Manufacturer
Compressed Air Preparation Units
Festo

Compressed Air Preparation Units - Festo

Also referred to as an FRL unit (Filter, Regulator, Lubricator), an air preparation unit is utilized to treat compressed air. It accomplishes this by eliminating impurities, managing pressure, and adding specific quantities of oil for lubrication.

Festo
Festo

Found 3,056 products

185712
Festo

service unit LFR-1/4-D-MIDI-KA-A consisting of filter regulator and distributor module, with mounting brackets. With automatic condensate drain. Size: Midi, Series: D, Actuator lock: Rotary knob with lock, Assembly position: Vertical +/- 5°, Grade of filt

Quick Quote

552935
Festo

pressure booster DPA-63-16-CRVZS20 combination of pressure booster and air reservoir in stainless steel design Piston diameter: 63 mm, Volume: 20 l, Assembly position: Downward condensate drain, Design structure: (* Twin-piston pressure booster, * with ai

Quick Quote

553042
Festo

fine filter MS9-LFM-1-BUM-HF 1 µm filter, metal bowl guard, high flow rate, manual condensate drain, flow direction from left to right. Series: MS, Size: 9, Design structure: Fibre filter, Grade of filtration: 1 µm, Condensate drain: manual rotary

Quick Quote

553092
Festo

fine filter MS9-LFM-N3/4-BUV 1 µm filter, metal bowl guard, fully automatic condensate drain, flow direction from left to right. Series: MS, Size: 9, Design structure: Fibre filter, Grade of filtration: 1 µm, Condensate drain: (* fully automatic, * manual

Quick Quote

186060
Festo

service unit FRC-1/2-D-MAXI-KE-A consisting of filter regulator, lubricator, on/off valve with solenoid coil 24 V DC without socket, and pressure build-up valve with mounting brackets. With automatic condensate drain and metal bowl guard. Size: Maxi, Seri

Quick Quote

536527
Festo

electrical pressure regulator MS6N-LRE-1/4-D6-PI-Z Indirectly controlled regulators, working pressure up to 7 bar. Size: 6, Series: MS, Assembly position: (* Any, * Preferably vertical), Design structure: Electrically adjustable pressure regulator, Short

Quick Quote

535690
Festo

filter MS4N-LF-1/4-EUV 40 µm filter, metal bowl guard, fully automatic condensate drain, flow direction from left to right. Size: 4, Series: MS, Assembly position: Vertical +/- 5°, Grade of filtration: 40 µm, Condensate drain: fully automatic

Quick Quote

550509
Festo

service unit combination MSB6N-1/2:J2D7A1-WP Comprising filter regulator, electrical on-off valve, pneumatic soft-start valve, wall mounting plate. Maximum output pressure 9 bar, 40 µm filter, with pressure gauge, lockable regulator head, plastic bowl wit

Quick Quote

185753
Festo

service unit LFR-3/4-D-MAXI-KD consisting of filter regulator, on/off valve with solenoid coil 24 V DC, without socket,, and pressure build-up valve, with mounting brackets. With manual condensate drain. Size: Maxi, Series: D, Actuator lock: Rotary knob w

Quick Quote

185735
Festo

service unit LFR-1/4-D-MIDI-KC consisting of manual on/off valve and filter regulator, with mounting brackets. With manual condensate drain. Size: Midi, Series: D, Actuator lock: Rotary knob with lock, Assembly position: Vertical +/- 5°, Grade of filtrati

Quick Quote

ItemManufacturerPriceStockDelivery
185712

185712

service unit LFR-1/4-D-MIDI-KA-A consisting of filter regulator and distributor module, with mounting brackets. With automatic condensate drain. Size: Midi, Series: D, Actuator lock: Rotary knob with lock, Assembly position: Vertical +/- 5°, Grade of filt

Festo

Quick Quote

552935

552935

pressure booster DPA-63-16-CRVZS20 combination of pressure booster and air reservoir in stainless steel design Piston diameter: 63 mm, Volume: 20 l, Assembly position: Downward condensate drain, Design structure: (* Twin-piston pressure booster, * with ai

Festo

Quick Quote

553042

553042

fine filter MS9-LFM-1-BUM-HF 1 µm filter, metal bowl guard, high flow rate, manual condensate drain, flow direction from left to right. Series: MS, Size: 9, Design structure: Fibre filter, Grade of filtration: 1 µm, Condensate drain: manual rotary

Festo

Quick Quote

553092

553092

fine filter MS9-LFM-N3/4-BUV 1 µm filter, metal bowl guard, fully automatic condensate drain, flow direction from left to right. Series: MS, Size: 9, Design structure: Fibre filter, Grade of filtration: 1 µm, Condensate drain: (* fully automatic, * manual

Festo

Quick Quote

186060

186060

service unit FRC-1/2-D-MAXI-KE-A consisting of filter regulator, lubricator, on/off valve with solenoid coil 24 V DC without socket, and pressure build-up valve with mounting brackets. With automatic condensate drain and metal bowl guard. Size: Maxi, Seri

Festo

Quick Quote

536527

536527

electrical pressure regulator MS6N-LRE-1/4-D6-PI-Z Indirectly controlled regulators, working pressure up to 7 bar. Size: 6, Series: MS, Assembly position: (* Any, * Preferably vertical), Design structure: Electrically adjustable pressure regulator, Short

Festo

Quick Quote

535690

535690

filter MS4N-LF-1/4-EUV 40 µm filter, metal bowl guard, fully automatic condensate drain, flow direction from left to right. Size: 4, Series: MS, Assembly position: Vertical +/- 5°, Grade of filtration: 40 µm, Condensate drain: fully automatic

