Compact IP20 Multiprotocol Ethernet I/O Station, Master to master data exchange, NAT router, 8 Digital PNP Inputs, , Two separate, electrically isolated Ethernet interfaces, Bi-directional data exchange between two networks, Protocol conversion between EtherNet/IP™, Modbus® TCP and Profinet®, PROFInet® is supported on P2 Ethernet port, 1:1 NAT router, 10 Mbps/100 Mbps supported, 2 RJ45 ports for the Ethernet connection, 24 VDC
Quick Quote
BL Compact Fieldbus Station for EtherCAT, 4 Analog Outputs for Voltage, On-machine Compact fieldbus I/O block, EtherCAT™ slave, Integrated Ethernet Switch, Two 4-pole M12, D-coded, connectors for fieldbus connection, Auto and Fixed addressing, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 4 analog voltage outputs, -10/0…+10 VDC
Quick Quote
BL compact™ fieldbus station for PROFIBUS-DP, 4 Analog Inputs for Current or Voltage and 4 Analog Outputs for Voltage, On-machine Compact fieldbus I/O block, PROFIBUS-DP slave, 9.6 kbps … 12 Mbps, Two 5-pole M12, reverse-keyed, connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 4 analog inputs for current or voltage, 0/4…20 mA or
Quick Quote
BL compact™ fieldbus station for DeviceNet™, 16 Digital NPN Inputs, On-machine Compact fieldbus I/O block, DeviceNet™ slave, 125 / 250 / 500 kbps, Two 5-pole M12 connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 16 digital NPN inputs, 24 VDC
Quick Quote
Compact IP20 Multiprotocol Ethernet I/O Station, 4 Digital NPN Inputs and 4 Configurable Digital NPN Channels, , EtherNet/IP™ Slave, Modbus TCP Slave, PROFINET Slave, Integrated Ethernet Switch, 10 Mbps / 100 Mbps supported, 2 x RJ45 Sockets for Fieldbus Connection, Can be mounted on DIN rail, 4 digital NPN inputs, 4 configurable NPN channels, DI or DO, 24 VDC, 1 A outputs, Protection class IP20
Quick Quote
8 Digital PNP Inputs, 8 Digital PNP Inputs or Analog INputs (Configurable), , 2 non-isolated J1939 ports (250 kb and 500 kb), Node ID: 0-15, Configurable outputs: Ports 1–8 — digital high side, PWM frequency: 100–1200 Hz, Output diagnostics: Short-circuit and overcurrent
Quick Quote
PROFIBUS-PA, IP67 junction box, 4-channel, , Junction box for wall mounting with PVC cable glands M20 x 1.5, Short-circuit protection per drop line/spur, , Integrated terminating resistor (activatable), Cable shielding: Capacitive or direct connection to housing potential selectable via switch, Isolated support terminal for optional protective conductor incorporated in cable, Powder-coated die-cast aluminium housing, Pressure compensation element protects against condensation, Connection of the
Quick Quote
BL compact™ multiprotocol fieldbus station for Industrial Ethernet, 4 Analog Outputs for Current, On-machine Compact fieldbus I/O block, EtherNet/IP™, Modbus® TCP, or PROFINET slave, Integrated Ethernet Switch, 10 Mbps / 100 Mbps supported, Two 4-pole M12, D-coded, connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 4 analog curren
Quick Quote
FOUNDATION fieldbus and PROFIBUS-PA, Multibarrier, 8-channel, , Galvanically separated Ex e bus cables and Ex i outputs, Temperature range: ‐20…+70 °C (‐4 … +158 °F), Integrated terminating resistor (optional activation), output data: 10V/40mA (short-circuit proof), Powder-coated die-cast aluminium housing, Pressure compensation element for protection against condensation, Connection of the housing potential via M5 x 1 bolt, FISCO compliant according to IEC 60079‐11 and Entity
Quick Quote
16 Digital PNP Outputs, , Molded plastic housing, Shock and vibration tested, Fully potted module electronics, Protection class IP67, J1939 Interface, , This block only has 16 separate outputs. All 16 outputs can be switched on at the same time, two outputs at 10 A and the others at 4 A. This module can deliver up to 52 A output power., 2 non-isolated J1939 ports (250 kb and 500 kb), Node ID: 0-15, Configurable outputs: Ports 1–8 — digital high side, PWM frequency: 100–1200 Hz, Output diagnostic
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
FEN20-EN1-DIN Compact IP20 Multiprotocol Ethernet I/O Station, Master to master data exchange, NAT router, 8 Digital PNP Inputs, , Two separate, electrically isolated Ethernet interfaces, Bi-directional data exchange between two networks, Protocol conversion between EtherNet/IP™, Modbus® TCP and Profinet®, PROFInet® is supported on P2 Ethernet port, 1:1 NAT router, 10 Mbps/100 Mbps supported, 2 RJ45 ports for the Ethernet connection, 24 VDC | Turck | Quick Quote | |||
BLCEC-4M12MT-4AO-V BL Compact Fieldbus Station for EtherCAT, 4 Analog Outputs for Voltage, On-machine Compact fieldbus I/O block, EtherCAT™ slave, Integrated Ethernet Switch, Two 4-pole M12, D-coded, connectors for fieldbus connection, Auto and Fixed addressing, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 4 analog voltage outputs, -10/0…+10 VDC | Turck | Quick Quote | |||
BLCDP-4M12MT-4AI4AO-VI BL compact™ fieldbus station for PROFIBUS-DP, 4 Analog Inputs for Current or Voltage and 4 Analog Outputs for Voltage, On-machine Compact fieldbus I/O block, PROFIBUS-DP slave, 9.6 kbps … 12 Mbps, Two 5-pole M12, reverse-keyed, connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 4 analog inputs for current or voltage, 0/4…20 mA or | Turck | Quick Quote | |||
BLCDN-8M12L-8DI-N-8DI-N BL compact™ fieldbus station for DeviceNet™, 16 Digital NPN Inputs, On-machine Compact fieldbus I/O block, DeviceNet™ slave, 125 / 250 / 500 kbps, Two 5-pole M12 connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 16 digital NPN inputs, 24 VDC | Turck | Quick Quote | |||
FEN20-4DIN-4DXN-DIN Compact IP20 Multiprotocol Ethernet I/O Station, 4 Digital NPN Inputs and 4 Configurable Digital NPN Channels, , EtherNet/IP™ Slave, Modbus TCP Slave, PROFINET Slave, Integrated Ethernet Switch, 10 Mbps / 100 Mbps supported, 2 x RJ45 Sockets for Fieldbus Connection, Can be mounted on DIN rail, 4 digital NPN inputs, 4 configurable NPN channels, DI or DO, 24 VDC, 1 A outputs, Protection class IP20 | Turck | Quick Quote | |||
TBCJ-D1-8DI-8DIAI 8 Digital PNP Inputs, 8 Digital PNP Inputs or Analog INputs (Configurable), , 2 non-isolated J1939 ports (250 kb and 500 kb), Node ID: 0-15, Configurable outputs: Ports 1–8 — digital high side, PWM frequency: 100–1200 Hz, Output diagnostics: Short-circuit and overcurrent | Turck | Quick Quote | |||
JBBS-48SC-T415B/EX PROFIBUS-PA, IP67 junction box, 4-channel, , Junction box for wall mounting with PVC cable glands M20 x 1.5, Short-circuit protection per drop line/spur, , Integrated terminating resistor (activatable), Cable shielding: Capacitive or direct connection to housing potential selectable via switch, Isolated support terminal for optional protective conductor incorporated in cable, Powder-coated die-cast aluminium housing, Pressure compensation element protects against condensation, Connection of the | Turck | Quick Quote | |||
BLCEN-4M12LT-2AO-I-2AO-I BL compact™ multiprotocol fieldbus station for Industrial Ethernet, 4 Analog Outputs for Current, On-machine Compact fieldbus I/O block, EtherNet/IP™, Modbus® TCP, or PROFINET slave, Integrated Ethernet Switch, 10 Mbps / 100 Mbps supported, Two 4-pole M12, D-coded, connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 4 analog curren | Turck | Quick Quote | |||
MBD40-T0815/EX/000 FOUNDATION fieldbus and PROFIBUS-PA, Multibarrier, 8-channel, , Galvanically separated Ex e bus cables and Ex i outputs, Temperature range: ‐20…+70 °C (‐4 … +158 °F), Integrated terminating resistor (optional activation), output data: 10V/40mA (short-circuit proof), Powder-coated die-cast aluminium housing, Pressure compensation element for protection against condensation, Connection of the housing potential via M5 x 1 bolt, FISCO compliant according to IEC 60079‐11 and Entity | Turck | Quick Quote | |||
TBCJ-D1-16DOP 16 Digital PNP Outputs, , Molded plastic housing, Shock and vibration tested, Fully potted module electronics, Protection class IP67, J1939 Interface, , This block only has 16 separate outputs. All 16 outputs can be switched on at the same time, two outputs at 10 A and the others at 4 A. This module can deliver up to 52 A output power., 2 non-isolated J1939 ports (250 kb and 500 kb), Node ID: 0-15, Configurable outputs: Ports 1–8 — digital high side, PWM frequency: 100–1200 Hz, Output diagnostic | Turck | Quick Quote |