All categories
Automation components
All categories
Automation components
Lenze 841-005 is a brake unit designed for dynamic braking with an integrated braking resistor unit. It operates on a 3-phase (3P / 3AC) power supply, with a voltage range of 240-590Vac. The unit features residual current sensitivity and has dimensions of H200mm x W102mm x D38mm.
Quick Quote
Lenze ESV112N01SMC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65. The dimensions are H279mm x W160mm x D182mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs for START/STOP and additional functions at terminals 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). It is designed with a built-in disconnect switch, for indoor use only, and utilizes natural convection cooling (fan-less). The supply voltage is 120Vac / 240Vac with a network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 6A for both 120Vac and 240Vac, supporting a single-phase / 1P network. The rated active power is 1.1kW, and the rated power is 1-1/2HP for both 120Vac and 240Vac.
Quick Quote
Lenze ESV113N02TXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H318mm x W176mm x D205mm. It also includes 1 digital output (NPN; 24Vdc / 50mA) at Terminal 14, 2 analog inputs (0-10Vdc at terminal 5 and 4-20mA at terminal 25), and 5 digital inputs with various terminals for START/STOP and additional controls. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size J1, it has a supply voltage of 240Vac, network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 42A at 240Vac, for a 3-phase network, with a rated active power of 11kW and rated power of 15HP at 240Vac.
Quick Quote
Lenze ESV222N04TFC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65. It also includes 1 digital output (NPN; 24Vdc / 50mA) at Terminal 14, alongside 1 analog input (0-10Vdc) at terminal 5 and 1 analog input (4-20mA) at terminal 25. The digital inputs consist of 1 x digital input (PNP/NPN logic) at terminal 1 for START/STOP functions, and 4 additional digital inputs at terminals 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). It is designed with a built-in EMC filter, is intended for indoor use only, and utilizes natural convection cooling without a fan. The supply voltage is rated at 400Vac / 480Vac, with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). This model does not include a communication interface. The rated current is 5.5A at 400Vac and 4.8A at 480Vac, for a 3-phase network. It has a rated active power of 2.2kW and a rated power of 3HP for both 400-480Vac.
Quick Quote
Lenze ESV152N04TXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H191mm x W99mm x D138mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs (PNP/NPN logic) at terminals 1 START/STOP, 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size G2, it supports a supply voltage of 400Vac / 480Vac, network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 4A at 400Vac and 3.5A at 480Vac, for a 3-phase network. Rated active power is 1.5kW and rated power is 2HP for 400-480Vac.
Quick Quote
Lenze ESV222N02YXC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40 °C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65. The dimensions are H203mm x W181mm x D172mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs (PNP/NPN logic) at terminals 1 START/STOP, 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only, it has a frame size S1 with natural convection cooling (fan-less). The supply voltage is 240Vac, with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). It does not include a communication interface. The rated current is 9.6A at 240Vac, supporting both single-phase and 3-phase networks. The rated active power is 2.2kW (240Vac), equivalent to 3HP (240Vac).
Quick Quote
Lenze ESV223N04TXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H318mm x W176mm x D205mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs including 1 x digital input (PNP/NPN logic) at terminal 1 for START/STOP, and 1 x digital input each at terminals 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size J1, it supports a supply voltage of 400Vac / 480Vac, network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 46A (400Vac) and 40A (480Vac), for a 3-phase network. It offers a rated active power of 22kW and rated power of 30HP for 400-480Vac.
Quick Quote
Lenze ESV371N04TLC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, alongside 1 x analog input (0-10Vdc) at terminal 5 and 1 x analog input (4-20mA) at terminal 25. The digital inputs consist of 1 x digital input (PNP/NPN logic) at terminal 1 for START/STOP functions, and 1 x digital input each at terminals 13A, 13B, 13C, and 13D. Protection functions include earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Its design incorporates a built-in EMC filter, a built-in disconnect switch, and utilizes natural convection cooling (fan-less) suitable for indoor use only. The supply voltage is rated at 400Vac / 480Vac with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). It does not have a communication interface. The rated current is 1.3A at 400Vac and 1.1A at 480Vac, for a 3-phase network. The rated active power is 0.37kW, and the rated power is 1/2HP for both 400-480Vac.
Quick Quote
Lenze ESV552N04TXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H250mm x W130mm x D160mm. It includes 1 digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 analog input (0-10Vdc) at terminal 5, 1 analog input (4-20mA) at terminal 25, and multiple digital inputs (PNP/NPN logic) at terminals 1 START/STOP, 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size H1, it supports a supply voltage of 400Vac / 480Vac, network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 12.6A at 400Vac and 11A at 480Vac, for a 3-phase network. It has a rated active power of 5.5kW and rated power of 7-1/2HP for 400-480Vac.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
13303309 Asynchronous Servo Motor / NCNR | Lenze | $13,552.63 | Quick Quote | ||
841-005 Lenze 841-005 is a brake unit designed for dynamic braking with an integrated braking resistor unit. It operates on a 3-phase (3P / 3AC) power supply, with a voltage range of 240-590Vac. The unit features residual current sensitivity and has dimensions of H200mm x W102mm x D38mm. | Lenze | $152.11 | Quick Quote | ||
ESV112N01SMC Lenze ESV112N01SMC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65. The dimensions are H279mm x W160mm x D182mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs for START/STOP and additional functions at terminals 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). It is designed with a built-in disconnect switch, for indoor use only, and utilizes natural convection cooling (fan-less). The supply voltage is 120Vac / 240Vac with a network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 6A for both 120Vac and 240Vac, supporting a single-phase / 1P network. The rated active power is 1.1kW, and the rated power is 1-1/2HP for both 120Vac and 240Vac. | Lenze | $1,054.29 | Quick Quote | ||
ESV113N02TXB Lenze ESV113N02TXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H318mm x W176mm x D205mm. It also includes 1 digital output (NPN; 24Vdc / 50mA) at Terminal 14, 2 analog inputs (0-10Vdc at terminal 5 and 4-20mA at terminal 25), and 5 digital inputs with various terminals for START/STOP and additional controls. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size J1, it has a supply voltage of 240Vac, network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 42A at 240Vac, for a 3-phase network, with a rated active power of 11kW and rated power of 15HP at 240Vac. | Lenze | $1,917.71 | Quick Quote | ||
ESV222N04TFC Lenze ESV222N04TFC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65. It also includes 1 digital output (NPN; 24Vdc / 50mA) at Terminal 14, alongside 1 analog input (0-10Vdc) at terminal 5 and 1 analog input (4-20mA) at terminal 25. The digital inputs consist of 1 x digital input (PNP/NPN logic) at terminal 1 for START/STOP functions, and 4 additional digital inputs at terminals 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). It is designed with a built-in EMC filter, is intended for indoor use only, and utilizes natural convection cooling without a fan. The supply voltage is rated at 400Vac / 480Vac, with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). This model does not include a communication interface. The rated current is 5.5A at 400Vac and 4.8A at 480Vac, for a 3-phase network. It has a rated active power of 2.2kW and a rated power of 3HP for both 400-480Vac. | Lenze | $1,007.92 | Quick Quote | ||
ESV152N04TXB Lenze ESV152N04TXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H191mm x W99mm x D138mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs (PNP/NPN logic) at terminals 1 START/STOP, 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size G2, it supports a supply voltage of 400Vac / 480Vac, network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 4A at 400Vac and 3.5A at 480Vac, for a 3-phase network. Rated active power is 1.5kW and rated power is 2HP for 400-480Vac. | Lenze | $570.64 | Quick Quote | ||
ESV222N02YXC Lenze ESV222N02YXC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40 °C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65. The dimensions are H203mm x W181mm x D172mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs (PNP/NPN logic) at terminals 1 START/STOP, 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only, it has a frame size S1 with natural convection cooling (fan-less). The supply voltage is 240Vac, with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). It does not include a communication interface. The rated current is 9.6A at 240Vac, supporting both single-phase and 3-phase networks. The rated active power is 2.2kW (240Vac), equivalent to 3HP (240Vac). | Lenze | $875.61 | Quick Quote | ||
ESV223N04TXB Lenze ESV223N04TXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H318mm x W176mm x D205mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs including 1 x digital input (PNP/NPN logic) at terminal 1 for START/STOP, and 1 x digital input each at terminals 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size J1, it supports a supply voltage of 400Vac / 480Vac, network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 46A (400Vac) and 40A (480Vac), for a 3-phase network. It offers a rated active power of 22kW and rated power of 30HP for 400-480Vac. | Lenze | $3,180.01 | Quick Quote | ||
ESV371N04TLC Lenze ESV371N04TLC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, alongside 1 x analog input (0-10Vdc) at terminal 5 and 1 x analog input (4-20mA) at terminal 25. The digital inputs consist of 1 x digital input (PNP/NPN logic) at terminal 1 for START/STOP functions, and 1 x digital input each at terminals 13A, 13B, 13C, and 13D. Protection functions include earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Its design incorporates a built-in EMC filter, a built-in disconnect switch, and utilizes natural convection cooling (fan-less) suitable for indoor use only. The supply voltage is rated at 400Vac / 480Vac with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). It does not have a communication interface. The rated current is 1.3A at 400Vac and 1.1A at 480Vac, for a 3-phase network. The rated active power is 0.37kW, and the rated power is 1/2HP for both 400-480Vac. | Lenze | $923.18 | Quick Quote | ||
ESV552N04TXB Lenze ESV552N04TXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H250mm x W130mm x D160mm. It includes 1 digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 analog input (0-10Vdc) at terminal 5, 1 analog input (4-20mA) at terminal 25, and multiple digital inputs (PNP/NPN logic) at terminals 1 START/STOP, 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size H1, it supports a supply voltage of 400Vac / 480Vac, network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 12.6A at 400Vac and 11A at 480Vac, for a 3-phase network. It has a rated active power of 5.5kW and rated power of 7-1/2HP for 400-480Vac. | Lenze | $958.50 | Quick Quote |