Instruments for measuring and monitoring electricity are essential tools for maintaining the safety and efficiency of electrical systems. These include devices such as multimeters and megohmmeters, which are used to measure aspects like voltage, current, resistance, and insulation resistance. These tools are crucial for tasks like maintenance, troubleshooting, and meeting safety standards in a range of applications.

Found 67 products

METSECT5MC080 on Powermatic Associates
Schneider Electric

Schneider Electric METSECT5MC080 is a current transformer designed for DIN rail Busbar mounting without sealing. It operates within an ambient air temperature range of -25 to +60°C. This transformer is part of the sub-range dedicated to current transformation, accommodating bars with maximum cross-sections of 10x40mm, 20x32mm, and 25x25mm. It is designed to handle a primary current of 800 A and transforms it into a secondary current of 5 A. The maximum cable outer diameter that can be used with this transformer is 32 mm.

Quick Quote

METSECT5DD125 on Powermatic Associates
Schneider Electric

Schneider Electric METSECT5DD125 is a current transformer designed for busbar mounting and features sealing functionality. It operates within an ambient air temperature range of -25 to +60°C. This transformer is part of the sub-range named Current Transformer and accommodates a maximum cross-section of bars measuring 34x84mm. It is specified with a primary current of 1250 A and a secondary current of 5 A.

Quick Quote

BCPMSCB30S on Powermatic Associates
Schneider Electric

Schneider Electric BCPMSCB30S, part of the BCPM range, is designed for clip-on (bracket) mounting and utilizes the Modbus RS485 communication protocol. It operates within a network frequency of 50-60 Hz and offers a sampling rate of 12,800 Hz at 50Hz and 15,360 Hz at 60Hz. The measurement accuracy for current and voltage is 0.5%, and for power/energy, it is 1%. Its measurement functions include power factor (total/per phase; mains only), frequency, voltage, current, voltage sag and swell detection, active energy (mains only), active power (total/per phase; mains only), demand total active power (present; max values - mains only), and detection of under/overvoltage.

Quick Quote

BCPMSCBY63S on Powermatic Associates
Schneider Electric

Schneider Electric BCPMSCBY63S, part of the BCPM range, is designed for clip-on (bracket) mounting and utilizes the Modbus RS485 communication protocol. It operates within a network frequency of 50-60 Hz and offers a sampling rate of 12,800 Hz at 50Hz and 15,360 Hz at 60Hz. This part boasts a measurement accuracy of 0.5% for both current and voltage, and 1% for power and energy. Its measurement functions include power factor (total/per phase; mains only), frequency, voltage, current, voltage sag and swell detection, active energy (mains only), active power (total/per phase; mains only), and demand total active power (present; max values - mains only), along with detection of under/overvoltage.

Quick Quote

EBX210 on Powermatic Associates
Schneider Electric

Schneider Electric EBX210 is a data logger designed for DIN rail mounting, falling under the ComX sub-range. It features 128MB RAM and offers a variety of connectivity options including 1 Ethernet (PoE), 1 Ethernet DHCP, and 2 x RS-485 ports. Additionally, it is equipped with 6 Digital Inputs (DI) and 2 Analog Inputs (AI). The EBX210 is UL compliant, ensuring adherence to relevant safety standards.

Quick Quote

METSECT5MA030 on Powermatic Associates
Schneider Electric

Schneider Electric METSECT5MA030 is a current transformer designed for DIN rail Busbar mounting without sealing. It operates within an ambient air temperature range of -25 to +60°C. This transformer accommodates bars with a maximum cross-section of 10x32mm or 15x25mm and cables with a maximum outer diameter of 27mm. It is engineered to transform a primary current of 300 A into a secondary current of 5 A.

Quick Quote

LUTC0301 on Powermatic Associates
Schneider Electric

Schneider Electric LUTC0301 is a current transformer (CT) from the Ultra sub-range, designed to transform a primary current of 30 A into a secondary current of 1 A.

Quick Quote

METSECT5DC250 on Powermatic Associates
Schneider Electric

Schneider Electric METSECT5DC250 is a current transformer designed for busbar mounting and features sealing functionality. It operates within an ambient air temperature range of -25 to +60°C. This transformer is part of the sub-range dedicated to current transformers and accommodates a maximum bar cross-section of 52x27mm. It is designed to transform a primary current of 2500 A into a secondary current of 5 A.

Quick Quote

METSECT5MA015 on Powermatic Associates
Schneider Electric

Schneider Electric METSECT5MA015 is a current transformer designed for DIN rail Busbar mounting without sealing. It operates within an ambient air temperature range of -25 to +60°C. This transformer accommodates bars with a maximum cross-section of 10x32mm or 15x25mm and cables with a maximum outer diameter of 27mm. It is engineered to transform a primary current of 150 A into a secondary current of 5 A.

Quick Quote

METSECT5DC400 on Powermatic Associates
Schneider Electric

Schneider Electric METSECT5DC400 is a current transformer designed for busbar mounting with a sealing function. It operates within an ambient air temperature range of -25 to +60°C. This transformer accommodates a maximum bar cross-section of 34x27mm and is engineered to transform a primary current of 4000 A into a secondary current of 5 A.

Quick Quote

ItemManufacturerPriceStockDelivery
METSECT5MC080 on Powermatic Associates

METSECT5MC080

Schneider Electric METSECT5MC080 is a current transformer designed for DIN rail Busbar mounting without sealing. It operates within an ambient air temperature range of -25 to +60°C. This transformer is part of the sub-range dedicated to current transformation, accommodating bars with maximum cross-sections of 10x40mm, 20x32mm, and 25x25mm. It is designed to handle a primary current of 800 A and transforms it into a secondary current of 5 A. The maximum cable outer diameter that can be used with this transformer is 32 mm.

Schneider Electric

Quick Quote

METSECT5DD125 on Powermatic Associates

METSECT5DD125

Schneider Electric METSECT5DD125 is a current transformer designed for busbar mounting and features sealing functionality. It operates within an ambient air temperature range of -25 to +60°C. This transformer is part of the sub-range named Current Transformer and accommodates a maximum cross-section of bars measuring 34x84mm. It is specified with a primary current of 1250 A and a secondary current of 5 A.

Schneider Electric

Quick Quote

BCPMSCB30S on Powermatic Associates

BCPMSCB30S

Schneider Electric BCPMSCB30S, part of the BCPM range, is designed for clip-on (bracket) mounting and utilizes the Modbus RS485 communication protocol. It operates within a network frequency of 50-60 Hz and offers a sampling rate of 12,800 Hz at 50Hz and 15,360 Hz at 60Hz. The measurement accuracy for current and voltage is 0.5%, and for power/energy, it is 1%. Its measurement functions include power factor (total/per phase; mains only), frequency, voltage, current, voltage sag and swell detection, active energy (mains only), active power (total/per phase; mains only), demand total active power (present; max values - mains only), and detection of under/overvoltage.

Schneider Electric

Quick Quote

BCPMSCBY63S on Powermatic Associates

BCPMSCBY63S

Schneider Electric BCPMSCBY63S, part of the BCPM range, is designed for clip-on (bracket) mounting and utilizes the Modbus RS485 communication protocol. It operates within a network frequency of 50-60 Hz and offers a sampling rate of 12,800 Hz at 50Hz and 15,360 Hz at 60Hz. This part boasts a measurement accuracy of 0.5% for both current and voltage, and 1% for power and energy. Its measurement functions include power factor (total/per phase; mains only), frequency, voltage, current, voltage sag and swell detection, active energy (mains only), active power (total/per phase; mains only), and demand total active power (present; max values - mains only), along with detection of under/overvoltage.

Schneider Electric

Quick Quote

EBX210 on Powermatic Associates

EBX210

Schneider Electric EBX210 is a data logger designed for DIN rail mounting, falling under the ComX sub-range. It features 128MB RAM and offers a variety of connectivity options including 1 Ethernet (PoE), 1 Ethernet DHCP, and 2 x RS-485 ports. Additionally, it is equipped with 6 Digital Inputs (DI) and 2 Analog Inputs (AI). The EBX210 is UL compliant, ensuring adherence to relevant safety standards.

Schneider Electric

Quick Quote

METSECT5MA030 on Powermatic Associates

METSECT5MA030

Schneider Electric METSECT5MA030 is a current transformer designed for DIN rail Busbar mounting without sealing. It operates within an ambient air temperature range of -25 to +60°C. This transformer accommodates bars with a maximum cross-section of 10x32mm or 15x25mm and cables with a maximum outer diameter of 27mm. It is engineered to transform a primary current of 300 A into a secondary current of 5 A.

Schneider Electric

Quick Quote

LUTC0301 on Powermatic Associates

LUTC0301

Schneider Electric LUTC0301 is a current transformer (CT) from the Ultra sub-range, designed to transform a primary current of 30 A into a secondary current of 1 A.

Schneider Electric

Quick Quote

METSECT5DC250 on Powermatic Associates

METSECT5DC250

Schneider Electric METSECT5DC250 is a current transformer designed for busbar mounting and features sealing functionality. It operates within an ambient air temperature range of -25 to +60°C. This transformer is part of the sub-range dedicated to current transformers and accommodates a maximum bar cross-section of 52x27mm. It is designed to transform a primary current of 2500 A into a secondary current of 5 A.

Schneider Electric

Quick Quote

METSECT5MA015 on Powermatic Associates

METSECT5MA015

Schneider Electric METSECT5MA015 is a current transformer designed for DIN rail Busbar mounting without sealing. It operates within an ambient air temperature range of -25 to +60°C. This transformer accommodates bars with a maximum cross-section of 10x32mm or 15x25mm and cables with a maximum outer diameter of 27mm. It is engineered to transform a primary current of 150 A into a secondary current of 5 A.

Schneider Electric

Quick Quote

METSECT5DC400 on Powermatic Associates

METSECT5DC400

Schneider Electric METSECT5DC400 is a current transformer designed for busbar mounting with a sealing function. It operates within an ambient air temperature range of -25 to +60°C. This transformer accommodates a maximum bar cross-section of 34x27mm and is engineered to transform a primary current of 4000 A into a secondary current of 5 A.

Schneider Electric

Quick Quote

Electrical Measuring & Monitoring Instruments

General Guide & Overview

Electrical measuring instruments play a crucial role in ensuring the safety and efficiency of electrical systems. From measuring voltage and current to diagnosing electrical issues, these instruments provide valuable information for maintenance and troubleshooting purposes.

There are various types of electrical measuring instruments available, each designed for specific applications. Whether you are a professional electrician, an engineer, or a DIY enthusiast, understanding these instruments is essential when working with electricity.

In this guide, we will provide an overview of different electrical measuring instruments and their functions. From multimeters to megohmmeters, we will explore the types of instruments used in electrical testing and the safety precautions associated with them.

By the end of this guide, you will have a better understanding of the various tools and devices available for measuring and monitoring electrical parameters. Whether you are a beginner or an experienced professional, this guide will serve as a valuable resource in your electrical testing journey.

Multimeter

A multimeter, also known as a Volt-Ohm meter (VOM), is a handheld device that combines multiple measurement functions, including voltage, current, resistance, and frequency, into a single unit.

The multimeter is a versatile device that can be used to test and troubleshoot electronic equipment, motor controls, domestic appliances, power supplies, and wiring systems. Its portable and compact design makes it convenient to carry and use in different locations or on the go.

With a multimeter, you can accurately measure voltage to check if electrical circuits are delivering the expected power. It allows you to determine the current flowing through a circuit, helping you analyze the performance and efficiency of electrical devices. The resistance measurement function helps identify faulty or damaged components in a circuit, allowing for timely repairs.

In addition, a multimeter can measure frequency, which is essential for diagnosing issues in electrical systems that rely on specific frequency ranges, such as motor controls and power supplies.

With its ability to measure voltage, current, resistance, and frequency, this handheld device helps you ensure the proper functioning of electronic equipment, motor controls, domestic appliances, power supplies, and wiring systems, making it an essential addition to any toolkit.