Festo

Quick Quote

550509

550509

service unit combination MSB6N-1/2:J2D7A1-WP Comprising filter regulator, electrical on-off valve, pneumatic soft-start valve, wall mounting plate. Maximum output pressure 9 bar, 40 µm filter, with pressure gauge, lockable regulator head, plastic bowl wit

Festo

Quick Quote

185753

185753

service unit LFR-3/4-D-MAXI-KD consisting of filter regulator, on/off valve with solenoid coil 24 V DC, without socket,, and pressure build-up valve, with mounting brackets. With manual condensate drain. Size: Maxi, Series: D, Actuator lock: Rotary knob w

Festo

Quick Quote

185735

185735

service unit LFR-1/4-D-MIDI-KC consisting of manual on/off valve and filter regulator, with mounting brackets. With manual condensate drain. Size: Midi, Series: D, Actuator lock: Rotary knob with lock, Assembly position: Vertical +/- 5°, Grade of filtrati

Festo

Quick Quote

Compressed Air Preparation Units

General Guide & Overview

Compressed air is a widely used form of energy in various industries, powering pneumatic systems and equipment. However, the air leaving the compressor is often not suitable for direct use due to impurities and incorrect pressure levels. That's where air preparation units, also known as FRL units (Filter, Regulator, Lubricator), play a crucial role.

Air preparation units are designed to condition the compressed air, ensuring optimal performance and efficiency. The FRL unit consists of three separate units that carry out different phases of conditioning: filtration, regulation, and lubrication.

Filtration is the first step, where contaminants such as dust, water, and oil are removed from the compressed air. This ensures that downstream equipment remains protected and operates at its best. Regulation is the second phase, controlling the pressure of the compressed air in the system to match the requirements of the application. Lastly, lubrication introduces controlled amounts of oil into the flow of compressed air, reducing friction and increasing the lifespan of air-driven equipment.

Proper selection of the filter size, pressure rating, port size, and lubricator type is essential to meet the specific requirements of each application. By investing in high-quality compressed air preparation units, you can ensure the longevity of your pneumatic equipment and optimize its performance.

So, whether you are in manufacturing, automotive, or any other industry that relies on compressed air, understanding the importance of air preparation units is vital for efficient and reliable operation.

Importance of Air Preparation in Pneumatic Systems

Air preparation plays a vital role in pneumatic systems, ensuring the cleanliness, pressure, and lubrication of compressed air. In order to maintain optimal performance and reliability, it is crucial to address the presence of contaminants such as particles, water, and oil that can impair the operation of pneumatic components. Proper filtration is necessary to remove dirt, dust, and other particles from the compressed air and minimize the risk of damage to downstream equipment.

Moisture and oil, which can negatively impact the performance of pneumatic systems, are effectively eliminated through the use of coalescing filters. The level of air purity required will vary depending on the specific application, and different industry segments may have additional requirements to ensure the proper functioning of their equipment. Therefore, it is essential to select and implement the appropriate air preparation measures.

In addition to addressing contaminants, the flow rate of compressed air must be adequate to achieve the desired cylinder piston travel speeds. Furthermore, the operating pressure of the system needs to be carefully matched to the requirements of the application for optimal performance. By paying attention to these factors and implementing proper air preparation techniques, businesses can improve the process reliability, machine availability, and service life of their pneumatic components.

Tips for Designing and Specifying Air Preparation Systems

When designing or specifying air preparation subsystems, engineers need to consider several key factors to ensure optimal performance and minimize maintenance costs. One crucial aspect is properly matching the port sizes and operating pressure ranges of pneumatic components. This ensures efficient operation and prevents issues such as pressure drops or excessive pressure that can lead to equipment damage or downtime.

Another important consideration is the inclusion of disconnect components, such as manual shut-off relief valves and isolation/lockout valves. These components provide a means to isolate downstream equipment from the compressed air source, allowing for safe maintenance procedures and preventing inadvertent re-energization. This not only enhances safety but also reduces the risk of equipment breakdown and associated maintenance costs.

Air filtration is a critical aspect of air preparation systems, as it eliminates contaminants that could affect the performance and lifespan of pneumatic equipment. Various passive filters, such as centrifugal and coalescing filters, effectively remove particles, water, and oil from the compressed air, ensuring clean and reliable operation. Additionally, implementing appropriate drain systems, such as manual, semi-automatic, or automatic drains, helps to remove accumulated moisture from the filter bowl, further enhancing the efficiency and longevity of the system.

Finally, maintaining proper downstream air pressure is of utmost importance. This can be achieved through the installation of air pressure regulators. These regulators ensure that the compressed air delivered to the equipment operates at the correct pressure, preventing potential damage or inefficiencies caused by excessive or insufficient pressure. By following these tips and incorporating the right components, engineers can design and specify air preparation systems that optimize the performance and longevity of pneumatic equipment, ultimately reducing maintenance costs and downtime.

FAQ

An air preparation unit, also known as an FRL unit (Filter, Regulator, Lubricator), is used to condition compressed air by removing contaminants, regulating pressure, and introducing controlled amounts of oil for lubrication.

Air preparation is essential in pneumatic systems to ensure the correct air cleanliness, pressure, and lubrication. Contaminants can impair the operation of components and reduce system reliability.

Filtration in an air preparation unit removes contaminants such as dust, water, and oil from the compressed air, ensuring cleaner air for downstream equipment.

Regulation in an air preparation unit controls the pressure of the compressed air in the system, allowing for precise pressure adjustments based on the requirements of the application.

Lubrication in an air preparation unit introduces controlled amounts of oil into the compressed air flow, reducing friction and increasing the lifespan of air-driven equipment.

When designing or specifying air preparation subsystems, consider proper port sizes and operating pressure ranges, disconnect components for isolation and lockout, air filtration for removing contaminants, drain systems for moisture removal, and air pressure regulators for maintaining proper downstream pressure.