Pilz PILZ-772010 is a communications unit designed as an expansion/communication module with Ethernet POWERLINK V2 fieldbus interface, functioning as a controlled node. It features potential isolation between the fieldbus and module voltage with functional insulation and a rated surge voltage of 500V. This unit is suitable for DIN rail mounting, specifically on a 35mmx7.5mm horizontal rail, and operates within an ambient air temperature range of 0 to +60°C without forced convection and up to +55°C with it. The unit has a net height of 100 mm, a width of 22.5 mm, and a depth of 110.4 mm, and it connects via an RJ45 connector plug-in/detachable screw or spring-loaded terminals, supporting 2 points per spring-loaded connection with a 9mm stripping length. It belongs to the communication module sub-range, encased in a PC housing, and offers an IP20 degree of protection. The supply voltage ranges from 19.2 to 30Vdc, with a nominal 24Vdc, and an additional 3.23-3.37Vdc (3.3Vdc nominal) for module supply via the base unit. It supports a cross-section of 0.25 to 2.5mm2 for various connection types and consumes 1.2W power from the supply via the base unit, with an additional 0.2W for the module supply. The unit's power dissipation/losses are a maximum of 1.5W, operates with a speed of 100MBit/s for Ethernet POWERLINK V2, and has a current consumption of 60mA from the supply via the base module. It features a time delay of 20ms for supply interruption before de-energization and is designed for storage in ambient air temperatures ranging from -25 to +70°C. The unit includes protection functions such as galvanic isolation and potential isolation, with a rated insulation voltage (Ui) of 30 V.
Quick Quote
Pilz PILZ-773120 is a configurable safety base unit designed for DIN rail mounting, specifically on a 35mmx7.5mm horizontal rail. It operates within an ambient air temperature range of 0 to +60°C without forced convection and up to +55°C with forced convection off. This safety controller features an airgap creepage of 3mm between relay contacts and 5.5mm between relay contacts and other circuits. It offers potential isolation with protective separation, rated at 2500V between SC output and system voltage, and 6000V between relay output and system voltage. The unit is expandable for furnace/burner functions and supports a rated current of 6A for both 24Vdc (DC-1) and 240Vac (AC-1), with specific ratings for other operational modes. Connection options include plug-in/detachable screw or spring-loaded terminals, accommodating various wire sizes and types. The base unit has dimensions of 27mm in width, 94mm in height, and 121mm in depth, with a degree of protection rated at IP20. It requires a supply voltage of 20.4-28.8Vdc (24Vdc nominal) and is constructed from PPO and ABS materials. The PILZ-773120 supports RS-232 communication protocol, has a power consumption profile for different operational states, and offers multiple digital inputs and outputs with specific safety and standard configurations. It includes protection functions such as short-circuit proofing, potential and galvanic isolation, and features a range of response times for various operational parameters.
Quick Quote
Pilz PILZ-773125 is a safety controller designed as a configurable safety base unit or safe small controller. It features airgap creepage distances of 3mm between relay contacts and 5.5mm between relay contacts and other circuits. The unit supports 2 x Ethernet for communication and offers potential isolation with protective separation, having a rated surge voltage of 2500V between SC output and system voltage, and 6000V between relay output and system voltage. It is designed for DIN rail mounting, specifically on a 35mmx7.5mm horizontal rail, and operates within an ambient air temperature range of 0 to +60°C without forced convection and up to +55°C with forced convection off. The net height of the unit is 94mm, and it is expandable for furnace/burner function applications. The rated current specifications include 6A at 24Vdc (DC-1), 6A at 240Vac (AC-1), among others, with connection types accommodating plug-in/detachable screw or spring-loaded terminals. As part of the base unit sub-range, it measures 27mm in width and offers an IP20 degree of protection. The supply voltage requirement is 20.4-28.8Vdc (24Vdc nominal), constructed from PPO bottom housing and ABS front housing materials. It supports a maximum cable length of 1000m per input and 40km overall for test pulse output, with a net width of 135mm. Communication is facilitated via Ethernet, and it accepts various cross-sections for wiring. Power consumption varies with output external power supply up to 192W, with lower consumption for expansion modules and no load conditions. The net depth is 121mm, and it can be stored in temperatures ranging from -25 to +70°C. It features 4 x digital outputs for safety semiconductor outputs, additional outputs for standard auxiliary, safety relay, test pulse, and standard cascading functions. Protection functions include short-circuit proofing, potential isolation, and galvanic isolation. Response times range from 3s for simultaneity channel max to 0.5s for 2-hand circuit simultaneity, with a rated impulse voltage of 6kV and rated insulation voltage of 250V. It supports 20 x safety inputs, with a current consumption of 6A for blow-out fuse or circuit breaker. Time delays and processing times are specified for various operational parameters, ensuring precise control and safety measures.