Megohmmeter

A megohmmeter, commonly known as a "megger," is a specialized type of ohmmeter used to measure the electrical resistance of insulators. It plays a crucial role in ensuring the safety and efficiency of electrical systems. Megohmmeters are designed to accurately measure resistance values ranging from several megohms to several million megohms, allowing technicians to evaluate the insulation properties of various equipment and components.

Megohmmeters are extensively used in industries such as power generation, transmission, and distribution. They are particularly valuable for assessing the insulation integrity of critical equipment like circuit breakers, transformers, switchgear, and cables. By measuring the resistance, technicians can identify potential issues like degraded insulation, moisture ingress, or other faults that may compromise the safety and functionality of electrical systems.

Unlike standard ohmmeters, which measure low resistance values, megohmmeters utilize high voltage levels to test the insulation properties of materials. This high voltage helps to identify leaks or weak spots in the insulation and ensures that the materials meet the required safety standards. Megohmmeters provide valuable insights into the electrical health of different components, allowing technicians to diagnose problems and take preventive actions.

When using a megohmmeter, it is important to follow safety precautions and use the appropriate personal protective equipment (PPE) to protect against potential electrical hazards. Technicians should carefully follow the manufacturer's instructions and ensure that the equipment is properly calibrated and maintained for accurate measurements. By utilizing megohmmeters in regular testing and maintenance procedures, electrical systems can operate at their optimum level, ensuring reliable performance and reducing the risk of malfunctions and costly downtime.

Safety Precautions and Conclusion

Before using a multimeter or any electrical testing equipment, it is crucial to understand the necessary safety precautions and guidelines. This ensures not only the accuracy of the measurements but also the personal safety of the operator.

To begin, it is essential to check the multimeter's electrical parameters, such as voltage range and current capacity, to ensure they are suitable for the intended application. Additionally, understanding the multimeter's Category (CAT) rating is crucial in assessing its safety level for various electrical environments. The CAT rating indicates the maximum voltage and current the multimeter can safely withstand.

Furthermore, performing a visual inspection of the multimeter before use is vital. One must check for any physical damage, loose connections, or worn-out leads or probes. If any defects are identified, the multimeter should be repaired or replaced to avoid potential hazards.

When working with electricity, personal protective equipment (PPE) is essential. This may include insulating gloves, safety glasses, and non-conductive footwear. Using PPE not only protects against electrical shock but also ensures overall safety in case of accidents.

In conclusion, adhering to proper safety precautions and guidelines when using multimeters or any electrical testing equipment is of utmost importance. By considering multimeter CAT ratings, performing visual inspections, and wearing appropriate PPE, the operator can minimize the risk of electrical hazards. These preventive measures ensure the accurate and safe functioning of the multimeter, allowing for reliable measurements and effective troubleshooting in various electrical systems. Remember, safety should always be the top priority when working with electricity.

FAQ

Electrical testing involves applying voltage or current to a circuit and comparing the measured value to an expected result. It is important because it helps verify the calculations within a circuit and diagnose electrical issues.

Some commonly used electrical measuring instruments include multimeters, megohmmeters, low-resistance ohmmeters, hipotential test sets, high current test sets, secondary test sets, relay test sets, power factor test sets, and winding resistance test sets.

A multimeter, also known as a Volt-Ohm meter (VOM), is a handheld device that combines multiple measurement functions, such as voltage, current, resistance, and frequency, into a single unit. It is primarily used to diagnose electrical issues in a wide range of industrial and household devices.

A megohmmeter, commonly known as a "megger," is a specialized type of ohmmeter used to measure the electrical resistance of insulators. It is frequently used to measure the insulation of various types of equipment, including circuit breakers, transformers, switchgear, and cables.

Before using any electrical testing equipment, it is important to understand the electrical parameters and safety precautions associated with them. This includes checking for appropriate CAT ratings, understanding the IP codes for dust and water resistance, and visually inspecting the meter for any physical damage. It is also crucial to take proper safety measures when working with electricity, such as using personal protective equipment (PPE) and following specific guidelines to prevent electrical hazards.