Isolating transducer, 1-channel, , Splitter function, Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, ATEX, IECEx, cFM, NEPSI, INMETRO, Kosha, TR CU EAC CMI, TS, Installation in zone 2, SIL 2
Quick Quote
Analog Signal Isolator, 1-channel, , Input circuit monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Temperature measuring amplifier, 1-channel, , Input circuits monitored for wire break and short circuit, Parameterized via PC, Complete galvanic isolation, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Analog signal isolator, 1-channel, , Transmission of normalized analog signals, Input circuit: 0/2…10 V or 0/4…20 mA, Output circuit: 2 × 0/4 0…20 mA, Complete galvanic isolation, Input reverse-polarity protected, TR CU
Quick Quote
Isolating switching amplifier, 1-channel, , Relay output (changeover), Alarm output (changeover), Switchable: Alarm output or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, KOSHA, TIIS, TR CU EAC, Installation in zone 2, SIL 2
Quick Quote
Potentiometer Amplifier, 2-channel, , Transmission of potentiometer signals from the Ex area, Potentiometer, nominal resistance: 0.8…100 kΩ, Output circuit: 0…10 V, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, TR CU, KOSHA, Installation in zone 2
Quick Quote
Isolating transducer, 1-channel, , Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, ATEX, IECEx, cFM, NEPSI, INMETRO, Kosha, TR CU EAC CMI, TS, Installation in zone 2, SIL 2
Quick Quote
Temperature measuring amplifier, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, cFM,cUL, NEPSI, INMETRO, Kosha, TR CU EAC CMI, Installation in zone 2, SIL 2
Quick Quote
Isolating transducer, 1-channel, , Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Temperature measuring amplifier, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX, IECEx, cFM,cUL, NEPSI, INMETRO, Kosha, TR CU EAC CMI, TS, Installation in zone 2, SIL 2
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
IMX12-AI01-1I-2IU-H0/24VDC Isolating transducer, 1-channel, , Splitter function, Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, ATEX, IECEx, cFM, NEPSI, INMETRO, Kosha, TR CU EAC CMI, TS, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IM12-AO01-1I-1I-HPR/24VDC Analog Signal Isolator, 1-channel, , Input circuit monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IM12-TI02-1TCURTDR-1I1R-CPR/24VDC Temperature measuring amplifier, 1-channel, , Input circuits monitored for wire break and short circuit, Parameterized via PC, Complete galvanic isolation, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IM31-12-I Analog signal isolator, 1-channel, , Transmission of normalized analog signals, Input circuit: 0/2…10 V or 0/4…20 mA, Output circuit: 2 × 0/4 0…20 mA, Complete galvanic isolation, Input reverse-polarity protected, TR CU | Turck | Quick Quote | |||
IMX12-DI03-1S-2R-SPR/24VDC/CC Isolating switching amplifier, 1-channel, , Relay output (changeover), Alarm output (changeover), Switchable: Alarm output or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, KOSHA, TIIS, TR CU EAC, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IM36-22EX-U Potentiometer Amplifier, 2-channel, , Transmission of potentiometer signals from the Ex area, Potentiometer, nominal resistance: 0.8…100 kΩ, Output circuit: 0…10 V, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, TR CU, KOSHA, Installation in zone 2 | Turck | Quick Quote | |||
IMX12-AI01-1I-1IU-HPR/24VDC/CC Isolating transducer, 1-channel, , Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, ATEX, IECEx, cFM, NEPSI, INMETRO, Kosha, TR CU EAC CMI, TS, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IMX12-TI01-2RTDR-2I-CPR/24VDC/CC Temperature measuring amplifier, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, cFM,cUL, NEPSI, INMETRO, Kosha, TR CU EAC CMI, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IM12-AI01-1I-1IU-H0/24VDC/CC Isolating transducer, 1-channel, , Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IMX12-TI02-2TCURTDR-2I-C0/24VDC/CC Temperature measuring amplifier, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX, IECEx, cFM,cUL, NEPSI, INMETRO, Kosha, TR CU EAC CMI, TS, Installation in zone 2, SIL 2 | Turck | Quick Quote |