Isolating switching amplifier, 2-channel, , Adjustable output mode (NO/NC), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, ATEX, C, FM, US, TR CU
Quick Quote
Analog signal isolator, 2-channel, , Transmission of normalized analog signals from the Ex area to the non-Ex area, Input circuits: 0/2…10 V or 0/4…20 mA, Output circuits: 0/4…20 mA, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, NEPSI, KOSHA, Installation in zone 2
Quick Quote
Isolating transducer, 1-channel, , Power supply of 2-wire measuring transducers with HART communication as well as connection to active 2-wire and passive 3-wire transmitters, Input circuit: 0/4…20 mA, Output circuit: 0/4…20 mA, Removable terminal blocks, screwable, with 2 mm test socket, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, C, FM, US, TR CU, INMETRO, Installation in zone 2
Quick Quote
Temperature measuring amplifier, 1-channel, , Input for Pt100/ Ni100 resistors, thermocouples and millivolt signals in 2, 3 or 4-wire technology, Output circuit: 0/4…20 mA, Parameterized via PC (FDT / DTM), Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, C, FM, US, UL, TR CU, INMETRO, CCOE, NEPSI, KOSHA, Installation in zone 2
Quick Quote
Solenoid Driver, 1-channel, , Voltage input max. 30 VDC, Voltage outuput 15 VDC resp. 24 VDC, Output current ≤ 40 mA, Switching frequency ≤ 500 Hz, SIL3, Removable terminal blocks, Galvanic isolation between input circuits and output circuits, ATEX, IECEx, UL, C, FM, US, TR CU,NEPSI, INMETRO, Kosha, Installation in zone 2
Quick Quote
Isolating switching amplifier, 1-channel, , 2 transistor outputs, short-circuit proof, potential-free and reverse-polarity protected, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), SIL 2, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, CSA, TR CU, NEPSI, KOSHA, TIIS, CCOE, INMETRO, Installation in zone 2
Quick Quote
Analog signal isolator, 1-channel, , Transmission of normalized analog signals from the Ex area to the non-Ex area, Input circuit: 0/2…10 V or 0/4…20 mA, Output circuit: 0/4…20 mA, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, NEPSI, KOSHA, Installation in zone 2
Quick Quote
Analog signal isolator, 1-channel, , Transmission of normalized analog signals from the Ex area to the non-Ex area, Input circuit: 0/2…10 V or 0/4…20 mA, Output circuit: 2 x 0/4 0…20 mA, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, NEPSI, KOSHA, Installation in zone 2
Quick Quote
Isolating transducer, 1-channel, , Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, Male connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Temperature measuring amplifier, 2-channel, , Input circuits monitored for wire break and short circuit, Parameterized via PC, Complete galvanic isolation, Removable screw terminals, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
IM1-22EX-R/24VDC Isolating switching amplifier, 2-channel, , Adjustable output mode (NO/NC), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, ATEX, C, FM, US, TR CU | Turck | Quick Quote | |||
IM31-22EX-I Analog signal isolator, 2-channel, , Transmission of normalized analog signals from the Ex area to the non-Ex area, Input circuits: 0/2…10 V or 0/4…20 mA, Output circuits: 0/4…20 mA, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, NEPSI, KOSHA, Installation in zone 2 | Turck | Quick Quote | |||
IM33-11EX-HI Isolating transducer, 1-channel, , Power supply of 2-wire measuring transducers with HART communication as well as connection to active 2-wire and passive 3-wire transmitters, Input circuit: 0/4…20 mA, Output circuit: 0/4…20 mA, Removable terminal blocks, screwable, with 2 mm test socket, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, C, FM, US, TR CU, INMETRO, Installation in zone 2 | Turck | Quick Quote | |||
IM34-11EX-CI Temperature measuring amplifier, 1-channel, , Input for Pt100/ Ni100 resistors, thermocouples and millivolt signals in 2, 3 or 4-wire technology, Output circuit: 0/4…20 mA, Parameterized via PC (FDT / DTM), Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, C, FM, US, UL, TR CU, INMETRO, CCOE, NEPSI, KOSHA, Installation in zone 2 | Turck | Quick Quote | |||
IM72-11EX/L Solenoid Driver, 1-channel, , Voltage input max. 30 VDC, Voltage outuput 15 VDC resp. 24 VDC, Output current ≤ 40 mA, Switching frequency ≤ 500 Hz, SIL3, Removable terminal blocks, Galvanic isolation between input circuits and output circuits, ATEX, IECEx, UL, C, FM, US, TR CU,NEPSI, INMETRO, Kosha, Installation in zone 2 | Turck | Quick Quote | |||
IM1-12EX-T Isolating switching amplifier, 1-channel, , 2 transistor outputs, short-circuit proof, potential-free and reverse-polarity protected, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), SIL 2, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, CSA, TR CU, NEPSI, KOSHA, TIIS, CCOE, INMETRO, Installation in zone 2 | Turck | Quick Quote | |||
IM31-11EX-I Analog signal isolator, 1-channel, , Transmission of normalized analog signals from the Ex area to the non-Ex area, Input circuit: 0/2…10 V or 0/4…20 mA, Output circuit: 0/4…20 mA, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, NEPSI, KOSHA, Installation in zone 2 | Turck | Quick Quote | |||
IM31-12EX-I Analog signal isolator, 1-channel, , Transmission of normalized analog signals from the Ex area to the non-Ex area, Input circuit: 0/2…10 V or 0/4…20 mA, Output circuit: 2 x 0/4 0…20 mA, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, NEPSI, KOSHA, Installation in zone 2 | Turck | Quick Quote | |||
IM12-AI01-1I-1IU-HPR/24VDC/CC Isolating transducer, 1-channel, , Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, Male connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IM12-TI01-2RTDR-2I-C0/24VDC Temperature measuring amplifier, 2-channel, , Input circuits monitored for wire break and short circuit, Parameterized via PC, Complete galvanic isolation, Removable screw terminals, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote |