Isolating switching amplifier, 2-channel, , 2 transistor outputs (≤ 10kHz), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Isolating transducer, 1-channel, , Power supply of 2-wire measuring transducers, Input circuit: 0/4…20 mA, Passive output circuit: 0/4…20 mA, Galvanic separation of input circuits, output circuits and power supply, Complete galvanic isolation, Input reverse-polarity protected, Intrinsically safe input circuits EEx ia, Application area acc. to ATEX: II (1) GD
Quick Quote
Coupling Relay, 1-channel, , The inputs are not polarized, Input E1 activates both outputs simultaneously, NE load connection: SIL 3 Safety Function for NE (Normally Energized) load (de-energized in safe state) is available, ND load connection: SIL 3 Safety Function for ND (Normally De-Energized) load (energized in safe state) is available, Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX use in Zone 2, SIL 3
Quick Quote
Solenoid Driver, 2-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX, IECEx, cUL, cFM, INMETRO, NEPSI, Kosha, TR CU EAC, TIIS, Installation in zone 2, SIL 2
Quick Quote
Coupling Relay, 2-channel, , The inputs are not polarized, With input E1 and input E2, the associated output switches separately, NE load connection: SIL 3 Safety Function for NE (Normally Energized) load (de-energized in safe state) is available, ND load connection: SIL 3 Safety Function for ND (Normally De-Energized) load (energized in safe state) is available, The device is available in a two-channel design for SIL 2 applications, Complete galvanic isolation, Input reverse-polarity protected,
Quick Quote
Frequency Transducer/Pulse Counter, 1-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Removable screw terminals, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Isolating transducer, 2-channel, , Input circuits monitored for wire-break and short-circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, ATEX installation in zone 2, SIL 2
Quick Quote
Isolating transducer, 2-channel, , Input circuits monitored for wire-break and short-circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Frequency Transducer/Pulse Counter, 1-channel, Operating voltage 10…30 VDC, Input circuits monitored for wire break and short circuit, Parameterized via DIP/rotary coding switch, Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Installation in Zone 2, SIL 2
Quick Quote
Isolating switching amplifier, 1-channel, , Relay output (changeover), NAMUR Repeater, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break and short-circuit, Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, KOSHA, TIIS, TR CU EAC, Installation in zone 2, SIL 2
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
IM12-DI01-2S-2T-PR/24VDC Isolating switching amplifier, 2-channel, , 2 transistor outputs (≤ 10kHz), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
MK33-11EX0-PLI/24VDC Isolating transducer, 1-channel, , Power supply of 2-wire measuring transducers, Input circuit: 0/4…20 mA, Passive output circuit: 0/4…20 mA, Galvanic separation of input circuits, output circuits and power supply, Complete galvanic isolation, Input reverse-polarity protected, Intrinsically safe input circuits EEx ia, Application area acc. to ATEX: II (1) GD | Turck | Quick Quote | |||
IM12-CD01-2R-1U-0/L/CC Coupling Relay, 1-channel, , The inputs are not polarized, Input E1 activates both outputs simultaneously, NE load connection: SIL 3 Safety Function for NE (Normally Energized) load (de-energized in safe state) is available, ND load connection: SIL 3 Safety Function for ND (Normally De-Energized) load (energized in safe state) is available, Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX use in Zone 2, SIL 3 | Turck | Quick Quote | |||
IMX12-DO01-2U-2U-0/24VDC Solenoid Driver, 2-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX, IECEx, cUL, cFM, INMETRO, NEPSI, Kosha, TR CU EAC, TIIS, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IMX12-CD01-2R-2U-0/L Coupling Relay, 2-channel, , The inputs are not polarized, With input E1 and input E2, the associated output switches separately, NE load connection: SIL 3 Safety Function for NE (Normally Energized) load (de-energized in safe state) is available, ND load connection: SIL 3 Safety Function for ND (Normally De-Energized) load (energized in safe state) is available, The device is available in a two-channel design for SIL 2 applications, Complete galvanic isolation, Input reverse-polarity protected, | Turck | Quick Quote | |||
IM12-FI01-1SF-1I1R-C0/24VDC Frequency Transducer/Pulse Counter, 1-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Removable screw terminals, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IIM12-AI01-2I-2IU-H0/24VDC/CC Isolating transducer, 2-channel, , Input circuits monitored for wire-break and short-circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, ATEX installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IM12-AI01-2I-2IU-HPR/24VDC/CC Isolating transducer, 2-channel, , Input circuits monitored for wire-break and short-circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IM12-FI01-1SF-1R-0/24VDC Frequency Transducer/Pulse Counter, 1-channel, Operating voltage 10…30 VDC, Input circuits monitored for wire break and short circuit, Parameterized via DIP/rotary coding switch, Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Installation in Zone 2, SIL 2 | Turck | Quick Quote | |||
IMX12-DI03-1S-1NAM1R-0/24VDC Isolating switching amplifier, 1-channel, , Relay output (changeover), NAMUR Repeater, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break and short-circuit, Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, KOSHA, TIIS, TR CU EAC, Installation in zone 2, SIL 2 | Turck | Quick Quote |