Isolating switching amplifier, 4-channel, , 5 relay outputs (NO), Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Common alarm output, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, CSA, TR CU, INMETRO, TIIS, NEPSI, Installation in zone 2
Quick Quote
Trip amplifier, 1-channel, , Monitors 3 limit values at a current or voltage input, Power supply of 2-wire or 3-wire transmitters/sensors, Input circuit: 0/4…20 mA; 0/2…10 V, Output circuit: 3 independent limit value relays, Limit value relay adjusted via rotary coding switches, Hysteresis and relay outputs adjusted via DIP switch, Universal operating voltage, Complete galvanic isolation, Input reverse-polarity protected, , C, FM, US, TR CU
Quick Quote
Isolating switching amplifier, 2-channel, , NC mode, Short-circuit protected PNP transistor outputs, Complete galvanic isolation, Input reverse-polarity protected
Quick Quote
Level controller, 1-channel, , Responsivity: 0.2…100 k, Ω, Hysteresis: 10%, Output: 2 relays with 1 changeover contact, Electronic switching of electrodes, Switch-on/off delay 0…20 s, separately adjustable, Reliable distinction between foam and liquid, Galvanic isolation of input circuits, output circuits and power supply
Quick Quote
Isolating transducer, 1-channel, , Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, Male connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Temperature measuring amplifier, 2-channel, , Input circuits monitored for wire break and short circuit, Parameterized via PC, Complete galvanic isolation, Removable screw terminals, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Isolating switching amplifier, 1-channel, , Transistor output (≤10 kHz), Transistor alarm output, Switchable: Alarm output or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, KOSHA, TIIS, TR CU EAC, Installation in zone 2, SIL 2
Quick Quote
Isolating switching amplifier, 2-channel, , Isolating switching amplifier, 2-channel, Line monitoring for wire break / short circuit, PNP transistor output NC, Complete galvanic isolation, Input reverse-polarity protected, Protection class IP67, Connection with M12 male connectors, ATEX, C, FM, US, IECEx, Use in Zone 2/22
Quick Quote
Isolating switching amplifier, 2-channel, , 2 transistor outputs (≤ 10kHz), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Analog Signal Isolator, 2-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, HART transparent, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, cFM, cUL,NEPSI, INMETRO, Kosha, TR CU EAC CMI, TIIS, Russia Pattern Approval, Installation in zone 2, SIL 2
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
IM1-451EX-R Isolating switching amplifier, 4-channel, , 5 relay outputs (NO), Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Common alarm output, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, CSA, TR CU, INMETRO, TIIS, NEPSI, Installation in zone 2 | Turck | $614.00 | Quick Quote | ||
IM43-13-R Trip amplifier, 1-channel, , Monitors 3 limit values at a current or voltage input, Power supply of 2-wire or 3-wire transmitters/sensors, Input circuit: 0/4…20 mA; 0/2…10 V, Output circuit: 3 independent limit value relays, Limit value relay adjusted via rotary coding switches, Hysteresis and relay outputs adjusted via DIP switch, Universal operating voltage, Complete galvanic isolation, Input reverse-polarity protected, , C, FM, US, TR CU | Turck | $441.30 | Quick Quote | ||
MK1-2RP/24VDC Isolating switching amplifier, 2-channel, , NC mode, Short-circuit protected PNP transistor outputs, Complete galvanic isolation, Input reverse-polarity protected | Turck | $174.70 | Quick Quote | ||
MK91-121-R/24VDC Level controller, 1-channel, , Responsivity: 0.2…100 k, Ω, Hysteresis: 10%, Output: 2 relays with 1 changeover contact, Electronic switching of electrodes, Switch-on/off delay 0…20 s, separately adjustable, Reliable distinction between foam and liquid, Galvanic isolation of input circuits, output circuits and power supply | Turck | $487.00 | Quick Quote | ||
IM12-AI01-1I-1IU-HPR/24VDC/CC Isolating transducer, 1-channel, , Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, Male connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IM12-TI01-2RTDR-2I-C0/24VDC Temperature measuring amplifier, 2-channel, , Input circuits monitored for wire break and short circuit, Parameterized via PC, Complete galvanic isolation, Removable screw terminals, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IMX12-DI03-1S-2T-SPR/24VDC/CC Isolating switching amplifier, 1-channel, , Transistor output (≤10 kHz), Transistor alarm output, Switchable: Alarm output or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, KOSHA, TIIS, TR CU EAC, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IMC-DI-22EX-PNC/24VDC Isolating switching amplifier, 2-channel, , Isolating switching amplifier, 2-channel, Line monitoring for wire break / short circuit, PNP transistor output NC, Complete galvanic isolation, Input reverse-polarity protected, Protection class IP67, Connection with M12 male connectors, ATEX, C, FM, US, IECEx, Use in Zone 2/22 | Turck | Quick Quote | |||
IM12-DI01-2S-2T-0/24VDC Isolating switching amplifier, 2-channel, , 2 transistor outputs (≤ 10kHz), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IMX12-AO01-2I-2I-HPR/24VDC/CC Analog Signal Isolator, 2-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, HART transparent, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, cFM, cUL,NEPSI, INMETRO, Kosha, TR CU EAC CMI, TIIS, Russia Pattern Approval, Installation in zone 2, SIL 2 | Turck | Quick Quote |