LC3D150F7 Schneider Electric Motor Control Starters

Schneider Electric LC3D150F7 Schneider Electric LC3D150F7 is a plate-mounted motor starter from the Deca sub-range, designed for star-delta (Y-D / wye-delta) starting method. It features screw connections and is equipped with 3 x 3-poles (3x3P; 3x3NO) configuration. The starter has a rated current of 200A for AC-1 applications and 150A for 440Vac in AC-3 applications. It offers plate mounting mode and comes with an IP20 degree of protection. The control voltage (AC) ranges from 88-126Vac (110Vac nominal; 50Hz/60Hz; 0.8...1.15 x Uc), and it operates at a rated operating voltage (Ue) of 1000 V. This starter includes 1 Normally Open (NO) auxiliary contact and 2 Normally Closed (NC) auxiliary contacts, with a rated impulse voltage (Uimp) of 8 kV. The rated active power (kW) is 75kW at 220/230Vac, 132kW at 380/400Vac and 415Vac, and 147kW at 440Vac in AC-3 applications. The contacts type includes 1NC auxiliary for the KM1 star contactor, 1NC auxiliary for the KM2 line contactor, and 1NO auxiliary for the KM3 delta contactor. The rated voltage (AC) for phase-to-phase applications is 1000 V.
Schneider Electric

Part#:LC3D150F7

Manufacturer:Schneider Electric

Product Lifecycle:Active

Get a quick Quote!

Schneider Electric LC3D150F7 is a plate-mounted motor starter from the Deca sub-range, designed for star-delta (Y-D / wye-delta) starting method. It features screw connections and is equipped with 3 x 3-poles (3x3P; 3x3NO) configuration. The starter has a rated current of 200A for AC-1 applications and 150A for 440Vac in AC-3 applications. It offers plate mounting mode and comes with an IP20 degree of protection. The control voltage (AC) ranges from 88-126Vac (110Vac nominal; 50Hz/60Hz; 0.8...1.15 x Uc), and it operates at a rated operating voltage (Ue) of 1000 V. This starter includes 1 Normally Open (NO) auxiliary contact and 2 Normally Closed (NC) auxiliary contacts, with a rated impulse voltage (Uimp) of 8 kV. The rated active power (kW) is 75kW at 220/230Vac, 132kW at 380/400Vac and 415Vac, and 147kW at 440Vac in AC-3 applications. The contacts type includes 1NC auxiliary for the KM1 star contactor, 1NC auxiliary for the KM2 line contactor, and 1NO auxiliary for the KM3 delta contactor. The rated voltage (AC) for phase-to-phase applications is 1000 V.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Motor Control Starters that you can order at Powermatic Associates site. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the LC3D150F7 Schneider Electric price in the box on the right side or send a quick quote.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


LC3D150F7 Description

Schneider Electric LC3D150F7 is a plate-mounted motor starter from the Deca sub-range, designed for star-delta (Y-D / wye-delta) starting method. It features screw connections and is equipped with 3 x 3-poles (3x3P; 3x3NO) configuration. The starter has a rated current of 200A for AC-1 applications and 150A for 440Vac in AC-3 applications. It offers plate mounting mode and comes with an IP20 degree of protection. The control voltage (AC) ranges from 88-126Vac (110Vac nominal; 50Hz/60Hz; 0.8...1.15 x Uc), and it operates at a rated operating voltage (Ue) of 1000 V. This starter includes 1 Normally Open (NO) auxiliary contact and 2 Normally Closed (NC) auxiliary contacts, with a rated impulse voltage (Uimp) of 8 kV. The rated active power (kW) is 75kW at 220/230Vac, 132kW at 380/400Vac and 415Vac, and 147kW at 440Vac in AC-3 applications. The contacts type includes 1NC auxiliary for the KM1 star contactor, 1NC auxiliary for the KM2 line contactor, and 1NO auxiliary for the KM3 delta contactor. The rated voltage (AC) for phase-to-phase applications is 1000 V.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Relevant products

LGL36600U53XENAAUOYH1 Part Image. Manufactured by Schneider Electric.

