Isolating switching amplifier, 2-channel, , 2 relay outputs (NO), Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), SIL 2, Complete galvanic isolation, Input reverse-polarity protected, TR CU
Quick Quote
Isolating transducer, 1-channel, , Power supply of 2-wire measuring transducers with HART communication as well as connection to active 2-wire and passive 3-wire transmitters, Input circuit: 0/4…20 mA, Output circuits: 0/4…20 mA, SIL2, Removable terminal blocks, screwable, with 2 mm test box, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, CCEO, Kosha, Installation in zone 2
Quick Quote
Frequency Transducer/Pulse Counter, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Removable screw terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Isolating switching amplifier, 2-channel, , 2 transistor outputs (≤ 10kHz), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, Kosha, TIIS, TR CU EAC, DNV, GL, Installation in zone 2, SIL 2
Quick Quote
Isolating switching amplifier, 2-channel, , Two transistor outputs (push-pull), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Analog Signal Isolator, 1-channel, , Intelligent actuators supplied via HART communication interface, Input circuit: 0/4…20 mA, Output circuit: 0/4…20 mA, intrinsically safe, Universal operating voltage, Complete galvanic isolation, Input reverse-polarity protected, ATEX, TR CU, NEPSI, Installation in zone 2
Quick Quote
Isolating transducer, 1-channel, , Isolating transducer, 1-channel, Output circuit: 0/4…20 mA, Complete galvanic isolation, Input reverse-polarity protected, Protection class IP67, Connection with M12 male connectors, ATEX, C, FM, US, IECEx, Use in Zone 2/22
Quick Quote
Isolating transducer, 1-channel, , Splitter function, Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Relay coupler, 2-channel, , Relay coupler for switching of intrinsically safe and current limited circuits, High-quality reed relays with rhodium contacts, Switching frequency up to 50 Hz, Galvanic isolation between input and output circuits, ATEX, TR CU, Installation in zone 2
Quick Quote
Isolating transducer, 1-channel, , Splitter function, Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
IM1-22-R Isolating switching amplifier, 2-channel, , 2 relay outputs (NO), Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), SIL 2, Complete galvanic isolation, Input reverse-polarity protected, TR CU | Turck | Quick Quote | |||
IM33-12EX-HI/24VDC Isolating transducer, 1-channel, , Power supply of 2-wire measuring transducers with HART communication as well as connection to active 2-wire and passive 3-wire transmitters, Input circuit: 0/4…20 mA, Output circuits: 0/4…20 mA, SIL2, Removable terminal blocks, screwable, with 2 mm test box, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, CCEO, Kosha, Installation in zone 2 | Turck | Quick Quote | |||
IM12-FI01-2SF-2I-CPR/24VDC Frequency Transducer/Pulse Counter, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Removable screw terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IMX12-DI01-2S-2T-PR/24VDC Isolating switching amplifier, 2-channel, , 2 transistor outputs (≤ 10kHz), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, Kosha, TIIS, TR CU EAC, DNV, GL, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IM12-DI01-2S-2PP-0/24VDC/CC Isolating switching amplifier, 2-channel, , Two transistor outputs (push-pull), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IM35-11EX-HI Analog Signal Isolator, 1-channel, , Intelligent actuators supplied via HART communication interface, Input circuit: 0/4…20 mA, Output circuit: 0/4…20 mA, intrinsically safe, Universal operating voltage, Complete galvanic isolation, Input reverse-polarity protected, ATEX, TR CU, NEPSI, Installation in zone 2 | Turck | Quick Quote | |||
IMC-AIA-11EX-I/24VDC Isolating transducer, 1-channel, , Isolating transducer, 1-channel, Output circuit: 0/4…20 mA, Complete galvanic isolation, Input reverse-polarity protected, Protection class IP67, Connection with M12 male connectors, ATEX, C, FM, US, IECEx, Use in Zone 2/22 | Turck | Quick Quote | |||
IM12-AI01-1I-2IU-H0/24VDC Isolating transducer, 1-channel, , Splitter function, Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IM73-22EX-R/24VUC Relay coupler, 2-channel, , Relay coupler for switching of intrinsically safe and current limited circuits, High-quality reed relays with rhodium contacts, Switching frequency up to 50 Hz, Galvanic isolation between input and output circuits, ATEX, TR CU, Installation in zone 2 | Turck | Quick Quote | |||
IM12-AI01-1I-2IU-HPR/24VDC/CC Isolating transducer, 1-channel, , Splitter function, Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote |