All categories
Circuit Protection Accessories
Schneider Electric 28956 is a cover designed for terminal shrouds, compatible with both 3 pole and 4 pole configurations.
Quick Quote
Schneider Electric 28944 is a rotary handle designed for lateral control, featuring a red/yellow color scheme.
Quick Quote
Square D by Schneider Electric QOUCP4 is a cover plate designed to fit specific electrical panels and enclosures. This part serves as a protective cover, enhancing the aesthetics and safety of the installation by providing a clean, finished look while preventing direct access to the components it covers.
Quick Quote
Schneider Electric LXD3YC7 is a replacement control coil designed for use with 40A-65A contactors within the Deca sub-range. It is engineered to operate with a control voltage (AC) of 528-726Vac at a nominal 660Vac and 50Hz frequency, with a voltage range of 0.8 to 1.1 times Uc, and 561-726Vac at a nominal 660Vac and 60Hz frequency, with a voltage range of 0.85 to 1.1 times Uc. The coil has an inductance of 90 to 100 mH.
Quick Quote
Schneider Electric LXD3Y7 is a replacement control coil designed for use with 40A-65A contactors within the Deca sub-range. It is engineered to operate with a control voltage (AC) of 552-759Vac at a nominal 690Vac and 50Hz frequency, maintaining a voltage range of 0.8 to 1.1 times Uc. For 60Hz frequency, the control voltage (AC) specification adjusts to 586.5-759Vac, also at a nominal 690Vac, with a voltage range of 0.85 to 1.1 times Uc. The part features an inductance of 98,500 mH.
Quick Quote
Schneider Electric LXD3J5 is a replacement control coil designed for use with 40A-65A contactors within the Deca sub-range. It is engineered to operate with a control voltage of 9.6-13.2Vac at 50Hz (12Vac nominal; 0.8...1.1 times Uc) and 10.2-13.2Vac at 60Hz (12Vac nominal; 0.85...1.1 times Uc). The coil features an inductance of 30 mH.
Quick Quote
Schneider Electric LX9FL925 is a coil (contactor) within the F sub-range, designed as a replacement low-inrush consumption control coil. It operates with a control voltage of 110Vdc and has an inductance of 980 mH.
Quick Quote
Schneider Electric LUCC1XES is a protection unit belonging to the Ultra sub-range, designed to offer advanced control with thermal/magnetic protection (class 10). It features a test push button operable at 48Vac (50/60Hz) or 48-72Vdc and includes both manual and automatic reset capabilities, the latter when used with a communication module. This 1-pole (1P) unit is engineered to protect against thermal overload (class 10), overload current (14.2 x intensity setting), short-circuits (14.2 x max. current), missing or unbalanced phases, and insulation faults. It supports a rated current range of 0.35A-1.4A and offers a degree of protection rated at IP20 and IP40. The LUCC1XES is equipped with 0 Normally Open (NO) auxiliary contacts and 0 Normally Closed (NC) auxiliary contacts, and it is capable of handling a rated active power of 0.25kW at 400/440Vac; 50/60Hz; AC-3.
Quick Quote
Schneider Electric LUCC05ES is a protection unit within the Ultra sub-range, designed with advanced control features. It incorporates thermal and magnetic protection (class 10) with a test push button, operating at 48Vac (50/60Hz) or 48-72Vdc. The unit offers both manual and automatic reset options and can be integrated with a communication module. It is a 1-pole (1P) device, providing protection functions including thermal overload class 10, overload current (14.2 x intensity setting), short-circuits (14.2 x max. current), missing or unbalanced phases, and insulation fault. The rated current ranges from 1.25A to 5A, with a degree of protection rated at IP20 and IP40. It has 0 Normally Open (NO) auxiliary contacts and 0 Normally Closed (NC) auxiliary contacts. The rated active power is 1.5kW at 400/440Vac (50/60Hz; AC-3), 2.2kW at 500Vac (50/60Hz; AC-3), and 3kW at 660/690Vac (50/60Hz; AC-3).