Quick Quote
Pilz PILZ-773113 is a power supply unit designed for DIN rail mounting, specifically for horizontal placement on top of a hat rail. It operates within an ambient air temperature range of -10 to +55 °C and features screw terminal connections. This unit has a net height of 94 mm, a width of 45 mm, and a depth of 121 mm, encased in an ABS housing. It supports a supply voltage range of 100Vac-240Vac (including 120Vac, 208Vac, 220Vac, 230Vac) and 100Vdc-240Vdc (including 110Vdc, 120Vdc, 220Vdc nom.), with a rated current of 0.62A to 0.79A. The PILZ-773113, part of the PNOZ pps1p sub-range, offers a degree of protection rated at IP20. It has a power consumption of 30 VA, a rated power of 15W, and provides an output voltage of 19Vdc or 24Vdc.
Quick Quote
Pilz PILZ-772102 is a communications unit designed for Ethernet POWERLINK V2 integration, featuring a controlled node device type with galvanic isolation for enhanced operational integrity between the fieldbus and module voltage, ensuring functional insulation with a rated surge voltage of 500V. It is engineered for DIN rail mounting, compatible with a 35mmx7.5mm horizontal rail, and operates within an ambient air temperature range of 0 to +60°C without forced convection and up to +55°C with it. The unit has a net height of 101.4 mm, supports a maximum rated current of 50mA from an external power supply, and offers connectivity through an RJ45 interface or screw or spring-loaded terminal connections accommodating 2 points per connection with a 9mm stripping length. As part of the communication module sub-range, it measures 22.5 mm in width, 110.4 mm in depth, and is housed in a green PC material with an IP20 degree of protection. The supply voltage ranges from 19.2 to 30Vdc, with a nominal 24Vdc and an additional 3.3Vdc supplied via the base unit. It supports wire cross-sections from 0.25 to 2.5mm2 for single-core flexible wires with screw connections and slightly different specifications for other wire types. The power consumption is rated at 1.2 W from an external power supply and 0.2 W from the supply via the base unit, with a maximum power dissipation/loss of 1.5 W. The unit is designed for storage in environments ranging from -25 to +70°C, features a rated insulation voltage of 30 V for potential isolation, and facilitates a transmission rate of 100MBit/s, with a current consumption of 60mA from the supply via the base module.
Quick Quote
Pilz PILZ-773104 is a safety controller designed as a configurable safety base unit or safe small controller. It features airgap creepage distances of 3mm between relay contacts and 5.5mm between relay contacts and other circuits. The unit offers potential isolation with protective separation, having a rated surge voltage of 2500V between SC output and system voltage, and 6000V between relay output and system voltage. It supports DIN rail mounting (35mmx7.5mm; horizontal) and operates within an ambient air temperature range of 0 to +60°C without forced convection and up to +55°C. The controller has a net height of 94mm, a rated current of 6A for both 24Vdc (DC-1) and 240Vac (AC-1), and lower ratings for other specific conditions. Connection types include plug-in/detachable screw or spring-loaded terminals with specified stripping lengths. It falls under the base unit sub-range, measures 27mm in width, and offers an IP20 degree of protection. The supply voltage requirement is 20.4-28.8Vdc, with a nominal 24Vdc. The housing is made of PPO and ABS materials. It supports a maximum cable length of 1000m per input and 40km overall for test pulse output, with a net width of 135mm. Communication is facilitated via RS-232 protocol. The controller accommodates various cross-sections for wiring, has a power consumption of 192W under load and 8W at no load, and a net depth of 121mm. It can be stored in temperatures ranging from -25 to +70°C. The device includes multiple digital outputs for safety, auxiliary, and relay functions, along with 20 safety inputs. It features short-circuit proof protection and potential isolation, with specific response times for different functions. The rated impulse voltage is 6kV, with a rated insulation voltage of 250V. Current consumption is specified at 6A, with detailed time delays for switch-off, switch-on, supply interruption, input delay, and input pulse suppression, alongside processing times for cycle and self-test durations.
Quick Quote
Pilz PILZ-773105 is a safety controller designed as a configurable safety base unit or safe small controller. It features airgap creepage distances of 3mm between relay contacts and 5.5mm between relay contacts and other circuits. The unit supports 2 x Ethernet for communication and offers potential isolation with protective separation, rated at 2500V between SC output and system voltage, and 6000V between relay output and system voltage. It is designed for DIN rail mounting (35mmx7.5mm; horizontal) and can operate in ambient air temperatures ranging from -25 to +60°C. The net height of the unit is 94mm, and it comes in a coated version that is expandable. It has a rated current of 6A at 24Vdc (DC-1), 4A at 24Vdc (DC-1 when t>50°C), 6A at 240Vac (AC-1), 4A at 240Vac (AC-1 when t>50°C), 3A at 24Vdc (DC-13; 6 cycles/min), and 3A at 230Vac (AC-15), with a residual current of 0.5mA at "0" signal and 2A at signal level "1". Connection types include plug-in/detachable screw or spring-loaded terminals with specified stripping lengths. The base unit has dimensions of W27mm, a degree of protection of IP20, and a supply voltage range of 20.4-28.8Vdc (24Vdc nom.). It is constructed with a PPO bottom housing and ABS front housing, supports a maximum cable length of 1000m per input and 40km overall for test pulse output, and has a net width of 135mm. The communication protocol is Ethernet, and it accommodates various cross-sections for wiring. Power consumption is detailed for output external power supply, expansion modules, and no load conditions. The net depth is 121mm, and it can be stored in ambient air temperatures of -25 to +70°C. It features 4 x digital outputs for safety semiconductor outputs, 1 x digital output for standard auxiliary semiconductor output, 2 x digital outputs for safety relay output, 4 x digital outputs for test pulse outputs, and 1 x digital output for standard cascading. Protection functions include short-circuit proofing, potential isolation, and galvanic isolation. Response times, rated impulse voltage, rated insulation voltage, digital inputs, current consumption, time delays, and processing times are specified to ensure precise operation and integration into safety systems.
Quick Quote
Pilz PILZ-772100 is a configurable safety base unit designed for DIN rail mounting, compatible with 35mmx7.5mm and 27mm DIN rails. It features a safety controller with an Ethernet interface, including 2 RJ45 connectors, and supports an automatic IP address setting of 169.254.60.1. The unit operates within an ambient air temperature range of 0 to +60°C without forced convection and up to +55°C with it. The net dimensions are 101.4 mm in height, 45 mm in width, and 120.2 mm in depth. It is designed for expandability via USB memory and offers various connection types, including plug-in/detachable screw or spring-loaded terminals. The base unit, with an IP20 degree of protection, requires a supply voltage of 19.2-30Vdc, with a nominal 24Vdc, and is housed in a PC material. It supports a maximum cable length of 2000m for test pulse output and accommodates wire cross-sections ranging from 0.25 to 2.5mm2 for screw connections and 0.2 to 1.5mm2 for spring connections. The power consumption is 18.5 W under load and 3 W with no load, with a maximum power dissipation of 4.5 W. It features 4 digital outputs for test pulses, short-circuit protection, a response time of 0.5 s for simultaneity in the 2-hand circuit, and a processing time of 30 ms, with a maximum duration OFF time during self-test of 4 ms. The communication protocol is Ethernet, supporting speeds of 10MBit/s and 100MBit/s, and the ambient air temperature for storage ranges from -25 to +70°C.
