Telemecanique XCKJ10541 is a limit switch with rotary movement and snap action, belonging to the XCKJ sub-range. It features a rated impulse voltage (Uimp) of 6 kV and is constructed with a thermoplastic roller, Zamak head, and Zamak body. This part offers a Pg 13.5 / no 13 cable entry connection type and is protected to a degree of IP66. It is designed for mechanical durability of up to 30,000,000 operations at no load and has 2 poles, including 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The rated insulation voltage (Ui) is 500 V for UL and 300 V, with a control circuit rated current of 3 A at 240Vac (AC-15), 0.27 A at 250Vdc (DC-13), 3 A at 240Vac (A300), and 0.27 A at 250Vdc (Q300). This limit switch operates within a temperature range of -25 °C to 70 °C, has an electrical durability of 5,000,000 operations with load at 240Vac/250Vdc, and requires an operating torque of 0.25 N.m.
Quick Quote
Telemecanique XCKJ10511 is a limit switch with rotary movement and snap action, belonging to the XCKJ sub-range. It features a rated impulse voltage (Uimp) of 6 kV and is constructed with a thermoplastic roller, Zamak head, and Zamak body. This part offers a Pg 13.5 / no 13 cable entry connection type and is protected to a degree of IP66. It is designed for 30,000,000 mechanical operations at no load and has 2 poles, including 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The rated insulation voltage (Ui) is 500 V for UL and 300 V, with a control circuit rated current of 3 A at 240Vac (AC-15), 0.27 A at 250Vdc (DC-13), 3 A at 240Vac (A300), and 0.27 A at 250Vdc (Q300). This limit switch operates within a temperature range of -25 °C to 70 °C, has an electrical durability of 5,000,000 operations with load at 240Vac/250Vdc, and requires an operating torque of 0.25 N.m.
Quick Quote
Telemecanique XE2NP2141 is a limit switch from the XC sub-range, featuring a switch contact block with simultaneous/slow break functionality. It is equipped with 2 poles and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and it has a rated insulation voltage (Ui) of 500 V for UL applications and 300 V otherwise. The control circuit rated current is 3 A for 240Vac (AC-15) and 0.27 A for 250Vdc (DC-13), with similar ratings for A300 and Q300 conditions. This part operates within a temperature range of -25 °C to 70 °C.
Quick Quote
Telemecanique XZCP1164L5 is a pre-wired female M12 connector cable designed for use within the XCMD range. It features a straight M12 connector shape and is equipped with a 5-pin configuration. The cable has a total length of 5 meters.
Quick Quote
Telemecanique ZCEF0 is a limit switch head from the XCMD sub-range, designed for use with M12 fixing nuts. This switch head features a metal plunger and a Zamak head, ensuring durability. It is engineered to operate within a temperature range of -25°C to 70°C.
Quick Quote
Telemecanique ZCKE61 is a metal plunger limit switch head designed for use within the XCKJ range. This switch head operates effectively within a temperature range of -25°C to 70°C.
Quick Quote
Telemecanique ZCY91, part of the XCMD sub-range, is a limit switch featuring a switch lever mechanism. It is constructed with a metal rod and a Zamak head, ensuring durability. This component is designed to operate within a temperature range of -25 °C to 70 °C.
Quick Quote
Telemecanique ZCY59 is a limit switch lever that falls under the XCMD sub-range. It features a switch lever function with a rod made of thermoplastic and a head constructed from Zamak. The lever has a diameter of 6 mm and a length of 200 mm. It is designed to operate within a temperature range of -25 °C to 70 °C.
Quick Quote
Telemecanique ZCPEG13 is a cable gland designed for use with the XCKP range, featuring a plastic body and a connection type of Pg 13.5 / no 13 cable entry. Its main function is to provide cable gland entry, ensuring compatibility and straightforward integration with related components.
Quick Quote
Telemecanique ZCPEG11 is a cable gland designed for use with the XCKP range, featuring a Pg 11 / no 11 cable entry connection type. It is constructed from plastic, specifically for the body of the cable gland, facilitating cable gland entry functions.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
XCKJ10541 Telemecanique XCKJ10541 is a limit switch with rotary movement and snap action, belonging to the XCKJ sub-range. It features a rated impulse voltage (Uimp) of 6 kV and is constructed with a thermoplastic roller, Zamak head, and Zamak body. This part offers a Pg 13.5 / no 13 cable entry connection type and is protected to a degree of IP66. It is designed for mechanical durability of up to 30,000,000 operations at no load and has 2 poles, including 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The rated insulation voltage (Ui) is 500 V for UL and 300 V, with a control circuit rated current of 3 A at 240Vac (AC-15), 0.27 A at 250Vdc (DC-13), 3 A at 240Vac (A300), and 0.27 A at 250Vdc (Q300). This limit switch operates within a temperature range of -25 °C to 70 °C, has an electrical durability of 5,000,000 operations with load at 240Vac/250Vdc, and requires an operating torque of 0.25 N.m. | Telemecanique Sensors | Quick Quote | |||
XCKJ10511 Telemecanique XCKJ10511 is a limit switch with rotary movement and snap action, belonging to the XCKJ sub-range. It features a rated impulse voltage (Uimp) of 6 kV and is constructed with a thermoplastic roller, Zamak head, and Zamak body. This part offers a Pg 13.5 / no 13 cable entry connection type and is protected to a degree of IP66. It is designed for 30,000,000 mechanical operations at no load and has 2 poles, including 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The rated insulation voltage (Ui) is 500 V for UL and 300 V, with a control circuit rated current of 3 A at 240Vac (AC-15), 0.27 A at 250Vdc (DC-13), 3 A at 240Vac (A300), and 0.27 A at 250Vdc (Q300). This limit switch operates within a temperature range of -25 °C to 70 °C, has an electrical durability of 5,000,000 operations with load at 240Vac/250Vdc, and requires an operating torque of 0.25 N.m. | Telemecanique Sensors | Quick Quote | |||
XE2NP2141 Telemecanique XE2NP2141 is a limit switch from the XC sub-range, featuring a switch contact block with simultaneous/slow break functionality. It is equipped with 2 poles and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and it has a rated insulation voltage (Ui) of 500 V for UL applications and 300 V otherwise. The control circuit rated current is 3 A for 240Vac (AC-15) and 0.27 A for 250Vdc (DC-13), with similar ratings for A300 and Q300 conditions. This part operates within a temperature range of -25 °C to 70 °C. | Telemecanique Sensors | Quick Quote | |||
XZCP1164L5 Telemecanique XZCP1164L5 is a pre-wired female M12 connector cable designed for use within the XCMD range. It features a straight M12 connector shape and is equipped with a 5-pin configuration. The cable has a total length of 5 meters. | Telemecanique Sensors | Quick Quote | |||
ZCEF0 Telemecanique ZCEF0 is a limit switch head from the XCMD sub-range, designed for use with M12 fixing nuts. This switch head features a metal plunger and a Zamak head, ensuring durability. It is engineered to operate within a temperature range of -25°C to 70°C. | Telemecanique Sensors | Quick Quote | |||
ZCKE61 Telemecanique ZCKE61 is a metal plunger limit switch head designed for use within the XCKJ range. This switch head operates effectively within a temperature range of -25°C to 70°C. | Telemecanique Sensors | Quick Quote | |||
ZCY91 Telemecanique ZCY91, part of the XCMD sub-range, is a limit switch featuring a switch lever mechanism. It is constructed with a metal rod and a Zamak head, ensuring durability. This component is designed to operate within a temperature range of -25 °C to 70 °C. | Telemecanique Sensors | Quick Quote | |||
ZCY59 Telemecanique ZCY59 is a limit switch lever that falls under the XCMD sub-range. It features a switch lever function with a rod made of thermoplastic and a head constructed from Zamak. The lever has a diameter of 6 mm and a length of 200 mm. It is designed to operate within a temperature range of -25 °C to 70 °C. | Telemecanique Sensors | Quick Quote | |||
ZCPEG13 Telemecanique ZCPEG13 is a cable gland designed for use with the XCKP range, featuring a plastic body and a connection type of Pg 13.5 / no 13 cable entry. Its main function is to provide cable gland entry, ensuring compatibility and straightforward integration with related components. | Telemecanique Sensors | Quick Quote | |||
ZCPEG11 Telemecanique ZCPEG11 is a cable gland designed for use with the XCKP range, featuring a Pg 11 / no 11 cable entry connection type. It is constructed from plastic, specifically for the body of the cable gland, facilitating cable gland entry functions. | Telemecanique Sensors | Quick Quote |