Wago 249-117 is a cover designed to function as an end stop on DIN-35 rails, including both 35 x 15 and 35 x 7.5 sizes. It features a rated impulse voltage (Uimp) of 10 mm and is constructed from Polyamide (PA) 66. The dimensions of this part are H44mm x W10mm x D35mm, and it comes in gray.
90 in stock
24 hours
Wago 280-588/280-323 is a terminal designed for sensor terminal block applications, featuring CAGE-CLAMP spring connections. It supports a rated current of 5A (IEC), 6.3A (IEC), 6A (UL), and 15A (CSA). This quadruple-deck terminal is pluggable-disconnect with a built-in orange end plate, ensuring the terminal is closed on both sides, and has colored wire entry specifically for PNP-(high-side) switching sensors. It is designed for a rated impulse voltage (Uimp) of 6 mm and accommodates 4-conductors with a net width suitable for DIN-35 rail control voltage (AC). The terminal's power consumption is colored gray, and it has dimensions of H90.5mm x W6mm x D63.5mm, making it compatible with 0.08mm2 to 2.5mm2 fine stranded or solid conductors and #28AWG to #12AWG fine stranded or solid conductors. The terminal block is made from Polyamide (PA) 66, includes 6-wires (6 clamps) for normally closed (NC) auxiliary contacts, and is rated for (IEC) 125 V, (IEC) 250 V, (UL) 300 V, and (CSA) 300 V.
6 in stock
24 hours
Schneider Electric LC1D326BD is a magnetic contactor from the Deca sub-range, designed with ring-lugs connections and three poles (3P; 3NO). It has a rated current of 50A for AC-1 and 32A for 440Vac in AC-3, with a mounting mode suitable for DIN rail installations. The net width of the contactor is 45 mm, and it offers a degree of protection rated at IP20. The control voltage (DC) ranges from 18-30Vdc, with a nominal 24Vdc, and the rated operating voltage (Ue) is up to 690 V. This contactor includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV, and it supports rated active power ranging from 7.5kW to 18.5kW across various AC-3 voltage levels. The rated power in horsepower (HP) varies from 2HP to 25HP, depending on the voltage and phase, suitable for both single-phase and three-phase applications under UL/CSA standards. The mechanical durability of the LC1D326BD is rated at 15 million operations at no load, and its electrical durability with load is 1.6 million operations. The rated voltage (AC) for phase-to-phase connections is 690 V.
3 in stock
24 hours
Schneider Electric M9F21116 is a Miniature Circuit Breaker (MCB) within the C60SP sub-range, designed for a single pole configuration. It features a rated current of 16A and is compliant with UL1077 standards. The MCB has a rated insulation voltage (Ui) of 500V, a DC rated voltage of 60Vdc, and an AC operating voltage (Ue) of 415V. It is capable of handling an impulse voltage (Uimp) of 6kV. The short circuit breaking rating is specified as 14kA AIR at both 120Vac and 240Vac, and 10kA AIR at 277Vac and 65Vdc. For AC applications, the phase-to-neutral rated voltage is 277V. The device protects a single pole and operates with a B tripping curve.
40 in stock
24 hours
Schneider Electric M9F21110 is a Miniature Circuit Breaker (MCB) within the C60SP sub-range, designed to comply with UL1077 standards. It features 1 pole and is rated for a current of 10A. The MCB has a rated insulation voltage (Ui) of 500V, a DC rated voltage of 60Vdc, and an AC operating voltage (Ue) of 415V. It is capable of withstanding an impulse voltage (Uimp) of 6kV. The short circuit breaking rating is specified as 14kA AIR at both 120Vac and 240Vac, and 10kA AIR at 277Vac and 65Vdc. The rated voltage for AC phase-to-neutral is 277V. It protects 1 pole and follows a B tripping curve.
3 in stock
24 hours
Schneider Electric VW3A3616 is a communications unit designed to facilitate Ethernet TCP/IP communication. It supports the Modbus TCP and EtherNet/IP communication protocols, utilizing RJ45 female connectors for both interfaces. The unit is capable of operating at speeds of 10Mbps and 100Mbps, making it suitable for a variety of industrial automation applications.
57 in stock
24 hours
Schneider Electric M9F22102 is a Miniature Circuit Breaker (MCB) within the C60SP sub-range, designed for a single pole configuration. It features a rated current of 2A and is compliant with UL1077 standards. The MCB has a rated insulation voltage (Ui) of 500V, a rated operating voltage (Ue) of 415V, and a rated impulse voltage (Uimp) of 6kV. It supports a rated voltage of 60Vdc and 277V AC phase-to-neutral. The short circuit breaking rating is specified at 14kA AIR for both 120Vac and 240Vac, and 10kA AIR for 277Vac and 65Vdc. The device is equipped with a C tripping curve and protects a single pole.
4 in stock
24 hours
Wago 281-402 is a busbar (comb) designed for insulated adjacent jumper functions. It supports a rated current of 32A and is configured for 2-poles (2P) with a net width. The part is colored gray and has dimensions of W6mm x D8mm. It is constructed from Polyamide (PA) 66, ensuring compatibility with various applications requiring this specific material and size specification.
20 in stock
24 hours
Schneider Electric M9F53230 is a Miniature Circuit Breaker (MCB) within the C60BPR sub-range, designed with a 2 Pole configuration and a rated current of 30A. It features a rated insulation voltage (Ui) of 500 V and a rated impulse voltage (Uimp) of 6 kV. This MCB offers a short circuit breaking rating of 14kA AIR at both 120Vac and 240Vac, and 10kA AIR at 480Y/277Vac and 125Vdc. It is designed for a rated voltage (AC) phase-to-phase of 440 V and protects 2 poles with a D tripping curve. This product is compliant with UL489 standards.
1 in stock
24 hours
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
249-117 Wago 249-117 is a cover designed to function as an end stop on DIN-35 rails, including both 35 x 15 and 35 x 7.5 sizes. It features a rated impulse voltage (Uimp) of 10 mm and is constructed from Polyamide (PA) 66. The dimensions of this part are H44mm x W10mm x D35mm, and it comes in gray. | WAGO | $1.23 | 90 in stock | 24 hours | |
280-588/280-323 Wago 280-588/280-323 is a terminal designed for sensor terminal block applications, featuring CAGE-CLAMP spring connections. It supports a rated current of 5A (IEC), 6.3A (IEC), 6A (UL), and 15A (CSA). This quadruple-deck terminal is pluggable-disconnect with a built-in orange end plate, ensuring the terminal is closed on both sides, and has colored wire entry specifically for PNP-(high-side) switching sensors. It is designed for a rated impulse voltage (Uimp) of 6 mm and accommodates 4-conductors with a net width suitable for DIN-35 rail control voltage (AC). The terminal's power consumption is colored gray, and it has dimensions of H90.5mm x W6mm x D63.5mm, making it compatible with 0.08mm2 to 2.5mm2 fine stranded or solid conductors and #28AWG to #12AWG fine stranded or solid conductors. The terminal block is made from Polyamide (PA) 66, includes 6-wires (6 clamps) for normally closed (NC) auxiliary contacts, and is rated for (IEC) 125 V, (IEC) 250 V, (UL) 300 V, and (CSA) 300 V. | WAGO | $12.42 | 6 in stock | 24 hours | |
LC1D326BD Schneider Electric LC1D326BD is a magnetic contactor from the Deca sub-range, designed with ring-lugs connections and three poles (3P; 3NO). It has a rated current of 50A for AC-1 and 32A for 440Vac in AC-3, with a mounting mode suitable for DIN rail installations. The net width of the contactor is 45 mm, and it offers a degree of protection rated at IP20. The control voltage (DC) ranges from 18-30Vdc, with a nominal 24Vdc, and the rated operating voltage (Ue) is up to 690 V. This contactor includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV, and it supports rated active power ranging from 7.5kW to 18.5kW across various AC-3 voltage levels. The rated power in horsepower (HP) varies from 2HP to 25HP, depending on the voltage and phase, suitable for both single-phase and three-phase applications under UL/CSA standards. The mechanical durability of the LC1D326BD is rated at 15 million operations at no load, and its electrical durability with load is 1.6 million operations. The rated voltage (AC) for phase-to-phase connections is 690 V. | Schneider Electric | $215.00 | 3 in stock | 24 hours | |
2170283 Lapp - 2170283 | Lapp | $1.52 | 178 in stock | 24 hours | |
M9F21116 Schneider Electric M9F21116 is a Miniature Circuit Breaker (MCB) within the C60SP sub-range, designed for a single pole configuration. It features a rated current of 16A and is compliant with UL1077 standards. The MCB has a rated insulation voltage (Ui) of 500V, a DC rated voltage of 60Vdc, and an AC operating voltage (Ue) of 415V. It is capable of handling an impulse voltage (Uimp) of 6kV. The short circuit breaking rating is specified as 14kA AIR at both 120Vac and 240Vac, and 10kA AIR at 277Vac and 65Vdc. For AC applications, the phase-to-neutral rated voltage is 277V. The device protects a single pole and operates with a B tripping curve. | Schneider Electric | $67.65 | 40 in stock | 24 hours | |
M9F21110 Schneider Electric M9F21110 is a Miniature Circuit Breaker (MCB) within the C60SP sub-range, designed to comply with UL1077 standards. It features 1 pole and is rated for a current of 10A. The MCB has a rated insulation voltage (Ui) of 500V, a DC rated voltage of 60Vdc, and an AC operating voltage (Ue) of 415V. It is capable of withstanding an impulse voltage (Uimp) of 6kV. The short circuit breaking rating is specified as 14kA AIR at both 120Vac and 240Vac, and 10kA AIR at 277Vac and 65Vdc. The rated voltage for AC phase-to-neutral is 277V. It protects 1 pole and follows a B tripping curve. | Schneider Electric | $67.65 | 3 in stock | 24 hours | |
VW3A3616 Schneider Electric VW3A3616 is a communications unit designed to facilitate Ethernet TCP/IP communication. It supports the Modbus TCP and EtherNet/IP communication protocols, utilizing RJ45 female connectors for both interfaces. The unit is capable of operating at speeds of 10Mbps and 100Mbps, making it suitable for a variety of industrial automation applications. | Schneider Electric | $309.00 | 57 in stock | 24 hours | |
M9F22102 Schneider Electric M9F22102 is a Miniature Circuit Breaker (MCB) within the C60SP sub-range, designed for a single pole configuration. It features a rated current of 2A and is compliant with UL1077 standards. The MCB has a rated insulation voltage (Ui) of 500V, a rated operating voltage (Ue) of 415V, and a rated impulse voltage (Uimp) of 6kV. It supports a rated voltage of 60Vdc and 277V AC phase-to-neutral. The short circuit breaking rating is specified at 14kA AIR for both 120Vac and 240Vac, and 10kA AIR for 277Vac and 65Vdc. The device is equipped with a C tripping curve and protects a single pole. | Schneider Electric | $101.00 | 4 in stock | 24 hours | |
281-402 Wago 281-402 is a busbar (comb) designed for insulated adjacent jumper functions. It supports a rated current of 32A and is configured for 2-poles (2P) with a net width. The part is colored gray and has dimensions of W6mm x D8mm. It is constructed from Polyamide (PA) 66, ensuring compatibility with various applications requiring this specific material and size specification. | WAGO | $84.00 | 20 in stock | 24 hours | |
M9F53230 Schneider Electric M9F53230 is a Miniature Circuit Breaker (MCB) within the C60BPR sub-range, designed with a 2 Pole configuration and a rated current of 30A. It features a rated insulation voltage (Ui) of 500 V and a rated impulse voltage (Uimp) of 6 kV. This MCB offers a short circuit breaking rating of 14kA AIR at both 120Vac and 240Vac, and 10kA AIR at 480Y/277Vac and 125Vdc. It is designed for a rated voltage (AC) phase-to-phase of 440 V and protects 2 poles with a D tripping curve. This product is compliant with UL489 standards. | Schneider Electric | $273.00 | 1 in stock | 24 hours |