All categories
Circuit Protection Accessories
All categories
Circuit Protection Accessories
ABB 1SAM401907R1004 is a coil designed for tripping applications, featuring a right-side-mounting shunt trip release mechanism with screw-clamp connections. It operates within a supply voltage range of -20 to +60°C and is suitable for ambient air temperatures ranging from -50 to +80°C for storage. This part is equipped for short circuit protection and phase failure, with a rated impulse voltage (Uimp) of 100 mm and poles measuring 37 mm. The rated insulation voltage (Ui) supports its main function alongside a control voltage (AC) specification of 84 mm. It is designed for DIN rail mounting and is compatible with a mounting mode supply voltage of 350-415Vac (50/60Hz), ensuring compatibility with various industrial settings.
Quick Quote
ABB 1SAM401904R1001 is an auxiliary contact designed for left-side-mounting as an auxiliary contact/switch block. It features screw-clamp connections for secure installation. This part operates within an ambient air temperature range for operation of -25 to +70°C and for storage from -50 to +80°C. It is designed with an IP20 control voltage rating, a rated impulse voltage (Uimp) of 6 kV, and a rated insulation voltage (Ui) of 690 V. The net width of the part is 18 mm, and the net depth is 69 mm. It includes short circuit protection and phase failure features for enhanced safety and performance.
Quick Quote
ABB 1SAM401902R1001 is an auxiliary contact designed for left-side-mounting as a switch block with screw-clamp connections. It features 1 Normally Open (NO) auxiliary contact and a configuration of 1NO+1NC contacts. The part operates within an ambient air temperature range for operation of -25 to +70°C and for storage from -50 to +80°C. It has a control voltage classification of IP20, with a rated impulse voltage (Uimp) of 6 kV and rated insulation voltage (Ui) of 690 V, indicating short circuit protection and phase failure capabilities. The net width and poles are specified as 89 mm and 9 mm, respectively, with a net depth of 69 mm. The connection capacity includes 1 NC contact.
Quick Quote
ABB 1SAM301901R1002 is an auxiliary contact designed for right-side-mounting as a signaling contact/switch block with screw-clamp connections. It operates with a rated voltage of 600Vdc and is specifically designed for short-circuit alarm functions. This part features 2 Normally Open (NO) auxiliary contacts, suitable for environments with an ambient air temperature for operation ranging from -25 to +60°C and for storage from -50 to +80°C. The rated impulse voltage (Uimp) stands at 6 kV, and it has a net width of 9 mm. The rated insulation voltage (Ui) is 690 V, indicating its capability for short circuit protection and phase failure. The net depth is 78 mm, and it supports a primary current of 690 V. This auxiliary contact is designed for up to 50,000 operations, with a length indicating durability for the same number of operations.
Quick Quote
Square D by Schneider Electric S29402 is a coil designed for undervoltage release and tripping functions (MN). It operates with a control voltage of 12Vdc. Specifically, it instantaneously opens the circuit breaker when the undervoltage trip supply voltage falls to a range between 35% and 70% of its rated control voltage. The circuit can close when the supply voltage of the undervoltage trip reaches 85% of the rated control voltage.
Quick Quote
Schneider Electric A9N21557 is a Miniature Circuit Breaker (MCB) within the iDPN N Clario sub-range, designed for DIN rail mounting. This 2-pole MCB has a rated current of 16A and features a single protected pole. It offers a tripping curve of type C, ensuring specific disconnection sensitivity. The unit's dimensions are 80 mm in height, 76 mm in depth, and 18 mm in width, with a phase-to-neutral rated voltage of 230 V. Both mechanical and electrical durability are rated for 20,000 operations, indicating its capability for repeated use without load and with load, respectively.
Quick Quote
Schneider Electric A9N21553 is a Miniature Circuit Breaker (MCB) within the iDPN N Clario sub-range. It features a rated current of 2A and is designed for DIN rail mounting. This MCB has 2 poles, with dimensions of 80 mm in height, 76 mm in depth, and 18 mm in width. The rated voltage for phase-to-neutral is 230 V, and it has 1 protected pole. It is characterized by a C tripping curve. Both mechanical and electrical durability are rated at 20,000 operations.
Quick Quote
Schneider Electric A9N18514 is a Miniature Circuit Breaker (MCB) within the C120H sub-range, designed for DIN rail mounting. This MCB features a 3 Pole configuration with all poles protected, and it is rated for a current of 125A. It has a mechanical durability of 20,000 operations at no load and an electrical durability of 5,000 operations with load. The net dimensions are 81 mm in height, 73 mm in depth, and 81 mm in width. It supports a rated voltage of 12-375Vdc, a phase-to-neutral rated voltage of 220 V, and a phase-to-phase rated voltage of 440 V. The tripping curve for this MCB is classified as D.
Quick Quote
Schneider Electric A9N18513 is a Miniature Circuit Breaker (MCB) within the C120H sub-range, designed for DIN rail mounting. This MCB features a 3 Pole configuration with all poles protected, ensuring a comprehensive circuit protection solution. It has a rated current of 100A and offers a mechanical durability of 20,000 operations at no load, alongside an electrical durability of 5,000 operations with load. The net dimensions include a height of 81 mm, a depth of 73 mm, and a width of 81 mm. It supports a wide range of rated voltages, from 12-375Vdc for DC applications and 220V phase-to-neutral and 440V phase-to-phase for AC applications. The tripping curve is classified as D, tailored for specific protection requirements.
Quick Quote
Schneider Electric A9N18512 is a Miniature Circuit Breaker (MCB) within the C120H sub-range, designed for DIN rail mounting. This 3 Pole MCB features a rated current of 80A and offers a mechanical durability of 20,000 operations at no load, with an electrical durability of 5,000 operations with load. It has a net height of 81 mm, a depth of 73 mm, and a width of 81 mm. The A9N18512 supports a rated voltage of 12-375Vdc for DC applications and has rated voltages for AC applications of 220 V phase-to-neutral and 440 V phase-to-phase. All three poles are protected, and it is characterized by a D tripping curve.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
1SAM401907R1004 ABB 1SAM401907R1004 is a coil designed for tripping applications, featuring a right-side-mounting shunt trip release mechanism with screw-clamp connections. It operates within a supply voltage range of -20 to +60°C and is suitable for ambient air temperatures ranging from -50 to +80°C for storage. This part is equipped for short circuit protection and phase failure, with a rated impulse voltage (Uimp) of 100 mm and poles measuring 37 mm. The rated insulation voltage (Ui) supports its main function alongside a control voltage (AC) specification of 84 mm. It is designed for DIN rail mounting and is compatible with a mounting mode supply voltage of 350-415Vac (50/60Hz), ensuring compatibility with various industrial settings. | ABB Control | Quick Quote | |||
1SAM401904R1001 ABB 1SAM401904R1001 is an auxiliary contact designed for left-side-mounting as an auxiliary contact/switch block. It features screw-clamp connections for secure installation. This part operates within an ambient air temperature range for operation of -25 to +70°C and for storage from -50 to +80°C. It is designed with an IP20 control voltage rating, a rated impulse voltage (Uimp) of 6 kV, and a rated insulation voltage (Ui) of 690 V. The net width of the part is 18 mm, and the net depth is 69 mm. It includes short circuit protection and phase failure features for enhanced safety and performance. | ABB Control | Quick Quote | |||
1SAM401902R1001 ABB 1SAM401902R1001 is an auxiliary contact designed for left-side-mounting as a switch block with screw-clamp connections. It features 1 Normally Open (NO) auxiliary contact and a configuration of 1NO+1NC contacts. The part operates within an ambient air temperature range for operation of -25 to +70°C and for storage from -50 to +80°C. It has a control voltage classification of IP20, with a rated impulse voltage (Uimp) of 6 kV and rated insulation voltage (Ui) of 690 V, indicating short circuit protection and phase failure capabilities. The net width and poles are specified as 89 mm and 9 mm, respectively, with a net depth of 69 mm. The connection capacity includes 1 NC contact. | ABB Control | Quick Quote | |||