Quick Quote
Pilz PILZ-784193 is a safety relay designed for single or dual-channel operation with capabilities for safety gate monitoring, instantaneous E-STOP monitoring, limit switch monitoring, and light beam device monitoring for both type 2 (with or without test pulse) and type 4. It supports monitored manual reset and start-up testing with AND input and OR input, including a self-test feature. This part is suitable for DIN rail mounting and operates within an ambient air temperature range of -10 to +55 °C. It has a net height of 101 mm, a rated current for safety output contacts of 6A at 24Vdc (DC-1), 6A at 240Vac (AC-1), 4A at 24Vdc (DC-13), and 3A at 230Vac (AC-15). Connection is facilitated through plug-in/detachable spring terminal connections. The PILZ-784193, part of the PNOZ e6.1p sub-range, measures 45mm in width and 121mm in depth, with a degree of protection rated at IP40. It operates on a supply voltage of 19.2-30Vdc (24Vdc nominal) and is constructed with a PPO housing and an ABS front housing. The operating modes include single-channel operation with input wiring in accordance with EN 60204, dual-channel operation with or without detection of shorts between the pushbutton contacts, automatic start, and monitored start. It features 4 x instantaneous safety outputs, 2 x instantaneous safety outputs (semiconductor outputs), 1 x instantaneous auxiliary output (semiconductor output), and 2 x test pulse outputs. Protection functions include 2 operating modes with or without detection of shorts across contacts. Digital inputs comprise 1 x digital input, 2 x logic inputs, 1 x feedback input, 1 x start input, and 1 x self-monitoring input.
Quick Quote
Pilz PILZ-784190 is a safety relay designed for single or dual-channel operation with capabilities for safety gate monitoring, instantaneous E-STOP monitoring, limit switch monitoring, and light beam device monitoring type 2 (with or without test pulse). It features a monitored manual reset, start-up testing with AND input and OR input, and a self-test function. This part is suitable for DIN rail mounting and operates within an ambient air temperature range of -10 to +55°C. It has a net height of 101 mm, a rated current of 1.5A, and utilizes spring terminal connections. The PILZ-784190 belongs to the PNOZ e5.13p sub-range, measures 22.5mm in width, and has a net depth of 121 mm. It offers a degree of protection of IP40 and requires a supply voltage of 19.2-30Vdc (24Vdc nominal). The housing is made of PPO with an ABS front, ensuring compatibility with evaluation devices for safety sensors. Its operating mode includes dual-channel operation with a redundant input circuit, detection of earth faults in the input and start circuits, automatic start, and monitored start. The relay can increase the number of available contacts by connecting to contact expansion modules or external contactors/relays. It features 2 x instantaneous safety outputs and 2 x instantaneous auxiliary outputs, both semiconductor outputs (2SO), along with 1 x test pulse output. The protection functions include 2 operating modes (with or without detection of shorts across contacts), and it has digital inputs for enhanced functionality, including a digital input, a logic input, a feedback input, a start input, and a self-monitoring input.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
PILZ-772010 Pilz PILZ-772010 is a communications unit designed as an expansion/communication module with Ethernet POWERLINK V2 fieldbus interface, functioning as a controlled node. It features potential isolation between the fieldbus and module voltage with functional insulation and a rated surge voltage of 500V. This unit is suitable for DIN rail mounting, specifically on a 35mmx7.5mm horizontal rail, and operates within an ambient air temperature range of 0 to +60°C without forced convection and up to +55°C with it. The unit has a net height of 100 mm, a width of 22.5 mm, and a depth of 110.4 mm, and it connects via an RJ45 connector plug-in/detachable screw or spring-loaded terminals, supporting 2 points per spring-loaded connection with a 9mm