Isolating transducer, 1-channel, , Splitter function, Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Isolating switching amplifier, 2-channel, , Two transistor outputs (push-pull), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX, IECEx, NEPSI, cUL, cFM INMETRO, Kosha, TR CU EAC, Installation in zone 2, SIL 2
Quick Quote
Isolating transducer, 2-channel, , Power supply of 2-wire measuring transducers with HART communication as well as connection to active 2-wire and passive 3-wire transmitters, Input circuits: 0/4…20 mA, Output circuits: 0/4…20 mA, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, C, FM, US, TR CU, INMETRO, NEPSI, Installation in zone 2
Quick Quote
Isolating switching amplifier, 2-channel, , 2 relay outputs (complementary contact), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Temperature measuring amplifier, 1-channel, , Input circuits monitored for wire break and short circuit, Parameterized via PC, Complete galvanic isolation, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Analog Signal Isolator, 1-channel, , Intelligent actuators supplied via HART communication interface, Input circuit: 0/4…20 mA, Output circuit: 0/4…20 mA, intrinsically safe, SIL2, Removable terminal blocks, screwable, with 2 mm test box, Galvanic isolation of input circuits, output circuits and power supply, ATEX, IECEx, UL, C, FM, US, TR CU, KOSHA, CCOE, Installation in zone 2
Quick Quote
Isolating switching amplifier, 2-channel, , 2 transistor outputs (≤ 10kHz), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Isolating transducer, 1-channel, , Power supply of 2-wire measuring transducers, Input circuit: 0/4…20 mA, Passive output circuit: 0/4…20 mA, Galvanic separation of input circuits, output circuits and power supply, Complete galvanic isolation, Input reverse-polarity protected, Intrinsically safe input circuits EEx ia, Application area acc. to ATEX: II (1) GD
Quick Quote
Coupling Relay, 1-channel, , The inputs are not polarized, Input E1 activates both outputs simultaneously, NE load connection: SIL 3 Safety Function for NE (Normally Energized) load (de-energized in safe state) is available, ND load connection: SIL 3 Safety Function for ND (Normally De-Energized) load (energized in safe state) is available, Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX use in Zone 2, SIL 3
Quick Quote
Isolating switching amplifier, 2-channel, , Output mode NO, Short-circuit protected PNP transistor outputs, Complete galvanic isolation, Input reverse-polarity protected
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
IM12-AI01-1I-2IU-HPR/24VDC Isolating transducer, 1-channel, , Splitter function, Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IMX12-DI01-2S-2PP-0/24VDC Isolating switching amplifier, 2-channel, , Two transistor outputs (push-pull), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX, IECEx, NEPSI, cUL, cFM INMETRO, Kosha, TR CU EAC, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IM33-22EX-HI Isolating transducer, 2-channel, , Power supply of 2-wire measuring transducers with HART communication as well as connection to active 2-wire and passive 3-wire transmitters, Input circuits: 0/4…20 mA, Output circuits: 0/4…20 mA, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, C, FM, US, TR CU, INMETRO, NEPSI, Installation in zone 2 | Turck | Quick Quote | |||
IM12-DI01-2S-2R-PR/24VDC/CC Isolating switching amplifier, 2-channel, , 2 relay outputs (complementary contact), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IM12-TI02-1TCURTDR-1I1R-CPR/24VDC/CC Temperature measuring amplifier, 1-channel, , Input circuits monitored for wire break and short circuit, Parameterized via PC, Complete galvanic isolation, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IM35-11EX-HI/24VDC Analog Signal Isolator, 1-channel, , Intelligent actuators supplied via HART communication interface, Input circuit: 0/4…20 mA, Output circuit: 0/4…20 mA, intrinsically safe, SIL2, Removable terminal blocks, screwable, with 2 mm test box, Galvanic isolation of input circuits, output circuits and power supply, ATEX, IECEx, UL, C, FM, US, TR CU, KOSHA, CCOE, Installation in zone 2 | Turck | Quick Quote | |||
IM12-DI01-2S-2T-PR/24VDC Isolating switching amplifier, 2-channel, , 2 transistor outputs (≤ 10kHz), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
MK33-11EX0-PLI/24VDC Isolating transducer, 1-channel, , Power supply of 2-wire measuring transducers, Input circuit: 0/4…20 mA, Passive output circuit: 0/4…20 mA, Galvanic separation of input circuits, output circuits and power supply, Complete galvanic isolation, Input reverse-polarity protected, Intrinsically safe input circuits EEx ia, Application area acc. to ATEX: II (1) GD | Turck | Quick Quote | |||
IM12-CD01-2R-1U-0/L/CC Coupling Relay, 1-channel, , The inputs are not polarized, Input E1 activates both outputs simultaneously, NE load connection: SIL 3 Safety Function for NE (Normally Energized) load (de-energized in safe state) is available, ND load connection: SIL 3 Safety Function for ND (Normally De-Energized) load (energized in safe state) is available, Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX use in Zone 2, SIL 3 | Turck | Quick Quote | |||
MK1-2AP/24VDC Isolating switching amplifier, 2-channel, , Output mode NO, Short-circuit protected PNP transistor outputs, Complete galvanic isolation, Input reverse-polarity protected | Turck | Quick Quote |