Schneider Electric LC1D65ASC7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 80A for AC-1 and 65A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection rated at IP20. The control voltage (AC) ranges from 460-632Vac at 50Hz and 489-632Vac at 60Hz, with a nominal control voltage of 575Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 18.5kW at 220-230Vac to 37kW at 660-690Vac in AC-3. The rated power in horsepower (HP) varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D65ASC7 is rated at 6 million operations at no load, and its electrical durability is rated at 1.4 million operations with load. The rated voltage (AC) for phase-to-phase connections is 690 V.
Quick Quote
Schneider Electric LC1D65AS7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminals and screw connections. It is a 3-pole (3P; 3NO) device with a rated current of 80A (AC-1) and 65A (440Vac; AC-3). Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (AC) ranges from 400-550Vac (500Vac nominal; 50Hz; 0.8...1.1 x Uc) to 425-550Vac (500Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power (kW) spans from 18.5kW at 220-230Vac to 37kW at 660-690Vac (all AC-3), and the rated power (HP) ranges from 5HP at 115Vac to 50HP at 575-600Vac, covering various configurations for single-phase and 3-phase systems under UL/CSA standards. The mechanical durability is rated at 6,000,000 operations, and the electrical durability, with load, is 1,400,000 operations. The rated voltage (AC) for phase-to-phase connections is 690 V.
Quick Quote
Schneider Electric LC1D65ARD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design with screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 80A for AC-1 applications and 65A for 440Vac AC-3 applications. This contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection rated at IP20 and operates with a control voltage (DC) range of 330-550Vdc (440Vdc nominal; 0.75...1.25 x Uc). The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power ranges from 18.5kW at 220-230Vac to 37kW at 660-690Vac in AC-3 category. It also features 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D65ARD is up to 6,000,000 operations, and its electrical durability with load reaches 1,400,000 operations. The rated voltage (AC) phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC1D65A6S7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and ring-lugs connections. This 3-pole (3P; 3NO) contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (AC) range of 400-550Vac (500Vac nominal; 50Hz; 0.8...1.1 x Uc) and 425-550Vac (500Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated current is 80A (AC-1) and 65A (440Vac; AC-3), with a rated impulse voltage (Uimp) of 6 kV. It supports rated active power outputs of 18.5kW (220-230Vac; AC-3) up to 37kW (660-690Vac; AC-3) and rated power (HP) ranging from 5HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA) to 50HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The mechanical durability is rated at 6,000,000 operations, and electrical durability (with load) at 1,400,000 operations. The rated voltage (AC) - phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC1D65A6FC7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design and ring-lugs connections. This 3-pole (3P; 3NO) contactor has a rated current of 80A for AC-1 and 65A for 440Vac in AC-3. It is designed for DIN rail mounting with a net width of 55 mm and offers a degree of protection of IP20. The control voltage (AC) ranges from 102-139Vac at 50Hz and 108-139Vac at 60Hz, with a nominal control voltage of 127Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 18.5kW at 220-230Vac to 37kW at 660-690Vac in AC-3. The rated power in horsepower (HP) varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D65A6FC7 is rated at 6 million operations at no load, and its electrical durability is rated at 1.4 million operations with load. The rated voltage (AC) for phase-to-phase connections is 690 V.
Quick Quote
Schneider Electric LC1D65A3UD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). This contactor is designed for a rated current of 80A under AC-1 conditions and 65A at 440Vac under AC-3 conditions. It supports DIN rail mounting and has a net width of 55 mm. The LC1D65A3UD offers an IP20 degree of protection and operates with a control voltage range of 187.5-312.5Vdc (250Vdc nominal; 0.75...1.25 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 18.5kW at 220-230Vac to 37kW at 660-690Vac under AC-3 conditions. It also features 1 normally closed (NC) auxiliary contact with 1NO+1NC instantaneous auxiliary contacts type. The rated power in horsepower (HP) varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. Its mechanical durability is rated at 6 million operations, and its electrical durability with load is 1.4 million operations. The rated voltage for phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC1D65A3SD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). This contactor is designed for a rated current of 80A under AC-1 conditions and 65A at 440Vac under AC-3 conditions. It supports DIN rail mounting and has a net width of 55 mm. The LC1D65A3SD offers an IP20 degree of protection and operates with a control voltage of 54-90Vdc (72Vdc nominal; 0.75...1.25 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 18.5kW at 220-230Vac to 37kW at 660-690Vac under AC-3 conditions. It also features 1 normally closed (NC) auxiliary contact and instantaneous auxiliary contacts type of 1NO+1NC. The rated power in horsepower (HP) varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, according to UL/CSA standards. Its mechanical durability is rated at 6,000,000 operations, and its electrical durability with load is 1,400,000 operations. The rated voltage (AC) phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC1D65A3R7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). The contactor is rated for currents of 80A under AC-1 conditions and 65A at 440Vac under AC-3 conditions. It is designed for DIN rail mounting and has a net width of 55 mm. The degree of protection provided is IP20. The control voltage (AC) ranges from 352-484Vac at 50Hz and 374-484Vac at 60Hz, with a nominal control voltage of 440Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 18.5kW at 220-230Vac to 37kW at 660-690Vac under AC-3 conditions. The rated power in horsepower (HP) varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the contactor is up to 6,000,000 operations, and its electrical durability with load reaches 1,400,000 operations. The rated voltage (AC) for phase-to-phase connections is 690 V.
Quick Quote
Schneider Electric LC1D65A3K7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). The contactor is rated for currents of 80A under AC-1 conditions and 65A at 440Vac under AC-3 conditions. It is designed for DIN rail mounting and has a net width of 55 mm. The degree of protection provided is IP20. Control voltage ranges from 80-110Vac at 50Hz and 85-110Vac at 60Hz, with a nominal control voltage of 100Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with a contact type of 1NO+1NC instantaneous auxiliaries. The rated impulse voltage (Uimp) is 6 kV. Rated active power varies with voltage, reaching up to 37kW for several voltage ranges in AC-3 condition. Rated power in horsepower (HP) spans from 5HP at 115Vac single-phase to 50HP at 575-600Vac three-phase, under UL/CSA standards. Mechanical durability is rated at 6 million operations at no load, and electrical durability at 1.4 million operations with load. The rated voltage for phase-to-phase connections is 690 V.
Quick Quote
Schneider Electric LC1D65A3G7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). This contactor is designed for a rated current of 80A under AC-1 conditions and 65A at 440Vac under AC-3 conditions. It supports DIN rail mounting and has a net width of 55 mm. The LC1D65A3G7 offers an IP20 degree of protection and operates with a control voltage of 96-132Vac at 50Hz and 102-132Vac at 60Hz. Its rated operating voltage (Ue) reaches up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 18.5kW at 220-230Vac to 37kW at 660-690Vac under AC-3 conditions. It also supports various rated power (HP) levels for different voltages and phases, including 5HP at 115Vac single-phase and up to 50HP at 575-600Vac three-phase, according to UL/CSA standards. The mechanical durability of the LC1D65A3G7 is rated at 6 million operations, and its electrical durability with load is 1.4 million operations. The rated voltage for phase-to-phase connections is 690 V.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
LC1D65ASC7 Schneider Electric LC1D65ASC7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 80A for AC-1 and 65A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection rated at IP20. The control voltage (AC) ranges from 460-632Vac at 50Hz and 489-632Vac at 60Hz, with a nominal control voltage of 575Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 18.5kW at 220-230Vac to 37kW at 660-690Vac in AC-3. The rated power in horsepower (HP) varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D65ASC7 is rated at 6 million operations at no load, and its electrical durability is rated at 1.4 million operations with load. The rated voltage (AC) for phase-to-phase connections is 690 V. | Schneider Electric | Quick Quote | |||
LC1D65AS7 Schneider Electric LC1D65AS7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminals and screw connections. It is a 3-pole (3P; 3NO) device with a rated current of 80A (AC-1) and 65A (440Vac; AC-3). Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (AC) ranges from 400-550Vac (500Vac nominal; 50Hz; 0.8...1.1 x Uc) to 425-550Vac (500Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power (kW) spans from 18.5kW at 220-230Vac to 37kW at 660-690Vac (all AC-3), and the rated power (HP) ranges from 5HP at 115Vac to 50HP at 575-600Vac, covering various configurations for single-phase and 3-phase systems under UL/CSA standards. The mechanical durability is rated at 6,000,000 operations, and the electrical durability, with load, is 1,400,000 operations. The rated voltage (AC) for phase-to-phase connections is 690 V. | Schneider Electric | Quick Quote | |||
LC1D65ARD Schneider Electric LC1D65ARD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design with screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 80A for AC-1 applications and 65A for 440Vac AC-3 applications. This contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection rated at IP20 and operates with a control voltage (DC) range of 330-550Vdc (440Vdc nominal; 0.75...1.25 x Uc). The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power ranges from 18.5kW at 220-230Vac to 37kW at 660-690Vac in AC-3 category. It also features 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D65ARD is up to 6,000,000 operations, and its electrical durability with load reaches 1,400,000 operations. The rated voltage (AC) phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC1D65A6S7 Schneider Electric LC1D65A6S7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and ring-lugs connections. This 3-pole (3P; 3NO) contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (AC) range of 400-550Vac (500Vac nominal; 50Hz; 0.8...1.1 x Uc) and 425-550Vac (500Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated current is 80A (AC-1) and 65A (440Vac; AC-3), with a rated impulse voltage (Uimp) of 6 kV. It supports rated active power outputs of 18.5kW (220-230Vac; AC-3) up to 37kW (660-690Vac; AC-3) and rated power (HP) ranging from 5HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA) to 50HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The mechanical durability is rated at 6,000,000 operations, and electrical durability (with load) at 1,400,000 operations. The rated voltage (AC) - phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC1D65A6FC7 Schneider Electric LC1D65A6FC7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design and ring-lugs connections. This 3-pole (3P; 3NO) contactor has a rated current of 80A for AC-1 and 65A for 440Vac in AC-3. It is designed for DIN rail mounting with a net width of 55 mm and offers a degree of protection of IP20. The control voltage (AC) ranges from 102-139Vac at 50Hz and 108-139Vac at 60Hz, with a nominal control voltage of 127Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 18.5kW at 220-230Vac to 37kW at 660-690Vac in AC-3. The rated power in horsepower (HP) varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D65A6FC7 is rated at 6 million operations at no load, and its electrical durability is rated at 1.4 million operations with load. The rated voltage (AC) for phase-to-phase connections is 690 V. | Schneider Electric | Quick Quote | |||
LC1D65A3UD Schneider Electric LC1D65A3UD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). This contactor is designed for a rated current of 80A under AC-1 conditions and 65A at 440Vac under AC-3 conditions. It supports DIN rail mounting and has a net width of 55 mm. The LC1D65A3UD offers an IP20 degree of protection and operates with a control voltage range of 187.5-312.5Vdc (250Vdc nominal; 0.75...1.25 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 18.5kW at 220-230Vac to 37kW at 660-690Vac under AC-3 conditions. It also features 1 normally closed (NC) auxiliary contact with 1NO+1NC instantaneous auxiliary contacts type. The rated power in horsepower (HP) varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. Its mechanical durability is rated at 6 million operations, and its electrical durability with load is 1.4 million operations. The rated voltage for phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC1D65A3SD Schneider Electric LC1D65A3SD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). This contactor is designed for a rated current of 80A under AC-1 conditions and 65A at 440Vac under AC-3 conditions. It supports DIN rail mounting and has a net width of 55 mm. The LC1D65A3SD offers an IP20 degree of protection and operates with a control voltage of 54-90Vdc (72Vdc nominal; 0.75...1.25 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 18.5kW at 220-230Vac to 37kW at 660-690Vac under AC-3 conditions. It also features 1 normally closed (NC) auxiliary contact and instantaneous auxiliary contacts type of 1NO+1NC. The rated power in horsepower (HP) varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, according to UL/CSA standards. Its mechanical durability is rated at 6,000,000 operations, and its electrical durability with load is 1,400,000 operations. The rated voltage (AC) phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC1D65A3R7 Schneider Electric LC1D65A3R7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). The contactor is rated for currents of 80A under AC-1 conditions and 65A at 440Vac under AC-3 conditions. It is designed for DIN rail mounting and has a net width of 55 mm. The degree of protection provided is IP20. The control voltage (AC) ranges from 352-484Vac at 50Hz and 374-484Vac at 60Hz, with a nominal control voltage of 440Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 18.5kW at 220-230Vac to 37kW at 660-690Vac under AC-3 conditions. The rated power in horsepower (HP) varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the contactor is up to 6,000,000 operations, and its electrical durability with load reaches 1,400,000 operations. The rated voltage (AC) for phase-to-phase connections is 690 V. | Schneider Electric | Quick Quote | |||
LC1D65A3K7 Schneider Electric LC1D65A3K7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). The contactor is rated for currents of 80A under AC-1 conditions and 65A at 440Vac under AC-3 conditions. It is designed for DIN rail mounting and has a net width of 55 mm. The degree of protection provided is IP20. Control voltage ranges from 80-110Vac at 50Hz and 85-110Vac at 60Hz, with a nominal control voltage of 100Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with a contact type of 1NO+1NC instantaneous auxiliaries. The rated impulse voltage (Uimp) is 6 kV. Rated active power varies with voltage, reaching up to 37kW for several voltage ranges in AC-3 condition. Rated power in horsepower (HP) spans from 5HP at 115Vac single-phase to 50HP at 575-600Vac three-phase, under UL/CSA standards. Mechanical durability is rated at 6 million operations at no load, and electrical durability at 1.4 million operations with load. The rated voltage for phase-to-phase connections is 690 V. | Schneider Electric | Quick Quote | |||
LC1D65A3G7 Schneider Electric LC1D65A3G7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). This contactor is designed for a rated current of 80A under AC-1 conditions and 65A at 440Vac under AC-3 conditions. It supports DIN rail mounting and has a net width of 55 mm. The LC1D65A3G7 offers an IP20 degree of protection and operates with a control voltage of 96-132Vac at 50Hz and 102-132Vac at 60Hz. Its rated operating voltage (Ue) reaches up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 18.5kW at 220-230Vac to 37kW at 660-690Vac under AC-3 conditions. It also supports various rated power (HP) levels for different voltages and phases, including 5HP at 115Vac single-phase and up to 50HP at 575-600Vac three-phase, according to UL/CSA standards. The mechanical durability of the LC1D65A3G7 is rated at 6 million operations, and its electrical durability with load is 1.4 million operations. The rated voltage for phase-to-phase connections is 690 V. | Schneider Electric | Quick Quote |