XCSLF353551M3 Telemecanique Sensors Safety Switches

Telemecanique Sensors XCSLF353551M3 Telemecanique XCSLF353551M3 is a safety lock designed for door, cover, and hood safety guard interlock applications, featuring limit switch locking on energization and unlocking on de-energization with a break before make/slow break function. It is constructed from Zamak for both the head and body, ensuring durability. This part utilizes an M23 connector for its connection type and supports a 19-pin configuration. It offers a degree of protection rated at IP67 and boasts a mechanical durability of 1,000,000 operations at no load. The XCSLF353551M3 operates with 3 poles and has a control voltage of 24 Vac and 24 Vdc. It includes 2 Normally Open (NO) auxiliary contacts and 1 Normally Closed (NC) auxiliary contact, with a rated insulation voltage of 250 V (UL) and 300 V. Visual position indicators are provided by an Orange LED for guard opening and a Green LED for guard locking. The control circuit rated current is 0.75 A for 240Vac (AC-15) and 100mA/0.1 A for 250Vdc (DC-13), with similar ratings for 240Vac (C300) and 250Vdc (R300). It can operate within a temperature range of -25 °C to 70 °C and has an electrical durability of 1,000,000 operations with load. The latching type is solenoid locking (1NC+2NO break before make contact).
Telemecanique Sensors

Part#:XCSLF353551M3

Manufacturer:Telemecanique Sensors

Product Lifecycle:Active

Get a quick Quote!

Telemecanique XCSLF353551M3 is a safety lock designed for door, cover, and hood safety guard interlock applications, featuring limit switch locking on energization and unlocking on de-energization with a break before make/slow break function. It is constructed from Zamak for both the head and body, ensuring durability. This part utilizes an M23 connector for its connection type and supports a 19-pin configuration. It offers a degree of protection rated at IP67 and boasts a mechanical durability of 1,000,000 operations at no load. The XCSLF353551M3 operates with 3 poles and has a control voltage of 24 Vac and 24 Vdc. It includes 2 Normally Open (NO) auxiliary contacts and 1 Normally Closed (NC) auxiliary contact, with a rated insulation voltage of 250 V (UL) and 300 V. Visual position indicators are provided by an Orange LED for guard opening and a Green LED for guard locking. The control circuit rated current is 0.75 A for 240Vac (AC-15) and 100mA/0.1 A for 250Vdc (DC-13), with similar ratings for 240Vac (C300) and 250Vdc (R300). It can operate within a temperature range of -25 °C to 70 °C and has an electrical durability of 1,000,000 operations with load. The latching type is solenoid locking (1NC+2NO break before make contact).

About the manufacturer: Telemecanique Sensors is one of the manufacturers that offers Safety Switches that you can order at Powermatic Associates site. For more than forty years, Telemecanique Sensors, formerly Hyde Park, has been refining ultrasonic technology and has become a leading global provider in this industry. Through the use of advanced ultrasonic technology, Telemecanique designs and manufactures reliable noncontact sensors.

Check out the XCSLF353551M3 Telemecanique Sensors price in the box on the right side or send a quick quote.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


XCSLF353551M3 Description

Telemecanique XCSLF353551M3 is a safety lock designed for door, cover, and hood safety guard interlock applications, featuring limit switch locking on energization and unlocking on de-energization with a break before make/slow break function. It is constructed from Zamak for both the head and body, ensuring durability. This part utilizes an M23 connector for its connection type and supports a 19-pin configuration. It offers a degree of protection rated at IP67 and boasts a mechanical durability of 1,000,000 operations at no load. The XCSLF353551M3 operates with 3 poles and has a control voltage of 24 Vac and 24 Vdc. It includes 2 Normally Open (NO) auxiliary contacts and 1 Normally Closed (NC) auxiliary contact, with a rated insulation voltage of 250 V (UL) and 300 V. Visual position indicators are provided by an Orange LED for guard opening and a Green LED for guard locking. The control circuit rated current is 0.75 A for 240Vac (AC-15) and 100mA/0.1 A for 250Vdc (DC-13), with similar ratings for 240Vac (C300) and 250Vdc (R300). It can operate within a temperature range of -25 °C to 70 °C and has an electrical durability of 1,000,000 operations with load. The latching type is solenoid locking (1NC+2NO break before make contact).


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1