Quick Quote
Schneider Electric LADN209 is an auxiliary contact designed for use within the Deca sub-range. This part functions as both an auxiliary contact block and a switch block, featuring Faston spade connections for connectivity. It is equipped with 2-poles and supports front clip-on mounting for ease of installation. The LADN209 includes 2 Normally Open (NO) auxiliary contacts and does not have Normally Closed (NC) auxiliary contacts.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
28956 Schneider Electric 28956 is a cover designed for terminal shrouds, compatible with both 3 pole and 4 pole configurations. | Schneider Electric | Quick Quote | |||
28944 Schneider Electric 28944 is a rotary handle designed for lateral control, featuring a red/yellow color scheme. | Schneider Electric | Quick Quote | |||
QOUCP4 Square D by Schneider Electric QOUCP4 is a cover plate designed to fit specific electrical panels and enclosures. This part serves as a protective cover, enhancing the aesthetics and safety of the installation by providing a clean, finished look while preventing direct access to the components it covers. | Schneider Electric | Quick Quote | |||
LXD3YC7 Schneider Electric LXD3YC7 is a replacement control coil designed for use with 40A-65A contactors within the Deca sub-range. It is engineered to operate with a control voltage (AC) of 528-726Vac at a nominal 660Vac and 50Hz frequency, with a voltage range of 0.8 to 1.1 times Uc, and 561-726Vac at a nominal 660Vac and 60Hz frequency, with a voltage range of 0.85 to 1.1 times Uc. The coil has an inductance of 90 to 100 mH. | Schneider Electric | Quick Quote | |||
LXD3Y7 Schneider Electric LXD3Y7 is a replacement control coil designed for use with 40A-65A contactors within the Deca sub-range. It is engineered to operate with a control voltage (AC) of 552-759Vac at a nominal 690Vac and 50Hz frequency, maintaining a voltage range of 0.8 to 1.1 times Uc. For 60Hz frequency, the control voltage (AC) specification adjusts to 586.5-759Vac, also at a nominal 690Vac, with a voltage range of 0.85 to 1.1 times Uc. The part features an inductance of 98,500 mH. | Schneider Electric | Quick Quote | |||
LXD3J5 Schneider Electric LXD3J5 is a replacement control coil designed for use with 40A-65A contactors within the Deca sub-range. It is engineered to operate with a control voltage of 9.6-13.2Vac at 50Hz (12Vac nominal; 0.8...1.1 times Uc) and 10.2-13.2Vac at 60Hz (12Vac nominal; 0.85...1.1 times Uc). The coil features an inductance of 30 mH. | Schneider Electric | Quick Quote | |||
LX9FL925 Schneider Electric LX9FL925 is a coil (contactor) within the F sub-range, designed as a replacement low-inrush consumption control coil. It operates with a control voltage of 110Vdc and has an inductance of 980 mH. | Schneider Electric | Quick Quote | |||
LUCC1XES Schneider Electric LUCC1XES is a protection unit belonging to the Ultra sub-range, designed to offer advanced control with thermal/magnetic protection (class 10). It features a test push button operable at 48Vac (50/60Hz) or 48-72Vdc and includes both manual and automatic reset capabilities, the latter when used with a communication module. This 1-pole (1P) unit is engineered to protect against thermal overload (class 10), overload current (14.2 x intensity setting), short-circuits (14.2 x max. current), missing or unbalanced phases, and insulation faults. It supports a rated current range of 0.35A-1.4A and offers a degree of protection rated at IP20 and IP40. The LUCC1XES is equipped with 0 Normally Open (NO) auxiliary contacts and 0 Normally Closed (NC) auxiliary contacts, and it is capable of handling a rated active power of 0.25kW at 400/440Vac; 50/60Hz; AC-3. | Schneider Electric | Quick Quote | |||
LUCC05ES Schneider Electric LUCC05ES is a protection unit within the Ultra sub-range, designed with advanced control features. It incorporates thermal and magnetic protection (class 10) with a test push button, operating at 48Vac (50/60Hz) or 48-72Vdc. The unit offers both manual and automatic reset options and can be integrated with a communication module. It is a 1-pole (1P) device, providing protection functions including thermal overload class 10, overload current (14.2 x intensity setting), short-circuits (14.2 x max. current), missing or unbalanced phases, and insulation fault. The rated current ranges from 1.25A to 5A, with a degree of protection rated at IP20 and IP40. It has 0 Normally Open (NO) auxiliary contacts and 0 Normally Closed (NC) auxiliary contacts. The rated active power is 1.5kW at 400/440Vac (50/60Hz; AC-3), 2.2kW at 500Vac (50/60Hz; AC-3), and 3kW at 660/690Vac (50/60Hz; AC-3). | Schneider Electric | Quick Quote | |||
LADN209 Schneider Electric LADN209 is an auxiliary contact designed for use within the Deca sub-range. This part functions as both an auxiliary contact block and a switch block, featuring Faston spade connections for connectivity. It is equipped with 2-poles and supports front clip-on mounting for ease of installation. The LADN209 includes 2 Normally Open (NO) auxiliary contacts and does not have Normally Closed (NC) auxiliary contacts. | Schneider Electric | Quick Quote |