stripping length. It belongs to the communication module sub-range, encased in a PC housing, and offers an IP20 degree of protection. The supply voltage ranges from 19.2 to 30Vdc, with a nominal 24Vdc, and an additional 3.23-3.37Vdc (3.3Vdc nominal) for module supply via the base unit. It supports a cross-section of 0.25 to 2.5mm2 for various connection types and consumes 1.2W power from the supply via the base unit, with an additional 0.2W for the module supply. The unit's power dissipation/losses are a maximum of 1.5W, operates with a speed of 100MBit/s for Ethernet POWERLINK V2, and has a current consumption of 60mA from the supply via the base module. It features a time delay of 20ms for supply interruption before de-energization and is designed for storage in ambient air temperatures ranging from -25 to +70°C. The unit includes protection functions such as galvanic isolation and potential isolation, with a rated insulation voltage (Ui) of 30 V. | Pilz | Quick Quote | |||
PILZ-773120 Pilz PILZ-773120 is a configurable safety base unit designed for DIN rail mounting, specifically on a 35mmx7.5mm horizontal rail. It operates within an ambient air temperature range of 0 to +60°C without forced convection and up to +55°C with forced convection off. This safety controller features an airgap creepage of 3mm between relay contacts and 5.5mm between relay contacts and other circuits. It offers potential isolation with protective separation, rated at 2500V between SC output and system voltage, and 6000V between relay output and system voltage. The unit is expandable for furnace/burner functions and supports a rated current of 6A for both 24Vdc (DC-1) and 240Vac (AC-1), with specific ratings for other operational modes. Connection options include plug-in/detachable screw or spring-loaded terminals, accommodating various wire sizes and types. The base unit has dimensions of 27mm in width, 94mm in height, and 121mm in depth, with a degree of protection rated at IP20. It requires a supply voltage of 20.4-28.8Vdc (24Vdc nominal) and is constructed from PPO and ABS materials. The PILZ-773120 supports RS-232 communication protocol, has a power consumption profile for different operational states, and offers multiple digital inputs and outputs with specific safety and standard configurations. It includes protection functions such as short-circuit proofing, potential and galvanic isolation, and features a range of response times for various operational parameters. | Pilz | Quick Quote | |||
PILZ-773125 Pilz PILZ-773125 is a safety controller designed as a configurable safety base unit or safe small controller. It features airgap creepage distances of 3mm between relay contacts and 5.5mm between relay contacts and other circuits. The unit supports 2 x Ethernet for communication and offers potential isolation with protective separation, having a rated surge voltage of 2500V between SC output and system voltage, and 6000V between relay output and system voltage. It is designed for DIN rail mounting, specifically on a 35mmx7.5mm horizontal rail, and operates within an ambient air temperature range of 0 to +60°C without forced convection and up to +55°C with forced convection off. The net height of the unit is 94mm, and it is expandable for furnace/burner function applications. The rated current specifications include 6A at 24Vdc (DC-1), 6A at 240Vac (AC-1), among others, with connection types accommodating plug-in/detachable screw or spring-loaded terminals. As part of the base unit sub-range, it measures 27mm in width and offers an IP20 degree of protection. The supply voltage requirement is 20.4-28.8Vdc (24Vdc nominal), constructed from PPO bottom housing and ABS front housing materials. It supports a maximum cable length of 1000m per input and 40km overall for test pulse output, with a net width of 135mm. Communication is facilitated via Ethernet, and it accepts various cross-sections for wiring. Power consumption varies with output external power supply up to 192W, with lower consumption for expansion modules and no load conditions. The net depth is 121mm, and it can be stored in temperatures ranging from -25 to +70°C. It features 4 x digital outputs for safety semiconductor outputs, additional outputs for standard auxiliary, safety relay, test pulse, and standard cascading functions. Protection functions include short-circuit proofing, potential isolation, and galvanic isolation. Response times range from 3s for simultaneity channel max to 0.5s for 2-hand circuit simultaneity, with a rated impulse voltage of 6kV and rated insulation voltage of 250V. It supports 20 x safety inputs, with a current consumption of 6A for blow-out fuse or circuit breaker. Time delays and processing times are specified for various operational parameters, ensuring precise control and safety measures. | Pilz | Quick Quote | |||
PILZ-773113 Pilz PILZ-773113 is a power supply unit designed for DIN rail mounting, specifically for horizontal placement on top of a hat rail. It operates within an ambient air temperature range of -10 to +55 °C and features screw terminal connections. This unit has a net height of 94 mm, a width of 45 mm, and a depth of 121 mm, encased in an ABS housing. It supports a supply voltage range of 100Vac-240Vac (including 120Vac, 208Vac, 220Vac, 230Vac) and 100Vdc-240Vdc (including 110Vdc, 120Vdc, 220Vdc nom.), with a rated current of 0.62A to 0.79A. The PILZ-773113, part of the PNOZ pps1p sub-range, offers a degree of protection rated at IP20. It has a power consumption of 30 VA, a rated power of 15W, and provides an output voltage of 19Vdc or 24Vdc. | Pilz | Quick Quote | |||
PILZ-772102 Pilz PILZ-772102 is a communications unit designed for Ethernet POWERLINK V2 integration, featuring a controlled node device type with galvanic isolation for enhanced operational integrity between the fieldbus and module voltage, ensuring functional insulation with a rated surge voltage of 500V. It is engineered for DIN rail mounting, compatible with a 35mmx7.5mm horizontal rail, and operates within an ambient air temperature range of 0 to +60°C without forced convection and up to +55°C with it. The unit has a net height of 101.4 mm, supports a maximum rated current of 50mA from an external power supply, and offers connectivity through an RJ45 interface or screw or spring-loaded terminal connections accommodating 2 points per connection with a 9mm stripping length. As part of the communication module sub-range, it measures 22.5 mm in width, 110.4 mm in depth, and is housed in a green PC material with an IP20 degree of protection. The supply voltage ranges from 19.2 to 30Vdc, with a nominal 24Vdc and an additional 3.3Vdc supplied via the base unit. It supports wire cross-sections from 0.25 to 2.5mm2 for single-core flexible wires with screw connections and slightly different specifications for other wire types. The power consumption is rated at 1.2 W from an external power supply and 0.2 W from the supply via the base unit, with a maximum power dissipation/loss of 1.5 W. The unit is designed for storage in environments ranging from -25 to +70°C, features a rated insulation voltage of 30 V for potential isolation, and facilitates a transmission rate of 100MBit/s, with a current consumption of 60mA from the supply via the base module. | Pilz | Quick Quote | |||
PILZ-773104 Pilz PILZ-773104 is a safety controller designed as a configurable safety base unit or safe small controller. It features airgap creepage distances of 3mm between relay contacts and 5.5mm between relay contacts and other circuits. The unit offers potential isolation with protective separation, having a rated surge voltage of 2500V between SC output and system voltage, and 6000V between relay output and system voltage. It supports DIN rail mounting (35mmx7.5mm; horizontal) and operates within an ambient air temperature range of 0 to +60°C without forced convection and up to +55°C. The controller has a net height of 94mm, a rated current of 6A for both 24Vdc (DC-1) and 240Vac (AC-1), and lower ratings for other specific conditions. Connection types include plug-in/detachable screw or spring-loaded terminals with specified stripping lengths. It falls under the base unit sub-range, measures 