ZCMD61M12 Telemecanique Sensors Limit Switches

Telemecanique Sensors ZCMD61M12 Telemecanique ZCMD61M12 is a limit switch body from the XCMD sub-range, featuring a switch body plus contact assembly with snap action. It is constructed from Zamak for the body and includes an M12 connector for connections. This part is designed with 4-pin circuits and has 1 pole. The contact type is 1C/O - SPDT (Single Pole Double Throw). It has a rated impulse voltage (Uimp) of 4 kV and a rated insulation voltage (Ui) of 400 V according to UL standards and 300 V. The control circuit rated current is 1.5 A for 240Vac (AC-15), 100mA / 0.1 A for 250Vdc (DC-13), 1.5 A for 240Vac (B300), and 100mA / 0.1 A for 250Vdc (R300). The operating temperature range is from -25 °C to 70 °C.
Telemecanique Sensors

Part#:ZCMD61M12

Manufacturer:Telemecanique Sensors

Product Lifecycle:Active

Get a quick Quote!

Telemecanique ZCMD61M12 is a limit switch body from the XCMD sub-range, featuring a switch body plus contact assembly with snap action. It is constructed from Zamak for the body and includes an M12 connector for connections. This part is designed with 4-pin circuits and has 1 pole. The contact type is 1C/O - SPDT (Single Pole Double Throw). It has a rated impulse voltage (Uimp) of 4 kV and a rated insulation voltage (Ui) of 400 V according to UL standards and 300 V. The control circuit rated current is 1.5 A for 240Vac (AC-15), 100mA / 0.1 A for 250Vdc (DC-13), 1.5 A for 240Vac (B300), and 100mA / 0.1 A for 250Vdc (R300). The operating temperature range is from -25 °C to 70 °C.

About the manufacturer: Telemecanique Sensors is one of the manufacturers that offers Limit Switches that you can order at Powermatic Associates site. For more than forty years, Telemecanique Sensors, formerly Hyde Park, has been refining ultrasonic technology and has become a leading global provider in this industry. Through the use of advanced ultrasonic technology, Telemecanique designs and manufactures reliable noncontact sensors.

Check out the ZCMD61M12 Telemecanique Sensors price in the box on the right side or send a quick quote.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


ZCMD61M12 Description

Telemecanique ZCMD61M12 is a limit switch body from the XCMD sub-range, featuring a switch body plus contact assembly with snap action. It is constructed from Zamak for the body and includes an M12 connector for connections. This part is designed with 4-pin circuits and has 1 pole. The contact type is 1C/O - SPDT (Single Pole Double Throw). It has a rated impulse voltage (Uimp) of 4 kV and a rated insulation voltage (Ui) of 400 V according to UL standards and 300 V. The control circuit rated current is 1.5 A for 240Vac (AC-15), 100mA / 0.1 A for 250Vdc (DC-13), 1.5 A for 240Vac (B300), and 100mA / 0.1 A for 250Vdc (R300). The operating temperature range is from -25 °C to 70 °C.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1