All categories
Variable Frequency Drives (VFD)
Found 3,030 products
Lenze ESV371N04TXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H190mm x W99mm x D111mm. It also includes 1 digital output (NPN; 24Vdc / 50mA) at Terminal 14, 2 analog inputs (0-10Vdc at terminal 5 and 4-20mA at terminal 25), and 4 digital inputs (PNP/NPN logic at terminal 1 for START/STOP, and terminals 13A, 13B, 13C, 13D). Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size G1, it supports a supply voltage of 400Vac / 480Vac, network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 1.3A at 400Vac and 1.1A at 480Vac, for a 3-phase network. It delivers a rated active power of 0.37kW and a rated power of 1/2HP for 400-480Vac.
Quick Quote
NIDEC F600-06200500A10101AB103 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for 3-phase input with a supply voltage range of 200Vac-240Vac, specifically 220Vac or 230Vac, and operates on a 60 Hz network frequency. It features a rated current of 50A and rated active power of 11kW, equivalent to 15HP under normal duty. The device is equipped with 1 analog input (4-20mA / 0-10Vdc; single-ended), 1 analog output (0-10Vdc), 3 digital inputs (24Vdc), 3 additional digital inputs (0-24Vdc; configurable), and 2 digital outputs (240Vac; relay contact type). It has an IP20 degree of protection, operates within an ambient air temperature range of -20°C to +40°C, and supports Modbus RTU communication protocol. The F600 series inverter, with dimensions of frame size 6 H15.4" x W8.3" x D8.9" (H391mm x W210mm x D227mm), incorporates a built-in brake transistor, internal line choke, and air cooling design for its operation.
Quick Quote
NIDEC SP1204 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed with a single Safe Torque Off (STO) and air cooling. It features a frame size 1 with dimensions of H15.2" x W3.93" x D8.62" (H386mm x W100mm x D219mm), and operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac). The rated current is 11A for Normal duty and 10.6A for Heavy-duty, with wall-mounted installation. It is designed to operate within an ambient air temperature range of 0°C to +40°C and has a degree of protection of IP20 NEMA 1. The SP1204 supports Modbus RTU RS-485 communication protocol, with a network frequency of 48-65 Hz (Supply input) and 0-550 Hz (output). It includes 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), 3 x digital inputs (0-24Vdc), and 3 x digital inputs (0-24Vdc). The analog inputs consist of 1 x analog input (-9.8Vdc...9.8Vdc; differential) and 2 x analog inputs (0-20mA / 4-20mA / -9.8Vdc...9.8Vdc; single-ended), while the analog outputs include 2 x analog outputs (0-20mA / 4-20mA / -10Vdc...10Vdc; single-ended). The rated active power is 3kW for Normal duty and 2.2kW for Heavy-duty, with a rated power of 3HP for both Normal and Heavy-duty operations. It is designed for a 3-phase input network.
Quick Quote
NIDEC C300-06400470A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C300 series designed with dual Safe Torque Off (STO) and air cooling. It operates on a supply voltage of 380Vac-480Vac, including 400Vac and 415Vac, within a frame size of 6 measuring H15.39" x W8.27" x D8.94" (H291mm x W210mm x D227mm). This model offers an IP20 NEMA 1 degree of protection and supports a rated current of 63A under normal duty and 47A under heavy-duty conditions. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency range of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation spans from -20°C to +60°C. It features 1 analog output (10Vdc; source; single-ended), 5 digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 digital outputs (one 50mA / 0-24Vdc; source; PWM and one 2A / 240Vac; source; relay contact type). Additionally, it includes 2 analog inputs (one 0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution and one 0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 30kW for normal duty and 22kW for heavy-duty, corresponding to a rated power of 40HP and 30HP, respectively.
Quick Quote
Lenze ESV751N02SFC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65. It also includes 1 digital output (NPN; 24Vdc / 50mA) at Terminal 14, alongside 1 analog input (0-10Vdc) at terminal 5 and 1 analog input (4-20mA) at terminal 25. The digital inputs consist of 1 x digital input (PNP/NPN logic) at terminal 1 for START/STOP functions, and additional digital inputs at terminals 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). It is designed with a built-in EMC filter, is intended for indoor use only, and utilizes natural convection cooling without a fan. The supply voltage is 240Vac, with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). This model does not include a communication interface, has a rated current of 4.2A at 240Vac, operates on a single-phase / 1P network, and offers a rated active power of 0.75kW (240Vac) or 1HP (240Vac).
Quick Quote
Lenze ESV402N02TXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H191mm x W99mm x D147mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs (PNP/NPN logic) at terminals 1 START/STOP, 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size G3, it has a supply voltage of 240Vac, network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 16.5A at 240Vac, for a 3-phase network, with a rated active power of 4kW and rated power of 5HP at 240Vac.