27mm in width, and offers an IP20 degree of protection. The supply voltage requirement is 20.4-28.8Vdc, with a nominal 24Vdc. The housing is made of PPO and ABS materials. It supports a maximum cable length of 1000m per input and 40km overall for test pulse output, with a net width of 135mm. Communication is facilitated via RS-232 protocol. The controller accommodates various cross-sections for wiring, has a power consumption of 192W under load and 8W at no load, and a net depth of 121mm. It can be stored in temperatures ranging from -25 to +70°C. The device includes multiple digital outputs for safety, auxiliary, and relay functions, along with 20 safety inputs. It features short-circuit proof protection and potential isolation, with specific response times for different functions. The rated impulse voltage is 6kV, with a rated insulation voltage of 250V. Current consumption is specified at 6A, with detailed time delays for switch-off, switch-on, supply interruption, input delay, and input pulse suppression, alongside processing times for cycle and self-test durations. | Pilz | Quick Quote | |||
PILZ-773105 Pilz PILZ-773105 is a safety controller designed as a configurable safety base unit or safe small controller. It features airgap creepage distances of 3mm between relay contacts and 5.5mm between relay contacts and other circuits. The unit supports 2 x Ethernet for communication and offers potential isolation with protective separation, rated at 2500V between SC output and system voltage, and 6000V between relay output and system voltage. It is designed for DIN rail mounting (35mmx7.5mm; horizontal) and can operate in ambient air temperatures ranging from -25 to +60°C. The net height of the unit is 94mm, and it comes in a coated version that is expandable. It has a rated current of 6A at 24Vdc (DC-1), 4A at 24Vdc (DC-1 when t>50°C), 6A at 240Vac (AC-1), 4A at 240Vac (AC-1 when t>50°C), 3A at 24Vdc (DC-13; 6 cycles/min), and 3A at 230Vac (AC-15), with a residual current of 0.5mA at "0" signal and 2A at signal level "1". Connection types include plug-in/detachable screw or spring-loaded terminals with specified stripping lengths. The base unit has dimensions of W27mm, a degree of protection of IP20, and a supply voltage range of 20.4-28.8Vdc (24Vdc nom.). It is constructed with a PPO bottom housing and ABS front housing, supports a maximum cable length of 1000m per input and 40km overall for test pulse output, and has a net width of 135mm. The communication protocol is Ethernet, and it accommodates various cross-sections for wiring. Power consumption is detailed for output external power supply, expansion modules, and no load conditions. The net depth is 121mm, and it can be stored in ambient air temperatures of -25 to +70°C. It features 4 x digital outputs for safety semiconductor outputs, 1 x digital output for standard auxiliary semiconductor output, 2 x digital outputs for safety relay output, 4 x digital outputs for test pulse outputs, and 1 x digital output for standard cascading. Protection functions include short-circuit proofing, potential isolation, and galvanic isolation. Response times, rated impulse voltage, rated insulation voltage, digital inputs, current consumption, time delays, and processing times are specified to ensure precise operation and integration into safety systems. | Pilz | Quick Quote | |||
PILZ-772100 Pilz PILZ-772100 is a configurable safety base unit designed for DIN rail mounting, compatible with 35mmx7.5mm and 27mm DIN rails. It features a safety controller with an Ethernet interface, including 2 RJ45 connectors, and supports an automatic IP address setting of 169.254.60.1. The unit operates within an ambient air temperature range of 0 to +60°C without forced convection and up to +55°C with it. The net dimensions are 101.4 mm in height, 45 mm in width, and 120.2 mm in depth. It is designed for expandability via USB memory and offers various connection types, including plug-in/detachable screw or spring-loaded terminals. The base unit, with an IP20 degree of protection, requires a supply voltage of 19.2-30Vdc, with