage (Uimp) of 6 kV. Despite having 4 poles, it does not include any Normally Open (NO) or Normally Closed (NC) auxiliary contacts. It is capable of operating at a rate of 600 cycles/hour under DC-13 conditions. | ABB Control | Quick Quote | |||
GJH1213003R0224 ABB GJH1213003R0224 is a magnetic mini contactor from the KC6 contactors sub-range. This 4-pole (4P; 2NO+2NC) contactor is designed for flat pin / Faston connections and supports a rated current of 4A at 24-240Vac (AC-15), 3A at 440Vac (AC-15), 2A at 500Vac (AC-15), and 5A at 600Vac under UL/CSA general use rating. It features a rated insulation voltage of 690 V according to IEC/VDE and 600 V according to UL/CSA. The contactor is suitable for mounting on a plate, with dimensions of 57.5 mm in height, 52.5 mm in width, and 46.5 mm in depth. It operates with a control voltage of 110Vdc-125Vdc and consumes 3.5W during both inrush and holding phases of the coil. The rated operating voltage (Ue) is 690 V, and it has an impulse withstand voltage (Uimp) of 6 kV. This model does not include normally open (NO) or normally closed (NC) auxiliary contacts and is capable of operating at a rate of 600 cycles/hour under DC-13 conditions. | ABB Control | Quick Quote | |||
GJH1213001R0317 ABB GJH1213001R0317 is a magnetic mini contactor from the KC6 contactors sub-range, designed with screw-clamp connections and featuring 4-poles (3NO+1NC). It has a rated current of 4A for 24-240Vac (AC-15), 3A for 440Vac (AC-15), 2A for 500Vac (AC-15), and a 5A general use rating for 600Vac (UL/CSA). The rated insulation voltage is 690 V (IEC/VDE) and 600 V (UL/CSA), with a mounting mode on the plate. The dimensions include a net height of 57.5 mm, a net width of 52.5 mm, and a net depth of 46.5 mm. It operates with a control voltage of 12Vdc and a current consumption of 3.5W for both inrush and holding (coil). The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 6 kV. It does not have Normally Open (NO) auxiliary contacts, features 0 NC auxiliary contacts, and has an operating rate of 600 cycles/hour (DC-13). | ABB Control | Quick Quote | |||
GJH1213001R0315 ABB GJH1213001R0315 is a magnetic mini contactor from the KC6 contactors sub-range, designed with screw-clamp connections and featuring 4 poles (3NO+1NC). It has a rated current of 4A for 24-240Vac (AC-15), 3A for 440Vac (AC-15), 2A for 500Vac (AC-15), and a 5A general use rating for 600Vac according to UL/CSA standards. The rated insulation voltage is 690 V according to IEC/VDE and 600 V according to UL/CSA, with a mounting mode on the plate. The dimensions include a net height of 57.5 mm, a net width of 52.5 mm, and a net depth of 46.5 mm. It operates with a control voltage of 220Vdc-240Vdc, consuming 3.5W both in inrush and holding states for the coil. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 6 kV. It does not have Normally Open (NO) auxiliary contacts, features 0 Normally Closed (NC) auxiliary contacts, and supports an operating rate of 600 cycles/hour under DC-13 conditions. | ABB Control | Quick Quote | |||
GJH1213001R0221 ABB GJH1213001R0221 is a magnetic mini contactor from the KC6 contactors sub-range, designed with screw-clamp connections and featuring 4 poles (2NO+2NC). It has a rated current of 4A for 24-240Vac (AC-15), 3A for 440Vac (AC-15), 2A for 500Vac (AC-15), and a 5A general use rating for 600Vac (UL/CSA). The rated insulation voltage is 690 V according to IEC/VDE standards and 600 V according to UL/CSA standards. This contactor is designed for mounting on a plate, with dimensions of 57.5 mm in height, 52.5 mm in width, and 46.5 mm in depth. It operates with a control voltage of 24Vdc and consumes 3.5W during both inrush and holding phases of the coil. The rated operating voltage (Ue) is 690 V, and it has no Normally Open (NO) or Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and it supports an operating rate of 600 cycles/hour (DC-13). | ABB Control | Quick Quote | |||