LGL36600U53XENAAUOYH1

$10,804.80

Verified stock: 2

Square D by Schneider Electric LGL36600U53XENAAUOYH1 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT LGL sub-range. It features a factory-installed 24Vdc undervoltage (U/V) trip release coil and a factory-installed 1A/1B (1NO+1NC) auxiliary switch OF wire harness. Designed for PowerPacT L-Frame, this 3-pole (3P) breaker has a rated current of 600A and operates at a rated voltage of 600Vac and 600Y/347Vac, with a rated insulation voltage (Ui) of 750V. It offers long-time (L), short-time with fixed time delay (S), instantaneous (I), and Zone Selective Interlocking (ZSI) protection functions. The breaker is equipped with lugs on both load and line sides for connection and is designed for individual unit mount on plate. It has a net height of 382mm, width of 153mm, depth of 171mm, and offers a degree of protection of IP40. The operating mode is manual toggle, with protection settings adjustable for overload, short-circuit with time delay, and instantaneous protection against short-circuit. The control voltage for the undervoltage trip coil allows circuit breaker opening at 35% to 70% of its rated control voltage, with closing permitted when the supply voltage reaches 85% of rated control voltage. The rated operating voltage (Ue) is 690V, with a rated impulse voltage (Uimp) of 8kV. The trip current rating is 600 AT, with a frame current rating of 600 AF. It has a short circuit breaking rating of up to 65kA at 240Vac under UL489 standards. The trip unit type is an electronic Micrologic Energy 5.3E (LSI) with an LCD display, offering comprehensive measurement functions for current, voltage, power, energy metering, power quality, and harmonic analysis. The utilisation category is A.

Schneider Electric

LDM36400CU44X Part Image. Manufactured by Schneider Electric.

LDM36400CU44X

$8,969.00

Verified stock: 1

Square D by Schneider Electric LDM36400CU44X is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT LDM sub-range, designed as a PowerPact L-Frame 600 Micrologic 6.3A (LSIG) 3P 400A 600Vac 14kA with a lug connection on the line side and a terminal nut kit for fixed busbar connection on the load side. It features three poles (3P) and offers protection functions including Long-time (L), Short-time with fixed time delay (S), Instantaneous (I), Ground fault (G), and Zone Selective Interlocking (ZSI). The rated current is 400A, with a rated insulation voltage (Ui) of 750V, and it operates at a rated voltage (AC) of 600Vac. This unit is designed for individual unit mount on plate, with dimensions of 382 mm in height, 153 mm in width, and 171 mm in depth. It has a degree of protection of IP40 and operates via a toggle (manual). Protection settings are adjustable, with L protection against overload adjustable from 0.3 to 1 x In (125A to 400A), S protection against short-circuit with time delay adjustable from 1.5 to 10 x Ir (600A to 4000A), I instantaneous protection against short-circuit adjustable from 1.5 to 12 x In (600A to 4800A), and G protection against earth fault adjustable at 0.2 to 1 x In (0.1 to 0.4s time delay). The rated operating voltage (Ue) is 690V, with a rated impulse voltage (Uimp) of 8kV. The trip current rating is 400 AT, with a frame current rating of 600 AF, and a short circuit breaking rating of 25kA at 240Vac, 18kA at 480Vac, and 14kA at 600Vac according to UL489. The trip unit type features electronic technology with a Micrologic 6.3A (LSIG) series, providing LSIG protection and an LCD display. Its measurement function includes current measurements for phases and neutral, RMS instantaneous current, current unbalance between phases, highest RMS current of the three phases, ground fault current, and demand/peak current values on all three phases plus neutral, with a calculation window adjustable between 5-60 minutes. The utilisation category is A.

Schneider Electric

What can I help you find today?

Recommended parts