a nominal 24Vdc, and is housed in a PC material. It supports a maximum cable length of 2000m for test pulse output and accommodates wire cross-sections ranging from 0.25 to 2.5mm2 for screw connections and 0.2 to 1.5mm2 for spring connections. The power consumption is 18.5 W under load and 3 W with no load, with a maximum power dissipation of 4.5 W. It features 4 digital outputs for test pulses, short-circuit protection, a response time of 0.5 s for simultaneity in the 2-hand circuit, and a processing time of 30 ms, with a maximum duration OFF time during self-test of 4 ms. The communication protocol is Ethernet, supporting speeds of 10MBit/s and 100MBit/s, and the ambient air temperature for storage ranges from -25 to +70°C. | Pilz | Quick Quote | |||
PILZ-784193 Pilz PILZ-784193 is a safety relay designed for single or dual-channel operation with capabilities for safety gate monitoring, instantaneous E-STOP monitoring, limit switch monitoring, and light beam device monitoring for both type 2 (with or without test pulse) and type 4. It supports monitored manual reset and start-up testing with AND input and OR input, including a self-test feature. This part is suitable for DIN rail mounting and operates within an ambient air temperature range of -10 to +55 °C. It has a net height of 101 mm, a rated current for safety output contacts of 6A at 24Vdc (DC-1), 6A at 240Vac (AC-1), 4A at 24Vdc (DC-13), and 3A at 230Vac (AC-15). Connection is facilitated through plug-in/detachable spring terminal connections. The PILZ-784193, part of the PNOZ e6.1p sub-range, measures 45mm in width and 121mm in depth, with a degree of protection rated at IP40. It operates on a supply voltage of 19.2-30Vdc (24Vdc nominal) and is constructed with a PPO housing and an ABS front housing. The operating modes include single-channel operation with input wiring in accordance with EN 60204, dual-channel operation with or without detection of shorts between the pushbutton contacts, automatic start, and monitored start. It features 4 x instantaneous safety outputs, 2 x instantaneous safety outputs (semiconductor outputs), 1 x instantaneous auxiliary output (semiconductor output), and 2 x test pulse outputs. Protection functions include 2 operating modes with or without detection of shorts across contacts. Digital inputs comprise 1 x digital input, 2 x logic inputs, 1 x feedback input, 1 x start input, and 1 x self-monitoring input. | Pilz | Quick Quote | |||
PILZ-784190 Pilz PILZ-784190 is a safety relay designed for single or dual-channel operation with capabilities for safety gate monitoring, instantaneous E-STOP monitoring, limit switch monitoring, and light beam device monitoring type 2 (with or without test pulse). It features a monitored manual reset, start-up testing with AND input and OR input, and a self-test function. This part is suitable for DIN rail mounting and operates within an ambient air temperature range of -10 to +55°C. It has a net height of 101 mm, a rated current of 1.5A, and utilizes spring terminal connections. The PILZ-784190 belongs to the PNOZ e5.13p sub-range, measures 22.5mm in width, and has a net depth of 121 mm. It offers a degree of protection of IP40 and requires a supply voltage of 19.2-30Vdc (24Vdc nominal). The housing is made of PPO with an ABS front, ensuring compatibility with evaluation devices for safety sensors. Its operating mode includes dual-channel operation with a redundant input circuit, detection of earth faults in the input and start circuits, automatic start, and monitored start. The relay can increase the number of available contacts by connecting to contact expansion modules or external contactors/relays. It features 2 x instantaneous safety outputs and 2 x instantaneous auxiliary outputs, both semiconductor outputs (2SO), along with 1 x test pulse output. The protection functions include 2 operating modes (with or without detection of shorts across contacts), and it has digital inputs for enhanced functionality, including a digital input, a logic input, a feedback input, a start input, and a self-monitoring input. | Pilz | Quick Quote |