GJH1213001R0224 ABB GJH1213001R0224 is a magnetic mini contactor from the KC6 contactors sub-range. It features screw-clamp connections and is designed with 4 poles (2NO+2NC). The rated current varies by voltage: 4A for 24-240Vac (AC-15), 3A for 440Vac (AC-15), 2A for 500Vac (AC-15), and 5A for 600Vac under UL/CSA general use rating. The rated insulation voltage is 690 V according to IEC/VDE standards and 600 V according to UL/CSA standards. This contactor is designed for mounting on a plate, with dimensions of 57.5 mm in height, 52.5 mm in width, and 46.5 mm in depth. It operates with a control voltage of 110Vdc-125Vdc and consumes 3.5W both in inrush and holding states for the coil. The rated operating voltage (Ue) is 690 V, and it has no normally open (NO) or normally closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and it supports an operating rate of 600 cycles/hour under DC-13 conditions. | ABB Control | Quick Quote | |||
GJH1211009R8400 ABB GJH1211009R8400 is a magnetic mini contactor from the K6 contactors sub-range designed for soldering P.C.B. pin connections. It features 4 poles (4NO) and offers a variety of rated currents: 4A for 24-240Vac (AC-15), 3A for 440Vac (AC-15), 2A for 500Vac (AC-15), and 5A for 600Vac under UL/CSA general use rating. The rated insulation voltage is 690 V according to IEC/VDE and 600 V according to UL/CSA, with a mounting mode on P.C.B. The dimensions include a net height of 45.5 mm, width of 47.5 mm, and depth of 51.5 mm. It consumes 3.5VA for both inrush and holding (coil) with a control voltage (AC) of 220Vac-240Vac (230Vac) across a frequency range of 40Hz-450Hz. The rated operating voltage (Ue) is 690 V, and it has no normally open (NO) or normally closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and it can operate at a rate of 600 cycles/hour (DC-13). | ABB Control | Quick Quote | |||
GJH1211009R0401 ABB GJH1211009R0401 is a magnetic mini contactor from the K6 contactors sub-range, designed for soldering P.C.B. pin connections. This 4-pole (4P; 4NO) contactor supports a rated current of 4A at 24-240Vac (AC-15), 3A at 440Vac (AC-15), 2A at 500Vac (AC-15), and 5A at 600Vac (UL/CSA general use rating). It features a rated insulation voltage of 690 V (IEC/VDE) and 600 V (UL/CSA), with a mounting mode on P.C.B. The dimensions include a net height of 45.5 mm, width of 47.5 mm, and depth of 51.5 mm. The current consumption is 3.5VA for both inrush and holding (coil), with a control voltage (AC) of 24Vac (40Hz-450Hz). The rated operating voltage (Ue) is 690 V, and it has no normally open (NO) or normally closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and it operates at a rate of 600 cycles/hour (DC-13). | ABB Control | Quick Quote | |||
GJH1211003R8400 ABB GJH1211003R8400 is a magnetic mini contactor from the K6 contactors sub-range, designed with flat pin / Faston connections and equipped with 4 poles (4P; 4NO). It has a rated current of 4A for 24-240Vac (AC-15), 3A for 440Vac (AC-15), 2A for 500Vac (AC-15), and a 5A UL/CSA general use rating for 600Vac. The rated insulation voltage is 690 V according to IEC/VDE and 600 V according to UL/CSA, with a mounting mode on the plate. The dimensions include a net height of 57.5 mm, a net width of 52.5 mm, and a net depth of 46.5 mm. It consumes 3.5VA during both inrush and holding phases of the coil, operates with a control voltage of 220Vac-240Vac (230Vac) across a frequency range of 40Hz-450Hz, and has a rated operating voltage (Ue) of 690 V. This contactor does not include normally open (NO) or normally closed (NC) auxiliary contacts, has a rated impulse voltage (Uimp) of 6 kV, and supports an operating rate of 600 cycles/hour under DC-13 conditions. | ABB Control | Quick Quote |