Quick Quote
Lenze ESV402N04TMC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65. The dimensions are H330mm x W228mm x D226mm. It includes 1 digital output (NPN; 24Vdc / 50mA) at Terminal 14, 2 analog inputs (1 x 0-10Vdc at terminal 5 and 1 x 4-20mA at terminal 25), and 5 digital inputs (1 x PNP/NPN logic at terminal 1 for START/STOP, and 1 each at terminals 13A, 13B, 13C, and 13D). Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). It is designed with a built-in disconnect switch for indoor use only, featuring a frame size AC1 with natural convection cooling (fan-less). The supply voltage is 400Vac / 480Vac with a network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 9.4A at 400Vac and 8.2A at 480Vac, for a 3-phase network. The rated active power is 4kW, and the rated power is 5HP for both 400-480Vac.
Quick Quote
Lenze ESV112N02YXE is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65, ensuring durability in various environments. The dimensions are H203mm x W160mm x D160mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, and its analog inputs consist of 1 x analog input (0-10Vdc) at terminal 5 and 1 x analog input (4-20mA) at terminal 25. Digital inputs include 1 x digital input (PNP/NPN logic) at terminal 1 for START/STOP functions, and additional digital inputs at terminals 13A, 13B, 13C, and 13D. Protection functions cover a wide range of issues such as earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for both indoor and outdoor use, it features a frame size R2 with natural convection cooling (fan-less). The supply voltage is 240Vac with a network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 6A at 240Vac, suitable for single-phase / 1P or 3-phase (3P / 3AC) networks, with a rated active power of 1.1kW and rated power of 1-1/2HP at 240Vac.
Quick Quote
Lenze ESV222N02YXE is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65, ensuring durability in various environments. The dimensions are H203mm x W181mm x D172mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, and its analog inputs consist of 1 x analog input (0-10Vdc) at terminal 5 and 1 x analog input (4-20mA) at terminal 25. Digital inputs include 1 x digital input (PNP/NPN logic) at terminal 1 for START/STOP functions, and additional digital inputs at terminals 13A, 13B, 13C, and 13D. Protection functions cover a wide range of issues including earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for both indoor and outdoor use, it features a frame size S1 with natural convection cooling (fan-less). The supply voltage is 240Vac, with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). It does not include a communication interface. The rated current is 9.6A at 240Vac, supporting both single-phase / 1P and 3-phase (3P / 3AC) networks. The rated active power is 2.2kW (240Vac), with a rated power of 3HP (240Vac).
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
ESV371N04TXB Lenze ESV371N04TXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H190mm x W99mm x D111mm. It also includes 1 digital output (NPN; 24Vdc / 50mA) at Terminal 14, 2 analog inputs (0-10Vdc at terminal 5 and 4-20mA at terminal 25), and 4 digital inputs (PNP/NPN logic at terminal 1 for START/STOP, and terminals 13A, 13B, 13C, 13D). Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size G1, it supports a supply voltage of 400Vac / 480Vac, network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 1.3A at 400Vac and 1.1A at 480Vac, for a 3-phase network. It delivers a rated active power of 0.37kW and a rated power of 1/2HP for 400-480Vac. | Lenze | $459.19 | Quick Quote | ||
F600-06200500A10101AB103 NIDEC F600-06200500A10101AB103 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for 3-phase input with a supply voltage range of 200Vac-240Vac, specifically 220Vac or 230Vac, and operates on a 60 Hz network frequency. It features a rated current of 50A and rated active power of 11kW, equivalent to 15HP under normal duty. The device is equipped with 1 analog input (4-20mA / 0-10Vdc; single-ended), 1 analog output (0-10Vdc), 3 digital inputs (24Vdc), 3 additional digital inputs (0-24Vdc; configurable), and 2 digital outputs (240Vac; relay contact type). It has an IP20 degree of protection, operates within an ambient air temperature range of -20°C to +40°C, and supports Modbus RTU communication protocol. The F600 series inverter, with dimensions of frame size 6 H15.4" x W8.3" x D8.9" (H391mm x W210mm x D227mm), incorporates a built-in brake transistor, internal line choke, and air cooling design for its operation. | Nidec | $1,903.00 | Quick Quote | ||
SP1204 NIDEC SP1204 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed with a single Safe Torque Off (STO) and air cooling. It features a frame size 1 with dimensions of H15.2" x W3.93" x D8.62" (H386mm x W100mm x D219mm), and operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac). The rated current is 11A for Normal duty and 10.6A for Heavy-duty, with wall-mounted installation. It is designed to operate within an ambient air temperature range of 0°C to +40°C and has a degree of protection of IP20 NEMA 1. The SP1204 supports Modbus RTU RS-485 communication protocol, with a network frequency of 48-65 Hz (Supply input) and 0-550 Hz (output). It includes 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), 3 x digital inputs (0-24Vdc), and 3 x digital inputs (0-24Vdc). The analog inputs consist of 1 x analog input (-9.8Vdc...9.8Vdc; differential) and 2 x analog inputs (0-20mA / 4-20mA / -9.8Vdc...9.8Vdc; single-ended), while the analog outputs include 2 x analog outputs (0-20mA / 4-20mA / -10Vdc...10Vdc; single-ended). The rated active power is 3kW for Normal duty and 2.2kW for Heavy-duty, with a rated power of 3HP for both Normal and Heavy-duty operations. It is designed for a 3-phase input network. | Nidec | $1,605.00 | Quick Quote | ||
C300-06400470A10101AB100 NIDEC C300-06400470A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C300 series designed with dual Safe Torque Off (STO) and air cooling. It operates on a supply voltage of 380Vac-480Vac, including 400Vac and 415Vac, within a frame size of 6 measuring H15.39" x W8.27" x D8.94" (H291mm x W210mm x D227mm). This model offers an IP20 NEMA 1 degree of protection and supports a rated current of 63A under normal duty and 47A under heavy-duty conditions. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency range of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation spans from -20°C to +60°C. It features 1 analog output (10Vdc; source; single-ended), 5 digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 digital outputs (one 50mA / 0-24Vdc; source; PWM and one 2A / 240Vac; source; relay contact type). Additionally, it includes 2 analog inputs (one 0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution and one 0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 30kW for normal duty and 22kW for heavy-duty, corresponding to a rated power of 40HP and 30HP, respectively. | Nidec | $3,872.00 | Quick Quote | ||
ESV751N02SFC Lenze ESV751N02SFC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65. It also includes 1 digital output (NPN; 24Vdc / 50mA) at Terminal 14, alongside 1 analog input (0-10Vdc) at terminal 5 and 1 analog input (4-20mA) at terminal 25. The digital inputs consist of 1 x digital input (PNP/NPN logic) at terminal 1 for START/STOP functions, and additional digital inputs at terminals 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). It is designed with a built-in EMC filter, is intended for indoor use only, and utilizes natural convection cooling without a fan. The supply voltage is 240Vac, with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). This model does not include a communication interface, has a rated current of 4.2A at 240Vac, operates on a single-phase / 1P network, and offers a rated active power of 0.75kW (240Vac) or 1HP (240Vac). | Lenze | $642.23 | Quick Quote | ||
I55AP240F00711K00S Lenze I55AP240F00711K00S | Lenze | $1,159.20 | Quick Quote | ||
ESV402N02TXB Lenze ESV402N02TXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H191mm x W99mm x D147mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs (PNP/NPN logic) at terminals 1 START/STOP, 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size G3, it has a supply voltage of 240Vac, network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 16.5A at 240Vac, for a 3-phase network, with a rated active power of 4kW and rated power of 5HP at 240Vac. | Lenze | $722.48 | Quick Quote | ||
ESV402N04TMC Lenze ESV402N04TMC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65. The dimensions are H330mm x W228mm x D226mm. It includes 1 digital output (NPN; 24Vdc / 50mA) at Terminal 14, 2 analog inputs (1 x 0-10Vdc at terminal 5 and 1 x 4-20mA at terminal 25), and 5 digital inputs (1 x PNP/NPN logic at terminal 1 for START/STOP, and 1 each at terminals 13A, 13B, 13C, and 13D). Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). It is designed with a built-in disconnect switch for indoor use only, featuring a frame size AC1 with natural convection cooling (fan-less). The supply voltage is 400Vac / 480Vac with a network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 9.4A at 400Vac and 8.2A at 480Vac, for a 3-phase network. The rated active power is 4kW, and the rated power is 5HP for both 400-480Vac. | Lenze | $1,422.69 | Quick Quote | ||
ESV112N02YXE Lenze ESV112N02YXE is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65, ensuring durability in various environments. The dimensions are H203mm x W160mm x D160mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, and its analog inputs consist of 1 x analog input (0-10Vdc) at terminal 5 and 1 x analog input (4-20mA) at terminal 25. Digital inputs include 1 x digital input (PNP/NPN logic) at terminal 1 for START/STOP functions, and additional digital inputs at terminals 13A, 13B, 13C, and 13D. Protection functions cover a wide range of issues such as earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for both indoor and outdoor use, it features a frame size R2 with natural convection cooling (fan-less). The supply voltage is 240Vac with a network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 6A at 240Vac, suitable for single-phase / 1P or 3-phase (3P / 3AC) networks, with a rated active power of 1.1kW and rated power of 1-1/2HP at 240Vac. | Lenze | $763.92 | Quick Quote | ||
ESV222N02YXE Lenze ESV222N02YXE is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65, ensuring durability in various environments. The dimensions are H203mm x W181mm x D172mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, and its analog inputs consist of 1 x analog input (0-10Vdc) at terminal 5 and 1 x analog input (4-20mA) at terminal 25. Digital inputs include 1 x digital input (PNP/NPN logic) at terminal 1 for START/STOP functions, and additional digital inputs at terminals 13A, 13B, 13C, and 13D. Protection functions cover a wide range of issues including earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for both indoor and outdoor use, it features a frame size S1 with natural convection cooling (fan-less). The supply voltage is 240Vac, with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). It does not include a communication interface. The rated current is 9.6A at 240Vac, supporting both single-phase / 1P and 3-phase (3P / 3AC) networks. The rated active power is 2.2kW (240Vac), with a rated power of 3HP (240Vac). | Lenze | $1,021.90 | Quick Quote |