1SAM301901R1002 ABB 1SAM301901R1002 is an auxiliary contact designed for right-side-mounting as a signaling contact/switch block with screw-clamp connections. It operates with a rated voltage of 600Vdc and is specifically designed for short-circuit alarm functions. This part features 2 Normally Open (NO) auxiliary contacts, suitable for environments with an ambient air temperature for operation ranging from -25 to +60°C and for storage from -50 to +80°C. The rated impulse voltage (Uimp) stands at 6 kV, and it has a net width of 9 mm. The rated insulation voltage (Ui) is 690 V, indicating its capability for short circuit protection and phase failure. The net depth is 78 mm, and it supports a primary current of 690 V. This auxiliary contact is designed for up to 50,000 operations, with a length indicating durability for the same number of operations. | ABB Control | Quick Quote | |||
S29402 Square D by Schneider Electric S29402 is a coil designed for undervoltage release and tripping functions (MN). It operates with a control voltage of 12Vdc. Specifically, it instantaneously opens the circuit breaker when the undervoltage trip supply voltage falls to a range between 35% and 70% of its rated control voltage. The circuit can close when the supply voltage of the undervoltage trip reaches 85% of the rated control voltage. | Schneider Electric | Quick Quote | |||
A9N21557 Schneider Electric A9N21557 is a Miniature Circuit Breaker (MCB) within the iDPN N Clario sub-range, designed for DIN rail mounting. This 2-pole MCB has a rated current of 16A and features a single protected pole. It offers a tripping curve of type C, ensuring specific disconnection sensitivity. The unit's dimensions are 80 mm in height, 76 mm in depth, and 18 mm in width, with a phase-to-neutral rated voltage of 230 V. Both mechanical and electrical durability are rated for 20,000 operations, indicating its capability for repeated use without load and with load, respectively. | Schneider Electric | Quick Quote | |||
A9N21553 Schneider Electric A9N21553 is a Miniature Circuit Breaker (MCB) within the iDPN N Clario sub-range. It features a rated current of 2A and is designed for DIN rail mounting. This MCB has 2 poles, with dimensions of 80 mm in height, 76 mm in depth, and 18 mm in width. The rated voltage for phase-to-neutral is 230 V, and it has 1 protected pole. It is characterized by a C tripping curve. Both mechanical and electrical durability are rated at 20,000 operations. | Schneider Electric | Quick Quote | |||
A9N18514 Schneider Electric A9N18514 is a Miniature Circuit Breaker (MCB) within the C120H sub-range, designed for DIN rail mounting. This MCB features a 3 Pole configuration with all poles protected, and it is rated for a current of 125A. It has a mechanical durability of 20,000 operations at no load and an electrical durability of 5,000 operations with load. The net dimensions are 81 mm in height, 73 mm in depth, and 81 mm in width. It supports a rated voltage of 12-375Vdc, a phase-to-neutral rated voltage of 220 V, and a phase-to-phase rated voltage of 440 V. The tripping curve for this MCB is classified as D. | Schneider Electric | Quick Quote | |||
A9N18513 Schneider Electric A9N18513 is a Miniature Circuit Breaker (MCB) within the C120H sub-range, designed for DIN rail mounting. This MCB features a 3 Pole configuration with all poles protected, ensuring a comprehensive circuit protection solution. It has a rated current of 100A and offers a mechanical durability of 20,000 operations at no load, alongside an electrical durability of 5,000 operations with load. The net dimensions include a height of 81 mm, a depth of 73 mm, and a width of 81 mm. It supports a wide range of rated voltages, from 12-375Vdc for DC applications and 220V phase-to-neutral and 440V phase-to-phase for AC applications. The tripping curve is classified as D, tailored for specific protection requirements. | Schneider Electric | Quick Quote | |||
A9N18512 Schneider Electric A9N18512 is a Miniature Circuit Breaker (MCB) within the C120H sub-range, designed for DIN rail mounting. This 3 Pole MCB features a rated current of 80A and offers a mechanical durability of 20,000 operations at no load, with an electrical durability of 5,000 operations with load. It has a net height of 81 mm, a depth of 73 mm, and a width of 81 mm. The A9N18512 supports a rated voltage of 12-375Vdc for DC applications and has rated voltages for AC applications of 220 V phase-to-neutral and 440 V phase-to-phase. All three poles are protected, and it is characterized by a D tripping curve. | Schneider Electric | Quick Quote |