Isolating transducer, 1-channel, , Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, ATEX, IECEx, cFM, NEPSI, INMETRO, Kosha, TR CU EAC CMI, TS, Installation in zone 2, SIL 2
Quick Quote
Isolating switching amplifier, 2-channel, , 2 transistor outputs (MOSFET), Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, CSA, TR CU, NEPSI, KOSHA, TIIS, CCOE, INMETRO, Installation in zone 2
Quick Quote
Analog Signal Isolator, 1-channel, , Input circuit monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Temperature measuring amplifier, 2-channel, , Input circuits monitored for wire break and short circuit, Parameterized via PC, Complete galvanic isolation, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Temperature measuring amplifier, 2-channel, , Input circuits monitored for wire break and short circuit, Parameterized via PC, Complete galvanic isolation, Removable spring type terminals, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Solenoid Driver, 1-channel, , Valve control module, 1-channel, Complete galvanic isolation, Input reverse-polarity protected, Protection class IP67, Connection with M12 male connectors, ATEX, C, FM, US, IECEx, Use in Zone 2/22
Quick Quote
Isolating switching amplifier, 1-channel, , Relay output (changeover), NAMUR Repeater, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, KOSHA, TIIS, TR CU EAC, Installation in zone 2, SIL 2
Quick Quote
Frequency Transducer/Pulse Counter, 1-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Removable spring type terminals, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Isolating transducer, 2-channel, , Power supply of 2-wire measuring transducers with HART communication as well as connection to active 2-wire and passive 3-wire transmitters, Input circuit: 0/4…20 mA, Output circuit: 0/4…20 mA, SIL 2, Removable terminal blocks, screwable, with 2 mm test box, Complete galvanic isolation, Input reverse-polarity protected, TR CU
Quick Quote
Isolating switching amplifier, 2-channel, , 2 relay outputs (complementary contact), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
IMX12-AI01-1I-1IU-H0/24VDC/CC Isolating transducer, 1-channel, , Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, ATEX, IECEx, cFM, NEPSI, INMETRO, Kosha, TR CU EAC CMI, TS, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IM1-22EX-MT Isolating switching amplifier, 2-channel, , 2 transistor outputs (MOSFET), Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, CSA, TR CU, NEPSI, KOSHA, TIIS, CCOE, INMETRO, Installation in zone 2 | Turck | Quick Quote | |||
IM12-AO01-1I-1I-H0/24VDC/CC Analog Signal Isolator, 1-channel, , Input circuit monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IM12-TI01-2RTDR-2I-CPR/24VDC/CC Temperature measuring amplifier, 2-channel, , Input circuits monitored for wire break and short circuit, Parameterized via PC, Complete galvanic isolation, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IM12-TI01-2RTDR-2I-C0/24VDC/CC Temperature measuring amplifier, 2-channel, , Input circuits monitored for wire break and short circuit, Parameterized via PC, Complete galvanic isolation, Removable spring type terminals, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IMC-DO-11EX/L Solenoid Driver, 1-channel, , Valve control module, 1-channel, Complete galvanic isolation, Input reverse-polarity protected, Protection class IP67, Connection with M12 male connectors, ATEX, C, FM, US, IECEx, Use in Zone 2/22 | Turck | Quick Quote | |||
IMX12-DI03-1S-1NAM1R-PR/24VDC Isolating switching amplifier, 1-channel, , Relay output (changeover), NAMUR Repeater, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, KOSHA, TIIS, TR CU EAC, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IM12-FI01-1SF-1I1R-C0/24VDC/CC Frequency Transducer/Pulse Counter, 1-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Removable spring type terminals, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IM33-22-HI/24VDC Isolating transducer, 2-channel, , Power supply of 2-wire measuring transducers with HART communication as well as connection to active 2-wire and passive 3-wire transmitters, Input circuit: 0/4…20 mA, Output circuit: 0/4…20 mA, SIL 2, Removable terminal blocks, screwable, with 2 mm test box, Complete galvanic isolation, Input reverse-polarity protected, TR CU | Turck | Quick Quote | |||
IM12-DI01-2S-2R-PR/24VDC Isolating switching amplifier, 2-channel, , 2 relay outputs (complementary contact), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote |